Precisión de la tomografía de 64 cortes en el diagnóstico de estenosis coronaria significativa Accuracy of 64-slice computed tomography in the diagnosis of significant coronary stenosis
La coronariografía invasiva (CI) constituye el patrón de referencia para el estudio de las arterias coronarias. Se ha planteado que la tomografía computarizada de múltiples cortes (TCMC) puede evitar la CI. Se estudiaron 62 pacientes, 50 del sexo masculino, edad media 56 ± 8 años para evaluar la pre...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | Spanish |
Published: |
Editorial Ciencias Médicas
2007-12-01
|
Series: | Revista Cubana de Medicina |
Subjects: | |
Online Access: | http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0034-75232007000400001 |
_version_ | 1818460999565443072 |
---|---|
author | Vladimir Mendoza Rodríguez Luis Roberto Llerena Rojas Lorenzo Llerena Rojas Leonardo López Ferrero Verónica Milián Sierra Romualdo Linares Machado Lidia Rodríguez Nande |
author_facet | Vladimir Mendoza Rodríguez Luis Roberto Llerena Rojas Lorenzo Llerena Rojas Leonardo López Ferrero Verónica Milián Sierra Romualdo Linares Machado Lidia Rodríguez Nande |
author_sort | Vladimir Mendoza Rodríguez |
collection | DOAJ |
description | La coronariografía invasiva (CI) constituye el patrón de referencia para el estudio de las arterias coronarias. Se ha planteado que la tomografía computarizada de múltiples cortes (TCMC) puede evitar la CI. Se estudiaron 62 pacientes, 50 del sexo masculino, edad media 56 ± 8 años para evaluar la precisión diagnóstica de la TCMC de 64 cortes en la detección de estenosis coronarias significativas (ECS), comparándola con la CI. Se les realizó la CI por presentar ECS o persistencia de los síntomas. Se determinó sensibilidad (S), especificidad (E), valor predictivo positivo (VPP), valor predictivo negativo (VPN) y precisión predictiva (PP) por pacientes y por arterias. La S, la E, el VPP, el VPN y la PP fueron 96,4; 91,2; 87; 96,8 y 93,5 %, respectivamente, por pacientes, y 95,7; 97; 88,2; 98,9 y 96,7 %, respectivamente, por arterias. Se concluyó que la TCMC puede sustituir la CI en pacientes seleccionados.<br>Invasive coronariography (IC) is the reference pattern for the study of coronary arteries. It has been stated that multiple slice computed tomography (MSCT) may avoid IC. 62 patients, 50 of whom were males, with mean age 56 ± 8, were studied to evaluate the diagnostic accuracy of the 64-slice MSCT in the detection of significant coronary stenoses (SCS), comparing it with IC. IC was performed due to the presence of SCS or persistence of the symptoms. Sensitivity (S), specificity (E), positive predictive value (PPV), negative predictive value (NPV) and predictive accuracy (PA) were determined by patients and arteries. S, E, PPV, NPV and PA were 96.4; 91.2; 87; 96.8 and 93.5 % per patient, respectively; whereas they were 95.7; 97; 88.2; 98.9 and 96.7 % by artery, respectively. It was concluded that MSCT may replace IC in selected patients. |
first_indexed | 2024-12-14T23:39:10Z |
format | Article |
id | doaj.art-a3e7be45802b4c6384a802c4b35625c9 |
institution | Directory Open Access Journal |
issn | 0034-7523 1561-302X |
language | Spanish |
last_indexed | 2024-12-14T23:39:10Z |
publishDate | 2007-12-01 |
publisher | Editorial Ciencias Médicas |
record_format | Article |
series | Revista Cubana de Medicina |
spelling | doaj.art-a3e7be45802b4c6384a802c4b35625c92022-12-21T22:43:33ZspaEditorial Ciencias MédicasRevista Cubana de Medicina0034-75231561-302X2007-12-014640Precisión de la tomografía de 64 cortes en el diagnóstico de estenosis coronaria significativa Accuracy of 64-slice computed tomography in the diagnosis of significant coronary stenosisVladimir Mendoza RodríguezLuis Roberto Llerena RojasLorenzo Llerena RojasLeonardo López FerreroVerónica Milián SierraRomualdo Linares MachadoLidia Rodríguez NandeLa coronariografía invasiva (CI) constituye el patrón de referencia para el estudio de las arterias coronarias. Se ha planteado que la tomografía computarizada de múltiples cortes (TCMC) puede evitar la CI. Se estudiaron 62 pacientes, 50 del sexo masculino, edad media 56 ± 8 años para evaluar la precisión diagnóstica de la TCMC de 64 cortes en la detección de estenosis coronarias significativas (ECS), comparándola con la CI. Se les realizó la CI por presentar ECS o persistencia de los síntomas. Se determinó sensibilidad (S), especificidad (E), valor predictivo positivo (VPP), valor predictivo negativo (VPN) y precisión predictiva (PP) por pacientes y por arterias. La S, la E, el VPP, el VPN y la PP fueron 96,4; 91,2; 87; 96,8 y 93,5 %, respectivamente, por pacientes, y 95,7; 97; 88,2; 98,9 y 96,7 %, respectivamente, por arterias. Se concluyó que la TCMC puede sustituir la CI en pacientes seleccionados.<br>Invasive coronariography (IC) is the reference pattern for the study of coronary arteries. It has been stated that multiple slice computed tomography (MSCT) may avoid IC. 62 patients, 50 of whom were males, with mean age 56 ± 8, were studied to evaluate the diagnostic accuracy of the 64-slice MSCT in the detection of significant coronary stenoses (SCS), comparing it with IC. IC was performed due to the presence of SCS or persistence of the symptoms. Sensitivity (S), specificity (E), positive predictive value (PPV), negative predictive value (NPV) and predictive accuracy (PA) were determined by patients and arteries. S, E, PPV, NPV and PA were 96.4; 91.2; 87; 96.8 and 93.5 % per patient, respectively; whereas they were 95.7; 97; 88.2; 98.9 and 96.7 % by artery, respectively. It was concluded that MSCT may replace IC in selected patients.http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0034-75232007000400001Tomografía computarizada multicortesprecisión diagnósticacoronariografía invasivaestenosis coronaria significativaMultiple slice computed tomographydiagnostic accuracyinvasive coronariographysignificant coronary stenosis |
spellingShingle | Vladimir Mendoza Rodríguez Luis Roberto Llerena Rojas Lorenzo Llerena Rojas Leonardo López Ferrero Verónica Milián Sierra Romualdo Linares Machado Lidia Rodríguez Nande Precisión de la tomografía de 64 cortes en el diagnóstico de estenosis coronaria significativa Accuracy of 64-slice computed tomography in the diagnosis of significant coronary stenosis Revista Cubana de Medicina Tomografía computarizada multicortes precisión diagnóstica coronariografía invasiva estenosis coronaria significativa Multiple slice computed tomography diagnostic accuracy invasive coronariography significant coronary stenosis |
title | Precisión de la tomografía de 64 cortes en el diagnóstico de estenosis coronaria significativa Accuracy of 64-slice computed tomography in the diagnosis of significant coronary stenosis |
title_full | Precisión de la tomografía de 64 cortes en el diagnóstico de estenosis coronaria significativa Accuracy of 64-slice computed tomography in the diagnosis of significant coronary stenosis |
title_fullStr | Precisión de la tomografía de 64 cortes en el diagnóstico de estenosis coronaria significativa Accuracy of 64-slice computed tomography in the diagnosis of significant coronary stenosis |
title_full_unstemmed | Precisión de la tomografía de 64 cortes en el diagnóstico de estenosis coronaria significativa Accuracy of 64-slice computed tomography in the diagnosis of significant coronary stenosis |
title_short | Precisión de la tomografía de 64 cortes en el diagnóstico de estenosis coronaria significativa Accuracy of 64-slice computed tomography in the diagnosis of significant coronary stenosis |
title_sort | precision de la tomografia de 64 cortes en el diagnostico de estenosis coronaria significativa accuracy of 64 slice computed tomography in the diagnosis of significant coronary stenosis |
topic | Tomografía computarizada multicortes precisión diagnóstica coronariografía invasiva estenosis coronaria significativa Multiple slice computed tomography diagnostic accuracy invasive coronariography significant coronary stenosis |
url | http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0034-75232007000400001 |
work_keys_str_mv | AT vladimirmendozarodriguez precisiondelatomografiade64corteseneldiagnosticodeestenosiscoronariasignificativaaccuracyof64slicecomputedtomographyinthediagnosisofsignificantcoronarystenosis AT luisrobertollerenarojas precisiondelatomografiade64corteseneldiagnosticodeestenosiscoronariasignificativaaccuracyof64slicecomputedtomographyinthediagnosisofsignificantcoronarystenosis AT lorenzollerenarojas precisiondelatomografiade64corteseneldiagnosticodeestenosiscoronariasignificativaaccuracyof64slicecomputedtomographyinthediagnosisofsignificantcoronarystenosis AT leonardolopezferrero precisiondelatomografiade64corteseneldiagnosticodeestenosiscoronariasignificativaaccuracyof64slicecomputedtomographyinthediagnosisofsignificantcoronarystenosis AT veronicamiliansierra precisiondelatomografiade64corteseneldiagnosticodeestenosiscoronariasignificativaaccuracyof64slicecomputedtomographyinthediagnosisofsignificantcoronarystenosis AT romualdolinaresmachado precisiondelatomografiade64corteseneldiagnosticodeestenosiscoronariasignificativaaccuracyof64slicecomputedtomographyinthediagnosisofsignificantcoronarystenosis AT lidiarodrigueznande precisiondelatomografiade64corteseneldiagnosticodeestenosiscoronariasignificativaaccuracyof64slicecomputedtomographyinthediagnosisofsignificantcoronarystenosis |