Optimal Cooling Load and COP Relationship of a Four-Heat-Reservoir Endoreversible Absorption Refrigeration Cycle
Abstract: On the basis of a four-heat-reservoir endoreversible absorption refrigeration cycle model, another linear heat transfer law [i.e., the heat-flux] is adopted, the fundamental optimal relation between the coefficient of performance (COP) and the cooling load, as well as the maximum cooling l...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2004-06-01
|
Series: | Entropy |
Subjects: | |
Online Access: | http://www.mdpi.com/1099-4300/6/3/316/ |
_version_ | 1798034260614971392 |
---|---|
author | Chih Wu Fengrui Sun Tong Zheng Lingen Chen |
author_facet | Chih Wu Fengrui Sun Tong Zheng Lingen Chen |
author_sort | Chih Wu |
collection | DOAJ |
description | Abstract: On the basis of a four-heat-reservoir endoreversible absorption refrigeration cycle model, another linear heat transfer law [i.e., the heat-flux] is adopted, the fundamental optimal relation between the coefficient of performance (COP) and the cooling load, as well as the maximum cooling load and the corresponding COP of the cycle coupled to constant-temperature heat reservoirs are derived by using finite-time thermodynamics or thermodynamic optimization. The optimal distribution of the heat-transfer surface areas is also obtained. Moreover, the effects of the cycle parameters on the COP and the cooling load of the cycle are studied by detailed numerical examples. The results obtained herein are of importance to the optimal design and performance improvement of an absorption refrigeration cycle. |
first_indexed | 2024-04-11T20:41:54Z |
format | Article |
id | doaj.art-a26e32dee5354fb1830c490567163714 |
institution | Directory Open Access Journal |
issn | 1099-4300 |
language | English |
last_indexed | 2024-04-11T20:41:54Z |
publishDate | 2004-06-01 |
publisher | MDPI AG |
record_format | Article |
series | Entropy |
spelling | doaj.art-a26e32dee5354fb1830c4905671637142022-12-22T04:04:12ZengMDPI AGEntropy1099-43002004-06-016331632610.3390/e6030316Optimal Cooling Load and COP Relationship of a Four-Heat-Reservoir Endoreversible Absorption Refrigeration CycleChih WuFengrui SunTong ZhengLingen ChenAbstract: On the basis of a four-heat-reservoir endoreversible absorption refrigeration cycle model, another linear heat transfer law [i.e., the heat-flux] is adopted, the fundamental optimal relation between the coefficient of performance (COP) and the cooling load, as well as the maximum cooling load and the corresponding COP of the cycle coupled to constant-temperature heat reservoirs are derived by using finite-time thermodynamics or thermodynamic optimization. The optimal distribution of the heat-transfer surface areas is also obtained. Moreover, the effects of the cycle parameters on the COP and the cooling load of the cycle are studied by detailed numerical examples. The results obtained herein are of importance to the optimal design and performance improvement of an absorption refrigeration cycle.http://www.mdpi.com/1099-4300/6/3/316/finite time thermodynamicsthermodynamic optimizationfour-heat-reservoir endoreversible absorption refrigeration cycleoptimal performance |
spellingShingle | Chih Wu Fengrui Sun Tong Zheng Lingen Chen Optimal Cooling Load and COP Relationship of a Four-Heat-Reservoir Endoreversible Absorption Refrigeration Cycle Entropy finite time thermodynamics thermodynamic optimization four-heat-reservoir endoreversible absorption refrigeration cycle optimal performance |
title | Optimal Cooling Load and COP Relationship of a Four-Heat-Reservoir Endoreversible Absorption Refrigeration Cycle |
title_full | Optimal Cooling Load and COP Relationship of a Four-Heat-Reservoir Endoreversible Absorption Refrigeration Cycle |
title_fullStr | Optimal Cooling Load and COP Relationship of a Four-Heat-Reservoir Endoreversible Absorption Refrigeration Cycle |
title_full_unstemmed | Optimal Cooling Load and COP Relationship of a Four-Heat-Reservoir Endoreversible Absorption Refrigeration Cycle |
title_short | Optimal Cooling Load and COP Relationship of a Four-Heat-Reservoir Endoreversible Absorption Refrigeration Cycle |
title_sort | optimal cooling load and cop relationship of a four heat reservoir endoreversible absorption refrigeration cycle |
topic | finite time thermodynamics thermodynamic optimization four-heat-reservoir endoreversible absorption refrigeration cycle optimal performance |
url | http://www.mdpi.com/1099-4300/6/3/316/ |
work_keys_str_mv | AT chihwu optimalcoolingloadandcoprelationshipofafourheatreservoirendoreversibleabsorptionrefrigerationcycle AT fengruisun optimalcoolingloadandcoprelationshipofafourheatreservoirendoreversibleabsorptionrefrigerationcycle AT tongzheng optimalcoolingloadandcoprelationshipofafourheatreservoirendoreversibleabsorptionrefrigerationcycle AT lingenchen optimalcoolingloadandcoprelationshipofafourheatreservoirendoreversibleabsorptionrefrigerationcycle |