Analysis of loads and structural capacity of steel silo with corrugated wall for pelleted material
This paper deals with problems connected with the design and operation of thin-walled steel silos for storing pelleted materials. A failure of a faultily designed silo is described and its causes are examined. The parameters of the stored material were determined. The exceptional (unforeseen) loads...
Main Authors: | Ryszard Antonowicz, Czesław Bywalski, Mieczysław Kaminski |
---|---|
Format: | Article |
Language: | English |
Published: |
Vilnius Gediminas Technical University
2014-06-01
|
Series: | Journal of Civil Engineering and Management |
Subjects: | |
Online Access: | http://journals.vgtu.lt/index.php/JCEM/article/view/3135 |
Similar Items
-
THE FLOW OF RAPE SEED IN A SILO EQUIPPED WITH A DISCHARGE DEVICE
by: MIECZYSŁAW KAMIŃSKI, et al.
Published: (2003-10-01) -
LOADS ON WALLS AND INSERTS IN MASS-FLOW SILOS
by: SONGXIONG DING, et al.
Published: (2003-10-01) -
Current design of rectangular steel silos: limitations and improvement
by: Mohamed H. Abdelbarr, et al.
Published: (2024-03-01) -
SILO FAILURES: WHY DO THEY HAPPEN?
by: JOHN W. CARSON, et al.
Published: (2003-10-01) -
Silos : theory and practice /
by: 252339 Reimbert, Marcel L., et al.
Published: (1976)