Theoretical analysis based on CFD method for evaluation of Pd-Ag Membrane reactor performance in comparison with conventional reactor during dehydrogenation of cyclohexane

In the present study, the performance of the palladium-silver membrane reactor during the cyclohexane dehydrogenation (DCH) reaction is modeled and simulated based on the computational fluid dynamics (CFD) method. In recent years, hydrogen production has been important due to its industrial applicat...

Full description

Bibliographic Details
Main Authors: kamran ghasemzadeh, Milad Ghahremani
Format: Article
Language:fas
Published: Semnan University 2020-05-01
Series:مجله مدل سازی در مهندسی
Subjects:
Online Access:https://modelling.semnan.ac.ir/article_4498_a4f10b12f01e55aece19e589d88a047d.pdf
_version_ 1797296548787257344
author kamran ghasemzadeh
Milad Ghahremani
author_facet kamran ghasemzadeh
Milad Ghahremani
author_sort kamran ghasemzadeh
collection DOAJ
description In the present study, the performance of the palladium-silver membrane reactor during the cyclohexane dehydrogenation (DCH) reaction is modeled and simulated based on the computational fluid dynamics (CFD) method. In recent years, hydrogen production has been important due to its industrial applications and clean energy. Therefore, the dehydrogenation process of cyclohexane has been considered due to the production of crude dioxide and crane monoxide-free hydrogen as well as high hydrogen capacity. For this purpose, a symmetric two-dimensional model is proposed for the palladium membrane reactor. In this regard, after modeling and simulating the performance of the fixed bed reactor and comparing its results with the laboratory data, a good agreement (4% error) was obtained between theoretical and laboratory results. In order to better understand the performance of the membrane reactor during the DCH reaction, the influence of various operating parameters (reaction temperature, reaction pressure, adsorption factor and flow arrangement) on the concepts of cyclohexane conversion percentage and hydrogen recovery percentage have been investigated. As a general result in all operating conditions, the PdC membrane reactor (MRC) showed better performance than the synchronous flow membrane reactor (MR) and conventional fixed bed reactor (TR). For example, the cyclohexane conversion rate increased with increasing temperature from 430 to 490 K, for MRC reactor from 28.4 to 100%, MR reactor from 10.1 to 77.75 and TR reactor from 7.42 to 46.29.
first_indexed 2024-03-07T22:06:21Z
format Article
id doaj.art-a2108429e4aa4aae83d0549a4466e489
institution Directory Open Access Journal
issn 2008-4854
2783-2538
language fas
last_indexed 2024-03-07T22:06:21Z
publishDate 2020-05-01
publisher Semnan University
record_format Article
series مجله مدل سازی در مهندسی
spelling doaj.art-a2108429e4aa4aae83d0549a4466e4892024-02-23T19:07:14ZfasSemnan Universityمجله مدل سازی در مهندسی2008-48542783-25382020-05-01186021722610.22075/jme.2020.18801.17824498Theoretical analysis based on CFD method for evaluation of Pd-Ag Membrane reactor performance in comparison with conventional reactor during dehydrogenation of cyclohexanekamran ghasemzadeh0Milad Ghahremani1chemical engineering department, Urmia university of technology, Urmia, West Azerbaijan, IranChemical engineering faculty, Urmia university of thechnology, Urmia, IranIn the present study, the performance of the palladium-silver membrane reactor during the cyclohexane dehydrogenation (DCH) reaction is modeled and simulated based on the computational fluid dynamics (CFD) method. In recent years, hydrogen production has been important due to its industrial applications and clean energy. Therefore, the dehydrogenation process of cyclohexane has been considered due to the production of crude dioxide and crane monoxide-free hydrogen as well as high hydrogen capacity. For this purpose, a symmetric two-dimensional model is proposed for the palladium membrane reactor. In this regard, after modeling and simulating the performance of the fixed bed reactor and comparing its results with the laboratory data, a good agreement (4% error) was obtained between theoretical and laboratory results. In order to better understand the performance of the membrane reactor during the DCH reaction, the influence of various operating parameters (reaction temperature, reaction pressure, adsorption factor and flow arrangement) on the concepts of cyclohexane conversion percentage and hydrogen recovery percentage have been investigated. As a general result in all operating conditions, the PdC membrane reactor (MRC) showed better performance than the synchronous flow membrane reactor (MR) and conventional fixed bed reactor (TR). For example, the cyclohexane conversion rate increased with increasing temperature from 430 to 490 K, for MRC reactor from 28.4 to 100%, MR reactor from 10.1 to 77.75 and TR reactor from 7.42 to 46.29.https://modelling.semnan.ac.ir/article_4498_a4f10b12f01e55aece19e589d88a047d.pdfmodeling and simulationpalladium membrane reactordehydrogenationcyclohexanehydrogen production
spellingShingle kamran ghasemzadeh
Milad Ghahremani
Theoretical analysis based on CFD method for evaluation of Pd-Ag Membrane reactor performance in comparison with conventional reactor during dehydrogenation of cyclohexane
مجله مدل سازی در مهندسی
modeling and simulation
palladium membrane reactor
dehydrogenation
cyclohexane
hydrogen production
title Theoretical analysis based on CFD method for evaluation of Pd-Ag Membrane reactor performance in comparison with conventional reactor during dehydrogenation of cyclohexane
title_full Theoretical analysis based on CFD method for evaluation of Pd-Ag Membrane reactor performance in comparison with conventional reactor during dehydrogenation of cyclohexane
title_fullStr Theoretical analysis based on CFD method for evaluation of Pd-Ag Membrane reactor performance in comparison with conventional reactor during dehydrogenation of cyclohexane
title_full_unstemmed Theoretical analysis based on CFD method for evaluation of Pd-Ag Membrane reactor performance in comparison with conventional reactor during dehydrogenation of cyclohexane
title_short Theoretical analysis based on CFD method for evaluation of Pd-Ag Membrane reactor performance in comparison with conventional reactor during dehydrogenation of cyclohexane
title_sort theoretical analysis based on cfd method for evaluation of pd ag membrane reactor performance in comparison with conventional reactor during dehydrogenation of cyclohexane
topic modeling and simulation
palladium membrane reactor
dehydrogenation
cyclohexane
hydrogen production
url https://modelling.semnan.ac.ir/article_4498_a4f10b12f01e55aece19e589d88a047d.pdf
work_keys_str_mv AT kamranghasemzadeh theoreticalanalysisbasedoncfdmethodforevaluationofpdagmembranereactorperformanceincomparisonwithconventionalreactorduringdehydrogenationofcyclohexane
AT miladghahremani theoreticalanalysisbasedoncfdmethodforevaluationofpdagmembranereactorperformanceincomparisonwithconventionalreactorduringdehydrogenationofcyclohexane