Automatic tuning of arc-extinguishing reactors for a medium-voltage power system 6-35 kV applying the method of two frequencies auxiliary currents overlap

The urgency of the discussed issue is caused by the need to control automatic tuning of the arc-extinguishing reactor in a medium-voltage power system. Full effect of the application of such reactors takes place in the case if ARC-extinguishing reactor is automatically adjusted coils in resonance wi...

Full description

Bibliographic Details
Main Authors: Robert Vaynshteyn, Vera Shestakova, Sergey Pashkovskiy, Svyatoslav Yudin, Aleksey Serbulov
Format: Article
Language:Russian
Published: Tomsk Polytechnic University 2019-05-01
Series:Известия Томского политехнического университета: Инжиниринг георесурсов
Subjects:
Online Access:http://izvestiya-tpu.ru/archive/article/view/1473
_version_ 1797812528123740160
author Robert Vaynshteyn
Vera Shestakova
Sergey Pashkovskiy
Svyatoslav Yudin
Aleksey Serbulov
author_facet Robert Vaynshteyn
Vera Shestakova
Sergey Pashkovskiy
Svyatoslav Yudin
Aleksey Serbulov
author_sort Robert Vaynshteyn
collection DOAJ
description The urgency of the discussed issue is caused by the need to control automatic tuning of the arc-extinguishing reactor in a medium-voltage power system. Full effect of the application of such reactors takes place in the case if ARC-extinguishing reactor is automatically adjusted coils in resonance with the network total capacity. To realize automatic adjustment it is necessary to obtain continuously the information on deviation from resonance in the form of electrical signal. The main aim of the research is to design the method for controlling arc-extinguishing reactor adjustment in medium-voltage power systems, based on superposition of two different non-industrial frequencies currents. Typical high-voltage electrical equipment can be used for the design. Investigation methods: mathematical modeling with software packages MATHCAD, MATLAB. Results: It is shown that the method proposed is sensitive enough to small changes in detuning of the capacitive earth fault currents. The authors have determined that currents could be input into the network through the winding of a conventional voltage transformer connected by open delta. The absolute methodical error of the compensation detuning measurements was calculated. It is caused by conductance in a zero sequence circuit. It was proved that typically absolute methodical error does not exceed 0,002. The paper introduces the algorithms of processing electrical quantities with frequencies of superimposed currents when the electric signal characterizing compensation detuning does not depend on absolute values of network total capacitive current.
first_indexed 2024-03-13T07:38:52Z
format Article
id doaj.art-a2a7b7c08d914ee193a100f9971f6e72
institution Directory Open Access Journal
issn 2500-1019
2413-1830
language Russian
last_indexed 2024-03-13T07:38:52Z
publishDate 2019-05-01
publisher Tomsk Polytechnic University
record_format Article
series Известия Томского политехнического университета: Инжиниринг георесурсов
spelling doaj.art-a2a7b7c08d914ee193a100f9971f6e722023-06-03T21:07:53ZrusTomsk Polytechnic UniversityИзвестия Томского политехнического университета: Инжиниринг георесурсов2500-10192413-18302019-05-013254Automatic tuning of arc-extinguishing reactors for a medium-voltage power system 6-35 kV applying the method of two frequencies auxiliary currents overlapRobert VaynshteynVera ShestakovaSergey PashkovskiySvyatoslav YudinAleksey SerbulovThe urgency of the discussed issue is caused by the need to control automatic tuning of the arc-extinguishing reactor in a medium-voltage power system. Full effect of the application of such reactors takes place in the case if ARC-extinguishing reactor is automatically adjusted coils in resonance with the network total capacity. To realize automatic adjustment it is necessary to obtain continuously the information on deviation from resonance in the form of electrical signal. The main aim of the research is to design the method for controlling arc-extinguishing reactor adjustment in medium-voltage power systems, based on superposition of two different non-industrial frequencies currents. Typical high-voltage electrical equipment can be used for the design. Investigation methods: mathematical modeling with software packages MATHCAD, MATLAB. Results: It is shown that the method proposed is sensitive enough to small changes in detuning of the capacitive earth fault currents. The authors have determined that currents could be input into the network through the winding of a conventional voltage transformer connected by open delta. The absolute methodical error of the compensation detuning measurements was calculated. It is caused by conductance in a zero sequence circuit. It was proved that typically absolute methodical error does not exceed 0,002. The paper introduces the algorithms of processing electrical quantities with frequencies of superimposed currents when the electric signal characterizing compensation detuning does not depend on absolute values of network total capacitive current.http://izvestiya-tpu.ru/archive/article/view/1473ARC-extinguishing reactormeasuring the detuning compensationcurrents of two frequenciesvoltage transformermethodical error
spellingShingle Robert Vaynshteyn
Vera Shestakova
Sergey Pashkovskiy
Svyatoslav Yudin
Aleksey Serbulov
Automatic tuning of arc-extinguishing reactors for a medium-voltage power system 6-35 kV applying the method of two frequencies auxiliary currents overlap
Известия Томского политехнического университета: Инжиниринг георесурсов
ARC-extinguishing reactor
measuring the detuning compensation
currents of two frequencies
voltage transformer
methodical error
title Automatic tuning of arc-extinguishing reactors for a medium-voltage power system 6-35 kV applying the method of two frequencies auxiliary currents overlap
title_full Automatic tuning of arc-extinguishing reactors for a medium-voltage power system 6-35 kV applying the method of two frequencies auxiliary currents overlap
title_fullStr Automatic tuning of arc-extinguishing reactors for a medium-voltage power system 6-35 kV applying the method of two frequencies auxiliary currents overlap
title_full_unstemmed Automatic tuning of arc-extinguishing reactors for a medium-voltage power system 6-35 kV applying the method of two frequencies auxiliary currents overlap
title_short Automatic tuning of arc-extinguishing reactors for a medium-voltage power system 6-35 kV applying the method of two frequencies auxiliary currents overlap
title_sort automatic tuning of arc extinguishing reactors for a medium voltage power system 6 35 kv applying the method of two frequencies auxiliary currents overlap
topic ARC-extinguishing reactor
measuring the detuning compensation
currents of two frequencies
voltage transformer
methodical error
url http://izvestiya-tpu.ru/archive/article/view/1473
work_keys_str_mv AT robertvaynshteyn automatictuningofarcextinguishingreactorsforamediumvoltagepowersystem635kvapplyingthemethodoftwofrequenciesauxiliarycurrentsoverlap
AT verashestakova automatictuningofarcextinguishingreactorsforamediumvoltagepowersystem635kvapplyingthemethodoftwofrequenciesauxiliarycurrentsoverlap
AT sergeypashkovskiy automatictuningofarcextinguishingreactorsforamediumvoltagepowersystem635kvapplyingthemethodoftwofrequenciesauxiliarycurrentsoverlap
AT svyatoslavyudin automatictuningofarcextinguishingreactorsforamediumvoltagepowersystem635kvapplyingthemethodoftwofrequenciesauxiliarycurrentsoverlap
AT alekseyserbulov automatictuningofarcextinguishingreactorsforamediumvoltagepowersystem635kvapplyingthemethodoftwofrequenciesauxiliarycurrentsoverlap