Safety and cost-effectiveness analysis of using intermittent inflation and compression device during drug anticoagulation window period after artificial knee arthroplasty

Objective To analyze the safety and cost-effectiveness of intermittent pneumatic compression (IPC) during the intermittent pneumatic interval after total knee arthroplasty (TKA). Methods A total of 337 patients who underwent TKA surgery were included and randomly divided into experimental group (n=1...

Full description

Bibliographic Details
Main Authors: YANG Changfeng, ZHOU Yuanyuan, HUANG Ying, LAI Linyu, ZHANG Yumei
Format: Article
Language:zho
Published: Editorial Office of Journal of Army Medical University 2023-03-01
Series:陆军军医大学学报
Subjects:
Online Access:http://aammt.tmmu.edu.cn/html/202209271.htm
_version_ 1797869990668402688
author YANG Changfeng
YANG Changfeng
ZHOU Yuanyuan
HUANG Ying
LAI Linyu
ZHANG Yumei
author_facet YANG Changfeng
YANG Changfeng
ZHOU Yuanyuan
HUANG Ying
LAI Linyu
ZHANG Yumei
author_sort YANG Changfeng
collection DOAJ
description Objective To analyze the safety and cost-effectiveness of intermittent pneumatic compression (IPC) during the intermittent pneumatic interval after total knee arthroplasty (TKA). Methods A total of 337 patients who underwent TKA surgery were included and randomly divided into experimental group (n=168) and control group (n=169). The experimental group continued to use IPC for both lower limbs during the anticoagulant window period, while the control group continued to use IPC for both lower limbs immediately after surgery to the time of getting out of bed. Muscular calf vein thrombosis (MCVT) prevention rate, D2 polymer level, total postoperative blood loss, and cost-effectiveness ratio were compared between the 2 groups in 1 d after surgery. Results There were no statistical significances in MCVT prevention effective rate, hemoglobin level, total blood loss, and D2 polymer level between the 2 groups in 1 d after surgery. The IPC time was 6.00 (6.00, 6.00) h in the experimental group, significantly shorter than that in the control group [20.00 (15.00, 24.25) h, P < 0.01]. The total cost of IPC was significantly lower in the experimental group than the control group [172.84 (172.84, 172.84) vs 628.37 (461.82, 758.49) Yuan, P < 0.01]. The cost-effectiveness ratio of the experimental group (2.23) was lower than that of the control group (7.75). Conclusion The use of IPC during the anticoagulant window after TKA has good safety and better cost-effectiveness than the continuous use of IPC after surgery.
first_indexed 2024-04-10T00:20:18Z
format Article
id doaj.art-a2c81f3c094840968e07be3b95d92cdd
institution Directory Open Access Journal
issn 2097-0927
language zho
last_indexed 2024-04-10T00:20:18Z
publishDate 2023-03-01
publisher Editorial Office of Journal of Army Medical University
record_format Article
series 陆军军医大学学报
spelling doaj.art-a2c81f3c094840968e07be3b95d92cdd2023-03-16T03:05:36ZzhoEditorial Office of Journal of Army Medical University陆军军医大学学报2097-09272023-03-0145515045510.16016/j.2097-0927.202209271Safety and cost-effectiveness analysis of using intermittent inflation and compression device during drug anticoagulation window period after artificial knee arthroplastyYANG Changfeng0YANG Changfeng1ZHOU Yuanyuan2HUANG Ying3 LAI Linyu4 ZHANG Yumei5Department of Orthopedics, Second Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, 400037, ChinaDepartment of Orthopedics, Second Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, 400037, ChinaDepartment of Orthopedics, Second Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, 400037, ChinaDepartment of Ultrasonography, Second Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, 400037, ChinaDepartment of Orthopedics, Second Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, 400037, ChinaDepartment of Orthopedics, Second Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, 400037, ChinaObjective To analyze the safety and cost-effectiveness of intermittent pneumatic compression (IPC) during the intermittent pneumatic interval after total knee arthroplasty (TKA). Methods A total of 337 patients who underwent TKA surgery were included and randomly divided into experimental group (n=168) and control group (n=169). The experimental group continued to use IPC for both lower limbs during the anticoagulant window period, while the control group continued to use IPC for both lower limbs immediately after surgery to the time of getting out of bed. Muscular calf vein thrombosis (MCVT) prevention rate, D2 polymer level, total postoperative blood loss, and cost-effectiveness ratio were compared between the 2 groups in 1 d after surgery. Results There were no statistical significances in MCVT prevention effective rate, hemoglobin level, total blood loss, and D2 polymer level between the 2 groups in 1 d after surgery. The IPC time was 6.00 (6.00, 6.00) h in the experimental group, significantly shorter than that in the control group [20.00 (15.00, 24.25) h, P < 0.01]. The total cost of IPC was significantly lower in the experimental group than the control group [172.84 (172.84, 172.84) vs 628.37 (461.82, 758.49) Yuan, P < 0.01]. The cost-effectiveness ratio of the experimental group (2.23) was lower than that of the control group (7.75). Conclusion The use of IPC during the anticoagulant window after TKA has good safety and better cost-effectiveness than the continuous use of IPC after surgery. http://aammt.tmmu.edu.cn/html/202209271.htmtotal knee arthroplastyintermittent pneumatic compressiondrug anticoagulationdrug window periodcost-effectiveness
spellingShingle YANG Changfeng
YANG Changfeng
ZHOU Yuanyuan
HUANG Ying
LAI Linyu
ZHANG Yumei
Safety and cost-effectiveness analysis of using intermittent inflation and compression device during drug anticoagulation window period after artificial knee arthroplasty
陆军军医大学学报
total knee arthroplasty
intermittent pneumatic compression
drug anticoagulation
drug window period
cost-effectiveness
title Safety and cost-effectiveness analysis of using intermittent inflation and compression device during drug anticoagulation window period after artificial knee arthroplasty
title_full Safety and cost-effectiveness analysis of using intermittent inflation and compression device during drug anticoagulation window period after artificial knee arthroplasty
title_fullStr Safety and cost-effectiveness analysis of using intermittent inflation and compression device during drug anticoagulation window period after artificial knee arthroplasty
title_full_unstemmed Safety and cost-effectiveness analysis of using intermittent inflation and compression device during drug anticoagulation window period after artificial knee arthroplasty
title_short Safety and cost-effectiveness analysis of using intermittent inflation and compression device during drug anticoagulation window period after artificial knee arthroplasty
title_sort safety and cost effectiveness analysis of using intermittent inflation and compression device during drug anticoagulation window period after artificial knee arthroplasty
topic total knee arthroplasty
intermittent pneumatic compression
drug anticoagulation
drug window period
cost-effectiveness
url http://aammt.tmmu.edu.cn/html/202209271.htm
work_keys_str_mv AT yangchangfeng safetyandcosteffectivenessanalysisofusingintermittentinflationandcompressiondeviceduringdruganticoagulationwindowperiodafterartificialkneearthroplasty
AT yangchangfeng safetyandcosteffectivenessanalysisofusingintermittentinflationandcompressiondeviceduringdruganticoagulationwindowperiodafterartificialkneearthroplasty
AT zhouyuanyuan safetyandcosteffectivenessanalysisofusingintermittentinflationandcompressiondeviceduringdruganticoagulationwindowperiodafterartificialkneearthroplasty
AT huangying safetyandcosteffectivenessanalysisofusingintermittentinflationandcompressiondeviceduringdruganticoagulationwindowperiodafterartificialkneearthroplasty
AT lailinyu safetyandcosteffectivenessanalysisofusingintermittentinflationandcompressiondeviceduringdruganticoagulationwindowperiodafterartificialkneearthroplasty
AT zhangyumei safetyandcosteffectivenessanalysisofusingintermittentinflationandcompressiondeviceduringdruganticoagulationwindowperiodafterartificialkneearthroplasty