Capacity Utilization Factor (CUF) of the 70kW on-grid solar station in the dry climate of Termez

The aim of the present study was to assess the installed capacity utilization factor and the suitability of a 70kW photovoltaic plant placed on the roof of a dormitory located at Termez city (Termez state university). We can report the energy to production directly through mobile devices. CUF is one...

Full description

Bibliographic Details
Main Authors: Tursunov M. N., Sabirov Kh., Axtamov T. Z., Abdiyev U. B., Chariyev M. M., Yuldoshov B. A., Toshpulatov S. F.
Format: Article
Language:English
Published: EDP Sciences 2023-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/38/e3sconf_conmechydro23_02059.pdf
_version_ 1797775913116499968
author Tursunov M. N.
Sabirov Kh.
Axtamov T. Z.
Abdiyev U. B.
Chariyev M. M.
Yuldoshov B. A.
Toshpulatov S. F.
author_facet Tursunov M. N.
Sabirov Kh.
Axtamov T. Z.
Abdiyev U. B.
Chariyev M. M.
Yuldoshov B. A.
Toshpulatov S. F.
author_sort Tursunov M. N.
collection DOAJ
description The aim of the present study was to assess the installed capacity utilization factor and the suitability of a 70kW photovoltaic plant placed on the roof of a dormitory located at Termez city (Termez state university). We can report the energy to production directly through mobile devices. CUF is one of the quantities that shows the performance quality of each power generating station. The results of our research cover two months autumn and winter. Through this, the theoretically estimated minimum values of CUF on the least sunny days have also been proven in real values. It is estimated that the annual result of this value will be around 15%-20%. Because in the winter months, the value of individual CUF on open days increases by 20%. An estimated 15.68 mln kg of CO2 was avoided due to the generation of 22.4MWh of energy. This is a small improvement in the environment and energy sector.
first_indexed 2024-03-12T22:42:28Z
format Article
id doaj.art-a1c6fdae0f724d529ef0ac9acd65674e
institution Directory Open Access Journal
issn 2267-1242
language English
last_indexed 2024-03-12T22:42:28Z
publishDate 2023-01-01
publisher EDP Sciences
record_format Article
series E3S Web of Conferences
spelling doaj.art-a1c6fdae0f724d529ef0ac9acd65674e2023-07-21T09:35:09ZengEDP SciencesE3S Web of Conferences2267-12422023-01-014010205910.1051/e3sconf/202340102059e3sconf_conmechydro23_02059Capacity Utilization Factor (CUF) of the 70kW on-grid solar station in the dry climate of TermezTursunov M. N.0Sabirov Kh.1Axtamov T. Z.2Abdiyev U. B.3Chariyev M. M.4Yuldoshov B. A.5Toshpulatov S. F.6Physical-Technical Institute of Academy of Sciences of the Republic of UzbekistanPhysical-Technical Institute of Academy of Sciences of the Republic of UzbekistanPhysical-Technical Institute of Academy of Sciences of the Republic of UzbekistanTermiz State UniversityTermiz State UniversityTermiz State UniversityTermiz State UniversityThe aim of the present study was to assess the installed capacity utilization factor and the suitability of a 70kW photovoltaic plant placed on the roof of a dormitory located at Termez city (Termez state university). We can report the energy to production directly through mobile devices. CUF is one of the quantities that shows the performance quality of each power generating station. The results of our research cover two months autumn and winter. Through this, the theoretically estimated minimum values of CUF on the least sunny days have also been proven in real values. It is estimated that the annual result of this value will be around 15%-20%. Because in the winter months, the value of individual CUF on open days increases by 20%. An estimated 15.68 mln kg of CO2 was avoided due to the generation of 22.4MWh of energy. This is a small improvement in the environment and energy sector.https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/38/e3sconf_conmechydro23_02059.pdf
spellingShingle Tursunov M. N.
Sabirov Kh.
Axtamov T. Z.
Abdiyev U. B.
Chariyev M. M.
Yuldoshov B. A.
Toshpulatov S. F.
Capacity Utilization Factor (CUF) of the 70kW on-grid solar station in the dry climate of Termez
E3S Web of Conferences
title Capacity Utilization Factor (CUF) of the 70kW on-grid solar station in the dry climate of Termez
title_full Capacity Utilization Factor (CUF) of the 70kW on-grid solar station in the dry climate of Termez
title_fullStr Capacity Utilization Factor (CUF) of the 70kW on-grid solar station in the dry climate of Termez
title_full_unstemmed Capacity Utilization Factor (CUF) of the 70kW on-grid solar station in the dry climate of Termez
title_short Capacity Utilization Factor (CUF) of the 70kW on-grid solar station in the dry climate of Termez
title_sort capacity utilization factor cuf of the 70kw on grid solar station in the dry climate of termez
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/38/e3sconf_conmechydro23_02059.pdf
work_keys_str_mv AT tursunovmn capacityutilizationfactorcufofthe70kwongridsolarstationinthedryclimateoftermez
AT sabirovkh capacityutilizationfactorcufofthe70kwongridsolarstationinthedryclimateoftermez
AT axtamovtz capacityutilizationfactorcufofthe70kwongridsolarstationinthedryclimateoftermez
AT abdiyevub capacityutilizationfactorcufofthe70kwongridsolarstationinthedryclimateoftermez
AT chariyevmm capacityutilizationfactorcufofthe70kwongridsolarstationinthedryclimateoftermez
AT yuldoshovba capacityutilizationfactorcufofthe70kwongridsolarstationinthedryclimateoftermez
AT toshpulatovsf capacityutilizationfactorcufofthe70kwongridsolarstationinthedryclimateoftermez