User-centered virtual environment design for virtual rehabilitation

<p>Abstract</p> <p>Background</p> <p>As physical and cognitive rehabilitation protocols utilizing virtual environments transition from single applications to comprehensive rehabilitation programs there is a need for a new design cycle methodology. Current human-computer...

Full description

Bibliographic Details
Main Authors: Rizzo Albert A, Fidopiastis Cali M, Rolland Jannick P
Format: Article
Language:English
Published: BMC 2010-02-01
Series:Journal of NeuroEngineering and Rehabilitation
Online Access:http://www.jneuroengrehab.com/content/7/1/11
_version_ 1818117551532539904
author Rizzo Albert A
Fidopiastis Cali M
Rolland Jannick P
author_facet Rizzo Albert A
Fidopiastis Cali M
Rolland Jannick P
author_sort Rizzo Albert A
collection DOAJ
description <p>Abstract</p> <p>Background</p> <p>As physical and cognitive rehabilitation protocols utilizing virtual environments transition from single applications to comprehensive rehabilitation programs there is a need for a new design cycle methodology. Current human-computer interaction designs focus on usability without benchmarking technology within a user-in-the-loop design cycle. The field of virtual rehabilitation is unique in that determining the efficacy of this genre of computer-aided therapies requires prior knowledge of technology issues that may confound patient outcome measures. Benchmarking the technology (e.g., displays or data gloves) using healthy controls may provide a means of characterizing the "normal" performance range of the virtual rehabilitation system. This standard not only allows therapists to select appropriate technology for use with their patient populations, it also allows them to account for technology limitations when assessing treatment efficacy.</p> <p>Methods</p> <p>An overview of the proposed user-centered design cycle is given. Comparisons of two optical see-through head-worn displays provide an example of benchmarking techniques. Benchmarks were obtained using a novel vision test capable of measuring a user's stereoacuity while wearing different types of head-worn displays. Results from healthy participants who performed both virtual and real-world versions of the stereoacuity test are discussed with respect to virtual rehabilitation design.</p> <p>Results</p> <p>The user-centered design cycle argues for benchmarking to precede virtual environment construction, especially for therapeutic applications. Results from real-world testing illustrate the general limitations in stereoacuity attained when viewing content using a head-worn display. Further, the stereoacuity vision benchmark test highlights differences in user performance when utilizing a similar style of head-worn display. These results support the need for including benchmarks as a means of better understanding user outcomes, especially for patient populations.</p> <p>Conclusions</p> <p>The stereoacuity testing confirms that without benchmarking in the design cycle poor user performance could be misconstrued as resulting from the participant's injury state. Thus, a user-centered design cycle that includes benchmarking for the different sensory modalities is recommended for accurate interpretation of the efficacy of the virtual environment based rehabilitation programs.</p>
first_indexed 2024-12-11T04:40:13Z
format Article
id doaj.art-a61aae27090440c9b673e03bde322904
institution Directory Open Access Journal
issn 1743-0003
language English
last_indexed 2024-12-11T04:40:13Z
publishDate 2010-02-01
publisher BMC
record_format Article
series Journal of NeuroEngineering and Rehabilitation
spelling doaj.art-a61aae27090440c9b673e03bde3229042022-12-22T01:20:38ZengBMCJournal of NeuroEngineering and Rehabilitation1743-00032010-02-01711110.1186/1743-0003-7-11User-centered virtual environment design for virtual rehabilitationRizzo Albert AFidopiastis Cali MRolland Jannick P<p>Abstract</p> <p>Background</p> <p>As physical and cognitive rehabilitation protocols utilizing virtual environments transition from single applications to comprehensive rehabilitation programs there is a need for a new design cycle methodology. Current human-computer interaction designs focus on usability without benchmarking technology within a user-in-the-loop design cycle. The field of virtual rehabilitation is unique in that determining the efficacy of this genre of computer-aided therapies requires prior knowledge of technology issues that may confound patient outcome measures. Benchmarking the technology (e.g., displays or data gloves) using healthy controls may provide a means of characterizing the "normal" performance range of the virtual rehabilitation system. This standard not only allows therapists to select appropriate technology for use with their patient populations, it also allows them to account for technology limitations when assessing treatment efficacy.</p> <p>Methods</p> <p>An overview of the proposed user-centered design cycle is given. Comparisons of two optical see-through head-worn displays provide an example of benchmarking techniques. Benchmarks were obtained using a novel vision test capable of measuring a user's stereoacuity while wearing different types of head-worn displays. Results from healthy participants who performed both virtual and real-world versions of the stereoacuity test are discussed with respect to virtual rehabilitation design.</p> <p>Results</p> <p>The user-centered design cycle argues for benchmarking to precede virtual environment construction, especially for therapeutic applications. Results from real-world testing illustrate the general limitations in stereoacuity attained when viewing content using a head-worn display. Further, the stereoacuity vision benchmark test highlights differences in user performance when utilizing a similar style of head-worn display. These results support the need for including benchmarks as a means of better understanding user outcomes, especially for patient populations.</p> <p>Conclusions</p> <p>The stereoacuity testing confirms that without benchmarking in the design cycle poor user performance could be misconstrued as resulting from the participant's injury state. Thus, a user-centered design cycle that includes benchmarking for the different sensory modalities is recommended for accurate interpretation of the efficacy of the virtual environment based rehabilitation programs.</p>http://www.jneuroengrehab.com/content/7/1/11
spellingShingle Rizzo Albert A
Fidopiastis Cali M
Rolland Jannick P
User-centered virtual environment design for virtual rehabilitation
Journal of NeuroEngineering and Rehabilitation
title User-centered virtual environment design for virtual rehabilitation
title_full User-centered virtual environment design for virtual rehabilitation
title_fullStr User-centered virtual environment design for virtual rehabilitation
title_full_unstemmed User-centered virtual environment design for virtual rehabilitation
title_short User-centered virtual environment design for virtual rehabilitation
title_sort user centered virtual environment design for virtual rehabilitation
url http://www.jneuroengrehab.com/content/7/1/11
work_keys_str_mv AT rizzoalberta usercenteredvirtualenvironmentdesignforvirtualrehabilitation
AT fidopiastiscalim usercenteredvirtualenvironmentdesignforvirtualrehabilitation
AT rollandjannickp usercenteredvirtualenvironmentdesignforvirtualrehabilitation