Automatic and manual image fusion of <sup>111</sup> In-pentetreotide SPECT and diagnostic CT in neuroendocrine tumor imaging - An evaluation

In the clinical diagnosis of neuroendocrine tumors (NET), the results of examinations, such as high-resolution computed tomography (CT) and single photon computerized tomography (SPECT), have conventionally been interpreted separately. The aim of the present study was to evaluate Hermes Multimodalit...

Full description

Bibliographic Details
Main Authors: Hedlund Elisabeth, Karlsson Jan-Erik, Starck Sven-&#x00C5;ke
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2010-01-01
Series:Journal of Medical Physics
Subjects:
Online Access:http://www.jmp.org.in/article.asp?issn=0971-6203;year=2010;volume=35;issue=4;spage=223;epage=228;aulast=Hedlund
_version_ 1811335571992215552
author Hedlund Elisabeth
Karlsson Jan-Erik
Starck Sven-&#x00C5;ke
author_facet Hedlund Elisabeth
Karlsson Jan-Erik
Starck Sven-&#x00C5;ke
author_sort Hedlund Elisabeth
collection DOAJ
description In the clinical diagnosis of neuroendocrine tumors (NET), the results of examinations, such as high-resolution computed tomography (CT) and single photon computerized tomography (SPECT), have conventionally been interpreted separately. The aim of the present study was to evaluate Hermes Multimodality&#8482; 5.0 H Image Fusion software-based automatic and manual image fusion of SPECT and CT for the localization of NET lesions. Out of 34 NET patients who were examined by means of somatostatin receptor scintigraphy (SRS) with 111In- pentetreotide along with SPECT, 22 patients had a CT examination of the abdomen, which was used in the fusion analysis. SPECT and CT data were fused using software with a registration algorithm based on normalized mutual information. The criteria for acceptable fusion were established at a maximum cranial or caudal dislocation of 25 mm between the images and at a reasonable consensus (in order of less than 1 cm) between outline of the reference organs. The automatic fusion was acceptable in 13 of the 22 examinations, whereas 9 fusions were not. However all the 22 examinations were acceptable at the manual fusion. The result of automatic fusion was better when the slice thickness of 5 mm was applied at CT examination, when the number of slices was below 100 in CT data and when both examinations included uptakes of pathological lesions. Retrospective manual image fusion of SPECT and CT is a relatively inexpensive but reliable method to be used in NET imaging. Automatic image fusion with specified software of SPECT and CT acts better when the number of CT slices is reduced to the SPECT volume and when corresponding pathological lesions appear at both SPECT and CT examinations.
first_indexed 2024-04-13T17:26:12Z
format Article
id doaj.art-a513ba738dbf44eb84459c3b105c1b0c
institution Directory Open Access Journal
issn 0971-6203
1998-3913
language English
last_indexed 2024-04-13T17:26:12Z
publishDate 2010-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Journal of Medical Physics
spelling doaj.art-a513ba738dbf44eb84459c3b105c1b0c2022-12-22T02:37:47ZengWolters Kluwer Medknow PublicationsJournal of Medical Physics0971-62031998-39132010-01-01354223228Automatic and manual image fusion of <sup>111</sup> In-pentetreotide SPECT and diagnostic CT in neuroendocrine tumor imaging - An evaluationHedlund ElisabethKarlsson Jan-ErikStarck Sven-&#x00C5;keIn the clinical diagnosis of neuroendocrine tumors (NET), the results of examinations, such as high-resolution computed tomography (CT) and single photon computerized tomography (SPECT), have conventionally been interpreted separately. The aim of the present study was to evaluate Hermes Multimodality&#8482; 5.0 H Image Fusion software-based automatic and manual image fusion of SPECT and CT for the localization of NET lesions. Out of 34 NET patients who were examined by means of somatostatin receptor scintigraphy (SRS) with 111In- pentetreotide along with SPECT, 22 patients had a CT examination of the abdomen, which was used in the fusion analysis. SPECT and CT data were fused using software with a registration algorithm based on normalized mutual information. The criteria for acceptable fusion were established at a maximum cranial or caudal dislocation of 25 mm between the images and at a reasonable consensus (in order of less than 1 cm) between outline of the reference organs. The automatic fusion was acceptable in 13 of the 22 examinations, whereas 9 fusions were not. However all the 22 examinations were acceptable at the manual fusion. The result of automatic fusion was better when the slice thickness of 5 mm was applied at CT examination, when the number of slices was below 100 in CT data and when both examinations included uptakes of pathological lesions. Retrospective manual image fusion of SPECT and CT is a relatively inexpensive but reliable method to be used in NET imaging. Automatic image fusion with specified software of SPECT and CT acts better when the number of CT slices is reduced to the SPECT volume and when corresponding pathological lesions appear at both SPECT and CT examinations.http://www.jmp.org.in/article.asp?issn=0971-6203;year=2010;volume=35;issue=4;spage=223;epage=228;aulast=HedlundComputed tomographyimage fusionneuroendocrine tumorssingle photon emission computed tomographysomatostatin receptor scintigraphy
spellingShingle Hedlund Elisabeth
Karlsson Jan-Erik
Starck Sven-&#x00C5;ke
Automatic and manual image fusion of <sup>111</sup> In-pentetreotide SPECT and diagnostic CT in neuroendocrine tumor imaging - An evaluation
Journal of Medical Physics
Computed tomography
image fusion
neuroendocrine tumors
single photon emission computed tomography
somatostatin receptor scintigraphy
title Automatic and manual image fusion of <sup>111</sup> In-pentetreotide SPECT and diagnostic CT in neuroendocrine tumor imaging - An evaluation
title_full Automatic and manual image fusion of <sup>111</sup> In-pentetreotide SPECT and diagnostic CT in neuroendocrine tumor imaging - An evaluation
title_fullStr Automatic and manual image fusion of <sup>111</sup> In-pentetreotide SPECT and diagnostic CT in neuroendocrine tumor imaging - An evaluation
title_full_unstemmed Automatic and manual image fusion of <sup>111</sup> In-pentetreotide SPECT and diagnostic CT in neuroendocrine tumor imaging - An evaluation
title_short Automatic and manual image fusion of <sup>111</sup> In-pentetreotide SPECT and diagnostic CT in neuroendocrine tumor imaging - An evaluation
title_sort automatic and manual image fusion of sup 111 sup in pentetreotide spect and diagnostic ct in neuroendocrine tumor imaging an evaluation
topic Computed tomography
image fusion
neuroendocrine tumors
single photon emission computed tomography
somatostatin receptor scintigraphy
url http://www.jmp.org.in/article.asp?issn=0971-6203;year=2010;volume=35;issue=4;spage=223;epage=228;aulast=Hedlund
work_keys_str_mv AT hedlundelisabeth automaticandmanualimagefusionofsup111supinpentetreotidespectanddiagnosticctinneuroendocrinetumorimaginganevaluation
AT karlssonjanerik automaticandmanualimagefusionofsup111supinpentetreotidespectanddiagnosticctinneuroendocrinetumorimaginganevaluation
AT starcksvenx00c5ke automaticandmanualimagefusionofsup111supinpentetreotidespectanddiagnosticctinneuroendocrinetumorimaginganevaluation