FAULT LOCATION ON A DISTRIBUTION FEEDER USING FAULT GENERATED HIGH FREQUENCY CURRENT SIGNATURES

This paper describes how the fault generated travelling waves detected in the current signals at a single location on a distribution feeder can be used for fault location. The method identifies the fault section and the probable location of the fault by comparing the relative distance of each “peak”...

Full description

Bibliographic Details
Main Authors: Hashim Hizam, P.A. Crossley
Format: Article
Language:English
Published: Universiti Brunei Darussalam 2017-11-01
Series:ASEAN Journal on Science and Technology for Development
Subjects:
Online Access:http://www.ajstd.org/index.php/ajstd/article/view/242
_version_ 1797331572759724032
author Hashim Hizam
P.A. Crossley
author_facet Hashim Hizam
P.A. Crossley
author_sort Hashim Hizam
collection DOAJ
description This paper describes how the fault generated travelling waves detected in the current signals at a single location on a distribution feeder can be used for fault location. The method identifies the fault section and the probable location of the fault by comparing the relative distance of each “peak” in the high frequency current signals to the known reflection points in the distribution feeder. The probable fault location is then used within a transient power system simulator that models the actual network. The resulting simulated current waveforms are then cross-correlated against the original signal. If the estimated fault location is correct, the high frequency signatures in the simulated waveform will be similar to those of the measured waveforms and the cross-correlation value will be a high positive value. If the signatures differ, the cross correlation value  will be negative or small. The simulation and correlation process is repeated with the next “most likely” fault location until a high degree of correlation is obtained. Simulation studies using PSCAD/EMTDC and analysis using cross-correlation suggest that this method can accurately locate a fault on a distribution feeder using measurements at a single location.
first_indexed 2024-03-08T07:37:22Z
format Article
id doaj.art-a4dff5fa0672402d95903ac6d05d1115
institution Directory Open Access Journal
issn 0217-5460
2224-9028
language English
last_indexed 2024-03-08T07:37:22Z
publishDate 2017-11-01
publisher Universiti Brunei Darussalam
record_format Article
series ASEAN Journal on Science and Technology for Development
spelling doaj.art-a4dff5fa0672402d95903ac6d05d11152024-02-02T18:44:45ZengUniversiti Brunei DarussalamASEAN Journal on Science and Technology for Development0217-54602224-90282017-11-0125219120310.29037/ajstd.242237FAULT LOCATION ON A DISTRIBUTION FEEDER USING FAULT GENERATED HIGH FREQUENCY CURRENT SIGNATURESHashim Hizam0P.A. Crossley1Department of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400, UPM Serdang, SelangorSchool of Electrical and Electronic Engineering, Queen’s University Belfast, Ashby Building, Stranmillis Road, Belfast BT9 5AH, Northern IslandThis paper describes how the fault generated travelling waves detected in the current signals at a single location on a distribution feeder can be used for fault location. The method identifies the fault section and the probable location of the fault by comparing the relative distance of each “peak” in the high frequency current signals to the known reflection points in the distribution feeder. The probable fault location is then used within a transient power system simulator that models the actual network. The resulting simulated current waveforms are then cross-correlated against the original signal. If the estimated fault location is correct, the high frequency signatures in the simulated waveform will be similar to those of the measured waveforms and the cross-correlation value will be a high positive value. If the signatures differ, the cross correlation value  will be negative or small. The simulation and correlation process is repeated with the next “most likely” fault location until a high degree of correlation is obtained. Simulation studies using PSCAD/EMTDC and analysis using cross-correlation suggest that this method can accurately locate a fault on a distribution feeder using measurements at a single location.http://www.ajstd.org/index.php/ajstd/article/view/242fault locationtravelling wavescross-correlationdistribution
spellingShingle Hashim Hizam
P.A. Crossley
FAULT LOCATION ON A DISTRIBUTION FEEDER USING FAULT GENERATED HIGH FREQUENCY CURRENT SIGNATURES
ASEAN Journal on Science and Technology for Development
fault location
travelling waves
cross-correlation
distribution
title FAULT LOCATION ON A DISTRIBUTION FEEDER USING FAULT GENERATED HIGH FREQUENCY CURRENT SIGNATURES
title_full FAULT LOCATION ON A DISTRIBUTION FEEDER USING FAULT GENERATED HIGH FREQUENCY CURRENT SIGNATURES
title_fullStr FAULT LOCATION ON A DISTRIBUTION FEEDER USING FAULT GENERATED HIGH FREQUENCY CURRENT SIGNATURES
title_full_unstemmed FAULT LOCATION ON A DISTRIBUTION FEEDER USING FAULT GENERATED HIGH FREQUENCY CURRENT SIGNATURES
title_short FAULT LOCATION ON A DISTRIBUTION FEEDER USING FAULT GENERATED HIGH FREQUENCY CURRENT SIGNATURES
title_sort fault location on a distribution feeder using fault generated high frequency current signatures
topic fault location
travelling waves
cross-correlation
distribution
url http://www.ajstd.org/index.php/ajstd/article/view/242
work_keys_str_mv AT hashimhizam faultlocationonadistributionfeederusingfaultgeneratedhighfrequencycurrentsignatures
AT pacrossley faultlocationonadistributionfeederusingfaultgeneratedhighfrequencycurrentsignatures