Retinal Oximetry with Scanning Laser Ophthalmoscope in Infants.

Dual wavelength retinal oximetry has been developed for adults, but is not available for infants. Retinal oximetry may provide insight into the pathophysiology of oxygen-mediated diseases like retinopathy of prematurity. More insight in the oxygen metabolism of the retina in infants may provide valu...

Full description

Bibliographic Details
Main Authors: Wouter B Vehmeijer, Vigdis Magnusdottir, Thorunn S Eliasdottir, Sveinn Hakon Hardarson, Nicoline E Schalij-Delfos, Einar Stefánsson
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2016-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4740427?pdf=render
_version_ 1819103556693655552
author Wouter B Vehmeijer
Vigdis Magnusdottir
Thorunn S Eliasdottir
Sveinn Hakon Hardarson
Nicoline E Schalij-Delfos
Einar Stefánsson
author_facet Wouter B Vehmeijer
Vigdis Magnusdottir
Thorunn S Eliasdottir
Sveinn Hakon Hardarson
Nicoline E Schalij-Delfos
Einar Stefánsson
author_sort Wouter B Vehmeijer
collection DOAJ
description Dual wavelength retinal oximetry has been developed for adults, but is not available for infants. Retinal oximetry may provide insight into the pathophysiology of oxygen-mediated diseases like retinopathy of prematurity. More insight in the oxygen metabolism of the retina in infants may provide valuable clues for better understanding and subsequent prevention or treatment of the disease. The measurements of oxygen saturation are obtained with two fundus images simultaneously captured in two different wavelengths of light. The comparison in light absorption of oxygenated and deoxygenated hemoglobin can be used to estimate the oxygen saturation within the retinal vessels by means of a software algorithm. This study aims to make retinal oximetry available for neonates. The first step towards estimating retinal oxygen saturation is determining the optical density ratio. Therefore, the purpose of this study is to image healthy newborn infants with a scanning laser ophthalmoscope and determine the optical density ratio for retinal oximetry analysis.Images of the retina of full-term healthy infants were obtained with an SLO, Optomap 200Tx (Optos), with two laser wavelengths (532nm and 633nm). The infant lay face down on the lower arm of the parent, while the parent supported the chest and chin with one hand, and stabilized the back with the other hand. No mydriatics or eyelid specula were used during this study. The images were analyzed with modified Oxymap Analyzer software for calculation of the Optical Density Ratio (ODR) and vessel width. The ODR is inversely and approximately linearly related to the oxygen saturation. Measurements were included from the superotemporal vessel pair. A paired t-test was used for statistical analysis.Fifty-nine infants, (58% female), were included with mean gestational age of 40 ± 1.3 weeks (mean ± SD) and mean post-natal age of 16 ± 4.8 days. A total of 28 images were selected for retinal oximetry analysis. The ODR was 0.256 ± 0.041 for the arterioles and 0.421 ± 0.089 for the venules (n = 28, p < 0.001). The measured vessel-width for the arterioles was 14.1 ± 2.7 pixels and for the venules 19.7 ± 3.7 pixels (n = 28, p < 0.001).Retinal oximetry can be performed in newborn infants by combining an SLO and a dual-wavelength algorithm software. Sensitivity of the approach is indicated by the fact that the ODR measurements are significantly different between the arterioles and the venules. However, more variability in ODR is seen with the SLO approach in babies than is seen with conventional oximetry in adults. This approach is completely non-invasive, non-contact and even avoids the use of mydriatics or eyelid specula.
first_indexed 2024-12-22T01:52:20Z
format Article
id doaj.art-a3051775391c4b5697d96a4495fce19d
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-22T01:52:20Z
publishDate 2016-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-a3051775391c4b5697d96a4495fce19d2022-12-21T18:42:52ZengPublic Library of Science (PLoS)PLoS ONE1932-62032016-01-01112e014807710.1371/journal.pone.0148077Retinal Oximetry with Scanning Laser Ophthalmoscope in Infants.Wouter B VehmeijerVigdis MagnusdottirThorunn S EliasdottirSveinn Hakon HardarsonNicoline E Schalij-DelfosEinar StefánssonDual wavelength retinal oximetry has been developed for adults, but is not available for infants. Retinal oximetry may provide insight into the pathophysiology of oxygen-mediated diseases like retinopathy of prematurity. More insight in the oxygen metabolism of the retina in infants may provide valuable clues for better understanding and subsequent prevention or treatment of the disease. The measurements of oxygen saturation are obtained with two fundus images simultaneously captured in two different wavelengths of light. The comparison in light absorption of oxygenated and deoxygenated hemoglobin can be used to estimate the oxygen saturation within the retinal vessels by means of a software algorithm. This study aims to make retinal oximetry available for neonates. The first step towards estimating retinal oxygen saturation is determining the optical density ratio. Therefore, the purpose of this study is to image healthy newborn infants with a scanning laser ophthalmoscope and determine the optical density ratio for retinal oximetry analysis.Images of the retina of full-term healthy infants were obtained with an SLO, Optomap 200Tx (Optos), with two laser wavelengths (532nm and 633nm). The infant lay face down on the lower arm of the parent, while the parent supported the chest and chin with one hand, and stabilized the back with the other hand. No mydriatics or eyelid specula were used during this study. The images were analyzed with modified Oxymap Analyzer software for calculation of the Optical Density Ratio (ODR) and vessel width. The ODR is inversely and approximately linearly related to the oxygen saturation. Measurements were included from the superotemporal vessel pair. A paired t-test was used for statistical analysis.Fifty-nine infants, (58% female), were included with mean gestational age of 40 ± 1.3 weeks (mean ± SD) and mean post-natal age of 16 ± 4.8 days. A total of 28 images were selected for retinal oximetry analysis. The ODR was 0.256 ± 0.041 for the arterioles and 0.421 ± 0.089 for the venules (n = 28, p < 0.001). The measured vessel-width for the arterioles was 14.1 ± 2.7 pixels and for the venules 19.7 ± 3.7 pixels (n = 28, p < 0.001).Retinal oximetry can be performed in newborn infants by combining an SLO and a dual-wavelength algorithm software. Sensitivity of the approach is indicated by the fact that the ODR measurements are significantly different between the arterioles and the venules. However, more variability in ODR is seen with the SLO approach in babies than is seen with conventional oximetry in adults. This approach is completely non-invasive, non-contact and even avoids the use of mydriatics or eyelid specula.http://europepmc.org/articles/PMC4740427?pdf=render
spellingShingle Wouter B Vehmeijer
Vigdis Magnusdottir
Thorunn S Eliasdottir
Sveinn Hakon Hardarson
Nicoline E Schalij-Delfos
Einar Stefánsson
Retinal Oximetry with Scanning Laser Ophthalmoscope in Infants.
PLoS ONE
title Retinal Oximetry with Scanning Laser Ophthalmoscope in Infants.
title_full Retinal Oximetry with Scanning Laser Ophthalmoscope in Infants.
title_fullStr Retinal Oximetry with Scanning Laser Ophthalmoscope in Infants.
title_full_unstemmed Retinal Oximetry with Scanning Laser Ophthalmoscope in Infants.
title_short Retinal Oximetry with Scanning Laser Ophthalmoscope in Infants.
title_sort retinal oximetry with scanning laser ophthalmoscope in infants
url http://europepmc.org/articles/PMC4740427?pdf=render
work_keys_str_mv AT wouterbvehmeijer retinaloximetrywithscanninglaserophthalmoscopeininfants
AT vigdismagnusdottir retinaloximetrywithscanninglaserophthalmoscopeininfants
AT thorunnseliasdottir retinaloximetrywithscanninglaserophthalmoscopeininfants
AT sveinnhakonhardarson retinaloximetrywithscanninglaserophthalmoscopeininfants
AT nicolineeschalijdelfos retinaloximetrywithscanninglaserophthalmoscopeininfants
AT einarstefansson retinaloximetrywithscanninglaserophthalmoscopeininfants