Effects of Applying Different Resonance Amplitude on the Performance of the Impedance-Based Health Monitoring Technique Subjected to Damage

Smart materials such as piezoelectric transducers can be used for monitoring the health of building structures. In this study, a structural health monitoring technique known as the electromechanical impedance (EMI) method is investigated. Although the EMI method has the advantage of using a single p...

Full description

Bibliographic Details
Main Authors: Wongi S. Na, Dong-Woo Seo, Byeong-Cheol Kim, Ki-Tae Park
Format: Article
Language:English
Published: MDPI AG 2018-07-01
Series:Sensors
Subjects:
Online Access:http://www.mdpi.com/1424-8220/18/7/2267
_version_ 1798025787323973632
author Wongi S. Na
Dong-Woo Seo
Byeong-Cheol Kim
Ki-Tae Park
author_facet Wongi S. Na
Dong-Woo Seo
Byeong-Cheol Kim
Ki-Tae Park
author_sort Wongi S. Na
collection DOAJ
description Smart materials such as piezoelectric transducers can be used for monitoring the health of building structures. In this study, a structural health monitoring technique known as the electromechanical impedance (EMI) method is investigated. Although the EMI method has the advantage of using a single piezoelectric patch that acts both as the actuator and as the sensor, there are still many issues to be addressed. To further understand the problem, the performance of the EMI method on a structure subjected to progressive damage at different resonance frequency ranges and peak amplitudes was investigated using three different statistical metrics: root-mean-square deviation (RMSD), mean absolute percentage deviation (MAPD) and correlation coefficient deviation (CCD). Metal plates were used throughout the study. The results acquired could be used to further understand the damage identification performance of the EMI method.
first_indexed 2024-04-11T18:24:25Z
format Article
id doaj.art-a61836e25d8b4032b7d3d1706cbb472c
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-04-11T18:24:25Z
publishDate 2018-07-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-a61836e25d8b4032b7d3d1706cbb472c2022-12-22T04:09:41ZengMDPI AGSensors1424-82202018-07-01187226710.3390/s18072267s18072267Effects of Applying Different Resonance Amplitude on the Performance of the Impedance-Based Health Monitoring Technique Subjected to DamageWongi S. Na0Dong-Woo Seo1Byeong-Cheol Kim2Ki-Tae Park3Sustainable Infrastructure Research Center, Korea Institute of Civil Engineering & Building Technology (KICT), Gyeonggi-Do 10223, KoreaSustainable Infrastructure Research Center, Korea Institute of Civil Engineering & Building Technology (KICT), Gyeonggi-Do 10223, KoreaSustainable Infrastructure Research Center, Korea Institute of Civil Engineering & Building Technology (KICT), Gyeonggi-Do 10223, KoreaSustainable Infrastructure Research Center, Korea Institute of Civil Engineering & Building Technology (KICT), Gyeonggi-Do 10223, KoreaSmart materials such as piezoelectric transducers can be used for monitoring the health of building structures. In this study, a structural health monitoring technique known as the electromechanical impedance (EMI) method is investigated. Although the EMI method has the advantage of using a single piezoelectric patch that acts both as the actuator and as the sensor, there are still many issues to be addressed. To further understand the problem, the performance of the EMI method on a structure subjected to progressive damage at different resonance frequency ranges and peak amplitudes was investigated using three different statistical metrics: root-mean-square deviation (RMSD), mean absolute percentage deviation (MAPD) and correlation coefficient deviation (CCD). Metal plates were used throughout the study. The results acquired could be used to further understand the damage identification performance of the EMI method.http://www.mdpi.com/1424-8220/18/7/2267electromechanical impedancepiezoelectric transducerdamage detectionstructural health monitoringnondestructive testing
spellingShingle Wongi S. Na
Dong-Woo Seo
Byeong-Cheol Kim
Ki-Tae Park
Effects of Applying Different Resonance Amplitude on the Performance of the Impedance-Based Health Monitoring Technique Subjected to Damage
Sensors
electromechanical impedance
piezoelectric transducer
damage detection
structural health monitoring
nondestructive testing
title Effects of Applying Different Resonance Amplitude on the Performance of the Impedance-Based Health Monitoring Technique Subjected to Damage
title_full Effects of Applying Different Resonance Amplitude on the Performance of the Impedance-Based Health Monitoring Technique Subjected to Damage
title_fullStr Effects of Applying Different Resonance Amplitude on the Performance of the Impedance-Based Health Monitoring Technique Subjected to Damage
title_full_unstemmed Effects of Applying Different Resonance Amplitude on the Performance of the Impedance-Based Health Monitoring Technique Subjected to Damage
title_short Effects of Applying Different Resonance Amplitude on the Performance of the Impedance-Based Health Monitoring Technique Subjected to Damage
title_sort effects of applying different resonance amplitude on the performance of the impedance based health monitoring technique subjected to damage
topic electromechanical impedance
piezoelectric transducer
damage detection
structural health monitoring
nondestructive testing
url http://www.mdpi.com/1424-8220/18/7/2267
work_keys_str_mv AT wongisna effectsofapplyingdifferentresonanceamplitudeontheperformanceoftheimpedancebasedhealthmonitoringtechniquesubjectedtodamage
AT dongwooseo effectsofapplyingdifferentresonanceamplitudeontheperformanceoftheimpedancebasedhealthmonitoringtechniquesubjectedtodamage
AT byeongcheolkim effectsofapplyingdifferentresonanceamplitudeontheperformanceoftheimpedancebasedhealthmonitoringtechniquesubjectedtodamage
AT kitaepark effectsofapplyingdifferentresonanceamplitudeontheperformanceoftheimpedancebasedhealthmonitoringtechniquesubjectedtodamage