Remote Monitoring of Visual Function in Patients with Maculopathy: The Aphelion Study

Abstract Introduction Remote monitoring of vision, using tools such as the shape discrimination hyperacuity (SDH) test, can detect disease activity in patients with maculopathy. We determined the in-clinic accuracy and repeatability of three myVisionTrack expanded version (mVTx) tests for self-testi...

Full description

Bibliographic Details
Main Authors: Anthony Joseph, Mark Bullimore, Faye Drawnel, Marco Miranda, Zoe Morgan, Yi-Zhong Wang
Format: Article
Language:English
Published: Adis, Springer Healthcare 2023-11-01
Series:Ophthalmology and Therapy
Subjects:
Online Access:https://doi.org/10.1007/s40123-023-00854-2
_version_ 1827382357717417984
author Anthony Joseph
Mark Bullimore
Faye Drawnel
Marco Miranda
Zoe Morgan
Yi-Zhong Wang
author_facet Anthony Joseph
Mark Bullimore
Faye Drawnel
Marco Miranda
Zoe Morgan
Yi-Zhong Wang
author_sort Anthony Joseph
collection DOAJ
description Abstract Introduction Remote monitoring of vision, using tools such as the shape discrimination hyperacuity (SDH) test, can detect disease activity in patients with maculopathy. We determined the in-clinic accuracy and repeatability of three myVisionTrack expanded version (mVTx) tests for self-testing of visual acuity (VA) and contrast sensitivity. Methods Aphelion, a single-arm, prospective study conducted at two sites in the USA, included adults with any maculopathy and a baseline VA of 0.7 log of minimum angle of resolution (logMAR) (Snellen 20/100) or better. Participants completed the mVTx tests (tumbling E, Landolt C, contrast sensitivity, and SDH) and standard clinical tests (near and distance Early Treatment Diabetic Retinopathy Study [ETDRS] charts and the Pelli–Robson contrast sensitivity chart). Test–retest repeatability and agreement between the mVTx tests and the corresponding clinical test were assessed by Bland–Altman analyses. Participants also completed a usability survey. Results The mean age of the 122 participants was 67 years. The most common diagnosis was age-related macular degeneration (42% of patients). The tumbling E test had a test–retest 95% limit of agreement (LoA) of ± 0.18 logMAR; the Landolt C test, ± 0.23 logMAR; the SDH test, ± 0.24 logMAR; and the contrast sensitivity test, ± 0.32 log contrast threshold (logCT). Compared with the distance ETDRS chart, the LoA was ± 0.35 logMAR for the tumbling E test (mean difference, − 0.07 logMAR) and ± 0.39 logMAR for the Landolt C test (mean difference, 0.03 logMAR). For the contrast sensitivity test, the LoA compared with the Pelli–Robson chart was ± 0.30 logCT (mean difference, − 0.25 logCT). Most participants (85%) reported that they learned the tests quickly. The tumbling E test scored the highest on ease of use. Conclusion The mVTx tests of VA are accurate and repeatable, supporting their potential use alongside the SDH test to detect disease progression remotely between clinic visits.
first_indexed 2024-03-08T14:19:24Z
format Article
id doaj.art-a410eb91d17a46ccab9ae0bb3cd54cb5
institution Directory Open Access Journal
issn 2193-8245
2193-6528
language English
last_indexed 2024-03-08T14:19:24Z
publishDate 2023-11-01
publisher Adis, Springer Healthcare
record_format Article
series Ophthalmology and Therapy
spelling doaj.art-a410eb91d17a46ccab9ae0bb3cd54cb52024-01-14T12:14:25ZengAdis, Springer HealthcareOphthalmology and Therapy2193-82452193-65282023-11-0113140942210.1007/s40123-023-00854-2Remote Monitoring of Visual Function in Patients with Maculopathy: The Aphelion StudyAnthony Joseph0Mark Bullimore1Faye Drawnel2Marco Miranda3Zoe Morgan4Yi-Zhong Wang5Retina AssociatesUniversity of Houston College of OptometryF. Hoffmann-La Roche AGRoche Products, Ltd.F. Hoffmann-La Roche AGRetina Foundation of the SouthwestAbstract Introduction Remote monitoring of vision, using tools such as the shape discrimination hyperacuity (SDH) test, can detect disease activity in patients with maculopathy. We determined the in-clinic accuracy and repeatability of three myVisionTrack expanded version (mVTx) tests for self-testing of visual acuity (VA) and contrast sensitivity. Methods Aphelion, a single-arm, prospective study conducted at two sites in the USA, included adults with any maculopathy and a baseline VA of 0.7 log of minimum angle of resolution (logMAR) (Snellen 20/100) or better. Participants completed the mVTx tests (tumbling E, Landolt C, contrast sensitivity, and SDH) and standard clinical tests (near and distance Early Treatment Diabetic Retinopathy Study [ETDRS] charts and the Pelli–Robson contrast sensitivity chart). Test–retest repeatability and agreement between the mVTx tests and the corresponding clinical test were assessed by Bland–Altman analyses. Participants also completed a usability survey. Results The mean age of the 122 participants was 67 years. The most common diagnosis was age-related macular degeneration (42% of patients). The tumbling E test had a test–retest 95% limit of agreement (LoA) of ± 0.18 logMAR; the Landolt C test, ± 0.23 logMAR; the SDH test, ± 0.24 logMAR; and the contrast sensitivity test, ± 0.32 log contrast threshold (logCT). Compared with the distance ETDRS chart, the LoA was ± 0.35 logMAR for the tumbling E test (mean difference, − 0.07 logMAR) and ± 0.39 logMAR for the Landolt C test (mean difference, 0.03 logMAR). For the contrast sensitivity test, the LoA compared with the Pelli–Robson chart was ± 0.30 logCT (mean difference, − 0.25 logCT). Most participants (85%) reported that they learned the tests quickly. The tumbling E test scored the highest on ease of use. Conclusion The mVTx tests of VA are accurate and repeatable, supporting their potential use alongside the SDH test to detect disease progression remotely between clinic visits.https://doi.org/10.1007/s40123-023-00854-2Contrast sensitivityHyperacuityMaculopathyRemote monitoringVisual acuitySmartphone application
spellingShingle Anthony Joseph
Mark Bullimore
Faye Drawnel
Marco Miranda
Zoe Morgan
Yi-Zhong Wang
Remote Monitoring of Visual Function in Patients with Maculopathy: The Aphelion Study
Ophthalmology and Therapy
Contrast sensitivity
Hyperacuity
Maculopathy
Remote monitoring
Visual acuity
Smartphone application
title Remote Monitoring of Visual Function in Patients with Maculopathy: The Aphelion Study
title_full Remote Monitoring of Visual Function in Patients with Maculopathy: The Aphelion Study
title_fullStr Remote Monitoring of Visual Function in Patients with Maculopathy: The Aphelion Study
title_full_unstemmed Remote Monitoring of Visual Function in Patients with Maculopathy: The Aphelion Study
title_short Remote Monitoring of Visual Function in Patients with Maculopathy: The Aphelion Study
title_sort remote monitoring of visual function in patients with maculopathy the aphelion study
topic Contrast sensitivity
Hyperacuity
Maculopathy
Remote monitoring
Visual acuity
Smartphone application
url https://doi.org/10.1007/s40123-023-00854-2
work_keys_str_mv AT anthonyjoseph remotemonitoringofvisualfunctioninpatientswithmaculopathytheaphelionstudy
AT markbullimore remotemonitoringofvisualfunctioninpatientswithmaculopathytheaphelionstudy
AT fayedrawnel remotemonitoringofvisualfunctioninpatientswithmaculopathytheaphelionstudy
AT marcomiranda remotemonitoringofvisualfunctioninpatientswithmaculopathytheaphelionstudy
AT zoemorgan remotemonitoringofvisualfunctioninpatientswithmaculopathytheaphelionstudy
AT yizhongwang remotemonitoringofvisualfunctioninpatientswithmaculopathytheaphelionstudy