Optimization of Parameters in 16-slice CT-‌‌scan Protocols for Reduction of the Absorbed Dose

Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was perfo...

Full description

Bibliographic Details
Main Authors: Shahrokh Naseri, Mahdi Momen Nezhad, Zahra Hozhabri, Abbas Haghparast, Golestan Karami, Peyman Hejazi
Format: Article
Language:English
Published: Mashhad University of Medical Sciences 2014-08-01
Series:Iranian Journal of Medical Physics
Subjects:
Online Access:http://ijmp.mums.ac.ir/article_3101_7eb6d1b9d7e59a94070873878d6ed7a3.pdf
_version_ 1828433133798686720
author Shahrokh Naseri
Mahdi Momen Nezhad
Zahra Hozhabri
Abbas Haghparast
Golestan Karami
Peyman Hejazi
author_facet Shahrokh Naseri
Mahdi Momen Nezhad
Zahra Hozhabri
Abbas Haghparast
Golestan Karami
Peyman Hejazi
author_sort Shahrokh Naseri
collection DOAJ
description Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for the measurement of image-related parameters and CTDI phantom was utilized for the calculation of absorbed dose to patients. Imaging parameters including mA (50-400 mA), pitch factor (1 and 1.5) and rotation time (range of 0.5, 0.75, 1, 1.5 and 2 seconds) were considered as independent variables. The brain, abdomen and chest imaging was performed multi-slice and spiral modes. Changes in image quality parameters including contrast resolution (CR) and spatial resolution (SR) in each condition were measured and determined by MATLAB software. Results After normalizing data by plotting the full width at half maximum (FWHM) of point spread function (PSF) in each condition, it was observed that image quality was not noticeably affected by each cases. Therefore, in brain scan, the lowest patient dose was in 150 mA and rotation time of 1.5 seconds. Based on results of scanning of the abdomen and chest, the lowest patient dose was obtained by 100 mA and pitch factors of 1 and 1.5. Conclusion It was found that images with acceptable quality and reliable detection ability could be obtained using smaller doses of radiation, compared to protocols commonly used by operators.
first_indexed 2024-12-10T18:30:41Z
format Article
id doaj.art-a279b65c1ab7490b8602f2ea022f7450
institution Directory Open Access Journal
issn 2345-3672
2345-3672
language English
last_indexed 2024-12-10T18:30:41Z
publishDate 2014-08-01
publisher Mashhad University of Medical Sciences
record_format Article
series Iranian Journal of Medical Physics
spelling doaj.art-a279b65c1ab7490b8602f2ea022f74502022-12-22T01:37:57ZengMashhad University of Medical SciencesIranian Journal of Medical Physics2345-36722345-36722014-08-0111Issue 2,327027510.22038/ijmp.2014.31013101Optimization of Parameters in 16-slice CT-‌‌scan Protocols for Reduction of the Absorbed DoseShahrokh Naseri0Mahdi Momen Nezhad1Zahra Hozhabri2Abbas Haghparast3Golestan Karami4Peyman Hejazi5Medical Physics Dept., Mashhad University of Medical Sciences, Mashhad,IranMedical Physics Dept., Mashhad University of Medical Sciences, Mashhad,IranMedical Physics Dept., Kermanshah University of Medical Sciences, Kermanshah,IranMedical Physics Dept., Kermanshah University of Medical Sciences, Kermanshah,IranMedical Physics Dept., Kermanshah University of Medical Sciences, Kermanshah,IranMedical Physics Dept., Semnan University of Medical Sciences, Semnan, IranIntroduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for the measurement of image-related parameters and CTDI phantom was utilized for the calculation of absorbed dose to patients. Imaging parameters including mA (50-400 mA), pitch factor (1 and 1.5) and rotation time (range of 0.5, 0.75, 1, 1.5 and 2 seconds) were considered as independent variables. The brain, abdomen and chest imaging was performed multi-slice and spiral modes. Changes in image quality parameters including contrast resolution (CR) and spatial resolution (SR) in each condition were measured and determined by MATLAB software. Results After normalizing data by plotting the full width at half maximum (FWHM) of point spread function (PSF) in each condition, it was observed that image quality was not noticeably affected by each cases. Therefore, in brain scan, the lowest patient dose was in 150 mA and rotation time of 1.5 seconds. Based on results of scanning of the abdomen and chest, the lowest patient dose was obtained by 100 mA and pitch factors of 1 and 1.5. Conclusion It was found that images with acceptable quality and reliable detection ability could be obtained using smaller doses of radiation, compared to protocols commonly used by operators.http://ijmp.mums.ac.ir/article_3101_7eb6d1b9d7e59a94070873878d6ed7a3.pdfComputed Tomography (CT)Absorbed DoseOptimization
spellingShingle Shahrokh Naseri
Mahdi Momen Nezhad
Zahra Hozhabri
Abbas Haghparast
Golestan Karami
Peyman Hejazi
Optimization of Parameters in 16-slice CT-‌‌scan Protocols for Reduction of the Absorbed Dose
Iranian Journal of Medical Physics
Computed Tomography (CT)
Absorbed Dose
Optimization
title Optimization of Parameters in 16-slice CT-‌‌scan Protocols for Reduction of the Absorbed Dose
title_full Optimization of Parameters in 16-slice CT-‌‌scan Protocols for Reduction of the Absorbed Dose
title_fullStr Optimization of Parameters in 16-slice CT-‌‌scan Protocols for Reduction of the Absorbed Dose
title_full_unstemmed Optimization of Parameters in 16-slice CT-‌‌scan Protocols for Reduction of the Absorbed Dose
title_short Optimization of Parameters in 16-slice CT-‌‌scan Protocols for Reduction of the Absorbed Dose
title_sort optimization of parameters in 16 slice ct ‌‌scan protocols for reduction of the absorbed dose
topic Computed Tomography (CT)
Absorbed Dose
Optimization
url http://ijmp.mums.ac.ir/article_3101_7eb6d1b9d7e59a94070873878d6ed7a3.pdf
work_keys_str_mv AT shahrokhnaseri optimizationofparametersin16slicectscanprotocolsforreductionoftheabsorbeddose
AT mahdimomennezhad optimizationofparametersin16slicectscanprotocolsforreductionoftheabsorbeddose
AT zahrahozhabri optimizationofparametersin16slicectscanprotocolsforreductionoftheabsorbeddose
AT abbashaghparast optimizationofparametersin16slicectscanprotocolsforreductionoftheabsorbeddose
AT golestankarami optimizationofparametersin16slicectscanprotocolsforreductionoftheabsorbeddose
AT peymanhejazi optimizationofparametersin16slicectscanprotocolsforreductionoftheabsorbeddose