Application of piecewise VMAT technique to whole-brain radiotherapy with simultaneous integrated boost for multiple metastases

Abstract Purpose This study implemented a piecewise volumetric modulated arc therapy (P-VMAT) for realizing whole-brain radiation therapy (WBRT) with simultaneous integrated boost (SIB) for multiple brain metastases (> 40 metastases) with a conventional C-arm linear accelerator. Materials and met...

Full description

Bibliographic Details
Main Authors: Yuan Xu, Yingjie Xu, Kuo Men, Jianping Xiao, Jianrong Dai
Format: Article
Language:English
Published: BMC 2022-05-01
Series:Radiation Oncology
Subjects:
Online Access:https://doi.org/10.1186/s13014-022-02059-6
_version_ 1811304800084557824
author Yuan Xu
Yingjie Xu
Kuo Men
Jianping Xiao
Jianrong Dai
author_facet Yuan Xu
Yingjie Xu
Kuo Men
Jianping Xiao
Jianrong Dai
author_sort Yuan Xu
collection DOAJ
description Abstract Purpose This study implemented a piecewise volumetric modulated arc therapy (P-VMAT) for realizing whole-brain radiation therapy (WBRT) with simultaneous integrated boost (SIB) for multiple brain metastases (> 40 metastases) with a conventional C-arm linear accelerator. Materials and methods This study retrospectively analyzed 10 patients with multiple brain metastases (40–120 metastases, median 76), who underwent WBRT and SIB using helical tomotherapy (HT). The prescribed doses were 40 Gy/20 f and 60 Gy/20 f for WBRT and SIB, respectively. Corresponding new HT plans were designed with P-VMAT using 7 arcs. For each arc, the collimator was rotated to 45°, and the field width was limited to 2.5 cm with 0.5 cm overlap with adjacent arcs. Thus, each arc covered only one section of the brain target volume. A conventional dual arc VMAT (DA-VMAT) plan was also designed. HT, P-VMAT, and DA-VMAT plans were compared using dose distribution reviews and dosimetric parameters. ArcCHECK phantom measurements were performed for verification of P-VMAT plans. Results No significant differences in the mean coverage of the whole-brain target and metastases were observed between HT and P-VMAT (p > 0.05). The conformity index for the whole-brain target improved with P-VMAT compared with HT (p < 0.05). Furthermore, the volume of 44 Gy V44 (110% of prescribed dose for WBRT) received for whole-brain significantly reduced with P-VMAT from 38.2 ± 12.9% to 23.3 ± 9.4% (p < 0.05), and the maximum dose for organs at risks such as the hippocampus, optical nerve, optical chiasm, and spinal cord declined with P-VMAT (p < 0.05). Unlike HT and P-VMAT, DA-VMAT was clinically unacceptable because V44 in the whole-brain was too high (54.7 ± 8.2%). The mean absolute dose gamma passing rate for P-VMAT plans was 97.6 ± 1.1% (3%/3 mm criterion, 10%). Conclusions P-VMAT is favorable for WBRT and SIB for multiple brain metastases. It provides comparable coverage of whole-brain target and SIB, with better conformity, lower V44, and better dose sparing of organs at risk compared with HT. Furthermore, results show that DA-VMAT fails clinical practice even for a relatively large number of brain metastases with a high degree of plan complexity. The patient specific verification demonstrates the feasibility of P-VMAT for clinical application.
first_indexed 2024-04-13T08:13:46Z
format Article
id doaj.art-a20648f97fa742b2a1fcdab72fc07646
institution Directory Open Access Journal
issn 1748-717X
language English
last_indexed 2024-04-13T08:13:46Z
publishDate 2022-05-01
publisher BMC
record_format Article
series Radiation Oncology
spelling doaj.art-a20648f97fa742b2a1fcdab72fc076462022-12-22T02:54:52ZengBMCRadiation Oncology1748-717X2022-05-011711910.1186/s13014-022-02059-6Application of piecewise VMAT technique to whole-brain radiotherapy with simultaneous integrated boost for multiple metastasesYuan Xu0Yingjie Xu1Kuo Men2Jianping Xiao3Jianrong Dai4Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical CollegeDepartment of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical CollegeDepartment of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical CollegeDepartment of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical CollegeDepartment of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical CollegeAbstract Purpose This study implemented a piecewise volumetric modulated arc therapy (P-VMAT) for realizing whole-brain radiation therapy (WBRT) with simultaneous integrated boost (SIB) for multiple brain metastases (> 40 metastases) with a conventional C-arm linear accelerator. Materials and methods This study retrospectively analyzed 10 patients with multiple brain metastases (40–120 metastases, median 76), who underwent WBRT and SIB using helical tomotherapy (HT). The prescribed doses were 40 Gy/20 f and 60 Gy/20 f for WBRT and SIB, respectively. Corresponding new HT plans were designed with P-VMAT using 7 arcs. For each arc, the collimator was rotated to 45°, and the field width was limited to 2.5 cm with 0.5 cm overlap with adjacent arcs. Thus, each arc covered only one section of the brain target volume. A conventional dual arc VMAT (DA-VMAT) plan was also designed. HT, P-VMAT, and DA-VMAT plans were compared using dose distribution reviews and dosimetric parameters. ArcCHECK phantom measurements were performed for verification of P-VMAT plans. Results No significant differences in the mean coverage of the whole-brain target and metastases were observed between HT and P-VMAT (p > 0.05). The conformity index for the whole-brain target improved with P-VMAT compared with HT (p < 0.05). Furthermore, the volume of 44 Gy V44 (110% of prescribed dose for WBRT) received for whole-brain significantly reduced with P-VMAT from 38.2 ± 12.9% to 23.3 ± 9.4% (p < 0.05), and the maximum dose for organs at risks such as the hippocampus, optical nerve, optical chiasm, and spinal cord declined with P-VMAT (p < 0.05). Unlike HT and P-VMAT, DA-VMAT was clinically unacceptable because V44 in the whole-brain was too high (54.7 ± 8.2%). The mean absolute dose gamma passing rate for P-VMAT plans was 97.6 ± 1.1% (3%/3 mm criterion, 10%). Conclusions P-VMAT is favorable for WBRT and SIB for multiple brain metastases. It provides comparable coverage of whole-brain target and SIB, with better conformity, lower V44, and better dose sparing of organs at risk compared with HT. Furthermore, results show that DA-VMAT fails clinical practice even for a relatively large number of brain metastases with a high degree of plan complexity. The patient specific verification demonstrates the feasibility of P-VMAT for clinical application.https://doi.org/10.1186/s13014-022-02059-6Piecewise VMATWBRTSIBBrain metastasesHT
spellingShingle Yuan Xu
Yingjie Xu
Kuo Men
Jianping Xiao
Jianrong Dai
Application of piecewise VMAT technique to whole-brain radiotherapy with simultaneous integrated boost for multiple metastases
Radiation Oncology
Piecewise VMAT
WBRT
SIB
Brain metastases
HT
title Application of piecewise VMAT technique to whole-brain radiotherapy with simultaneous integrated boost for multiple metastases
title_full Application of piecewise VMAT technique to whole-brain radiotherapy with simultaneous integrated boost for multiple metastases
title_fullStr Application of piecewise VMAT technique to whole-brain radiotherapy with simultaneous integrated boost for multiple metastases
title_full_unstemmed Application of piecewise VMAT technique to whole-brain radiotherapy with simultaneous integrated boost for multiple metastases
title_short Application of piecewise VMAT technique to whole-brain radiotherapy with simultaneous integrated boost for multiple metastases
title_sort application of piecewise vmat technique to whole brain radiotherapy with simultaneous integrated boost for multiple metastases
topic Piecewise VMAT
WBRT
SIB
Brain metastases
HT
url https://doi.org/10.1186/s13014-022-02059-6
work_keys_str_mv AT yuanxu applicationofpiecewisevmattechniquetowholebrainradiotherapywithsimultaneousintegratedboostformultiplemetastases
AT yingjiexu applicationofpiecewisevmattechniquetowholebrainradiotherapywithsimultaneousintegratedboostformultiplemetastases
AT kuomen applicationofpiecewisevmattechniquetowholebrainradiotherapywithsimultaneousintegratedboostformultiplemetastases
AT jianpingxiao applicationofpiecewisevmattechniquetowholebrainradiotherapywithsimultaneousintegratedboostformultiplemetastases
AT jianrongdai applicationofpiecewisevmattechniquetowholebrainradiotherapywithsimultaneousintegratedboostformultiplemetastases