Transesophageal probe placement increases endotracheal tube cuff pressure but is not associated with postoperative extubation failure after congenital cardiac surgery
Context: The concomitant use of cuffed endotracheal tubes (ETT) and transesophageal echocardiography (TEE) probes increases ETT cuff pressures (CP), which may contribute to mucosal ischemia and perioperative complications such as failed extubation. Aims: To assess changes in ETT CP after TEE inserti...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2020-01-01
|
Series: | Annals of Cardiac Anaesthesia |
Subjects: | |
Online Access: | http://www.annals.in/article.asp?issn=0971-9784;year=2020;volume=23;issue=4;spage=447;epage=452;aulast=Pan |
_version_ | 1831805423048458240 |
---|---|
author | Stephanie J Pan Stephen Z Frabitore Angela R Ingram Khoa N Nguyen Phillip S Adams |
author_facet | Stephanie J Pan Stephen Z Frabitore Angela R Ingram Khoa N Nguyen Phillip S Adams |
author_sort | Stephanie J Pan |
collection | DOAJ |
description | Context: The concomitant use of cuffed endotracheal tubes (ETT) and transesophageal echocardiography (TEE) probes increases ETT cuff pressures (CP), which may contribute to mucosal ischemia and perioperative complications such as failed extubation. Aims: To assess changes in ETT CP after TEE insertion in patients of different age groups undergoing congenital heart surgery and examine the relationship between ETT CP and postoperative extubation failure. Settings and Design: Single-center quality improvement project. Subjects and Methods: ETT CP was measured with a manometer following intubation and again after TEE insertion. Tracheal perfusion pressure was then calculated and postoperative extubation failures were recorded. Statistical Analysis: Chi-square testing, Fisher's-exact testing, one-way analysis of variance testing or Kruskal–Wallis testing with Dunn's pairwise, and student's t-test or Wilcoxon rank-sum testing were used to analyze the data. Results: Median ETT CP increased significantly after TEE insertion in each age group, with infants showing a smaller magnitude of increase (+2 [1-6] cm H2O, P < 0.001) than adults (+12 [8-14] cm H2O, P = 0.008) (intergroup comparison P = 0.002). Five patients (9%) failed extubation, all of which were infants. Within the infant subgroup, no significant difference existed between failed vs successful extubation regarding ETT CP during bypass (15 ± 1 vs 16 ± 2 mmHg, P = 0.206) or tracheal perfusion pressure pre-bypass (34 ± 9 vs 38 ± 11 mmHg, P = 0.518), during bypass (20 ± 9 vs 22 ± 6 mmHg, P = 0.697), or post-bypass (42 ± 9 vs 41 ± 9 mmHg, P = 0.923). There was a significant difference in cardiopulmonary bypass duration (151 ± 29 vs 85 ± 32 min, P < 0.001). Conclusion: Factors beyond intraoperative ETT CP likely play a larger role in postoperative extubation failure. |
first_indexed | 2024-12-22T19:23:46Z |
format | Article |
id | doaj.art-a5c15fd4baaa4e0998dbf30ceecd8f8e |
institution | Directory Open Access Journal |
issn | 0971-9784 |
language | English |
last_indexed | 2024-12-22T19:23:46Z |
publishDate | 2020-01-01 |
publisher | Wolters Kluwer Medknow Publications |
record_format | Article |
series | Annals of Cardiac Anaesthesia |
spelling | doaj.art-a5c15fd4baaa4e0998dbf30ceecd8f8e2022-12-21T18:15:18ZengWolters Kluwer Medknow PublicationsAnnals of Cardiac Anaesthesia0971-97842020-01-0123444745210.4103/aca.ACA_143_19Transesophageal probe placement increases endotracheal tube cuff pressure but is not associated with postoperative extubation failure after congenital cardiac surgeryStephanie J PanStephen Z FrabitoreAngela R IngramKhoa N NguyenPhillip S AdamsContext: The concomitant use of cuffed endotracheal tubes (ETT) and transesophageal echocardiography (TEE) probes increases ETT cuff pressures (CP), which may contribute to mucosal ischemia and perioperative complications such as failed extubation. Aims: To assess changes in ETT CP after TEE insertion in patients of different age groups undergoing congenital heart surgery and examine the relationship between ETT CP and postoperative extubation failure. Settings and Design: Single-center quality improvement project. Subjects and Methods: ETT CP was measured with a manometer following intubation and again after TEE insertion. Tracheal perfusion pressure was then calculated and postoperative extubation failures were recorded. Statistical Analysis: Chi-square testing, Fisher's-exact testing, one-way analysis of variance testing or Kruskal–Wallis testing with Dunn's pairwise, and student's t-test or Wilcoxon rank-sum testing were used to analyze the data. Results: Median ETT CP increased significantly after TEE insertion in each age group, with infants showing a smaller magnitude of increase (+2 [1-6] cm H2O, P < 0.001) than adults (+12 [8-14] cm H2O, P = 0.008) (intergroup comparison P = 0.002). Five patients (9%) failed extubation, all of which were infants. Within the infant subgroup, no significant difference existed between failed vs successful extubation regarding ETT CP during bypass (15 ± 1 vs 16 ± 2 mmHg, P = 0.206) or tracheal perfusion pressure pre-bypass (34 ± 9 vs 38 ± 11 mmHg, P = 0.518), during bypass (20 ± 9 vs 22 ± 6 mmHg, P = 0.697), or post-bypass (42 ± 9 vs 41 ± 9 mmHg, P = 0.923). There was a significant difference in cardiopulmonary bypass duration (151 ± 29 vs 85 ± 32 min, P < 0.001). Conclusion: Factors beyond intraoperative ETT CP likely play a larger role in postoperative extubation failure.http://www.annals.in/article.asp?issn=0971-9784;year=2020;volume=23;issue=4;spage=447;epage=452;aulast=Pancongenital cardiac anesthesiaendotracheal cuff pressureextubation failuretransesophageal echocardiography |
spellingShingle | Stephanie J Pan Stephen Z Frabitore Angela R Ingram Khoa N Nguyen Phillip S Adams Transesophageal probe placement increases endotracheal tube cuff pressure but is not associated with postoperative extubation failure after congenital cardiac surgery Annals of Cardiac Anaesthesia congenital cardiac anesthesia endotracheal cuff pressure extubation failure transesophageal echocardiography |
title | Transesophageal probe placement increases endotracheal tube cuff pressure but is not associated with postoperative extubation failure after congenital cardiac surgery |
title_full | Transesophageal probe placement increases endotracheal tube cuff pressure but is not associated with postoperative extubation failure after congenital cardiac surgery |
title_fullStr | Transesophageal probe placement increases endotracheal tube cuff pressure but is not associated with postoperative extubation failure after congenital cardiac surgery |
title_full_unstemmed | Transesophageal probe placement increases endotracheal tube cuff pressure but is not associated with postoperative extubation failure after congenital cardiac surgery |
title_short | Transesophageal probe placement increases endotracheal tube cuff pressure but is not associated with postoperative extubation failure after congenital cardiac surgery |
title_sort | transesophageal probe placement increases endotracheal tube cuff pressure but is not associated with postoperative extubation failure after congenital cardiac surgery |
topic | congenital cardiac anesthesia endotracheal cuff pressure extubation failure transesophageal echocardiography |
url | http://www.annals.in/article.asp?issn=0971-9784;year=2020;volume=23;issue=4;spage=447;epage=452;aulast=Pan |
work_keys_str_mv | AT stephaniejpan transesophagealprobeplacementincreasesendotrachealtubecuffpressurebutisnotassociatedwithpostoperativeextubationfailureaftercongenitalcardiacsurgery AT stephenzfrabitore transesophagealprobeplacementincreasesendotrachealtubecuffpressurebutisnotassociatedwithpostoperativeextubationfailureaftercongenitalcardiacsurgery AT angelaringram transesophagealprobeplacementincreasesendotrachealtubecuffpressurebutisnotassociatedwithpostoperativeextubationfailureaftercongenitalcardiacsurgery AT khoannguyen transesophagealprobeplacementincreasesendotrachealtubecuffpressurebutisnotassociatedwithpostoperativeextubationfailureaftercongenitalcardiacsurgery AT phillipsadams transesophagealprobeplacementincreasesendotrachealtubecuffpressurebutisnotassociatedwithpostoperativeextubationfailureaftercongenitalcardiacsurgery |