Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems.

Microstructure imaging techniques based on tensor-valued diffusion encoding have gained popularity within the MRI research community. Unlike conventional diffusion encoding-applied along a single direction in each shot-tensor-valued encoding employs diffusion encoding along multiple directions withi...

Full description

Bibliographic Details
Main Authors: Filip Szczepankiewicz, Jens Sjölund, Freddy Ståhlberg, Jimmy Lätt, Markus Nilsson
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2019-01-01
Series:PLoS ONE
Online Access:https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0214238&type=printable
_version_ 1826576868210376704
author Filip Szczepankiewicz
Jens Sjölund
Freddy Ståhlberg
Jimmy Lätt
Markus Nilsson
author_facet Filip Szczepankiewicz
Jens Sjölund
Freddy Ståhlberg
Jimmy Lätt
Markus Nilsson
author_sort Filip Szczepankiewicz
collection DOAJ
description Microstructure imaging techniques based on tensor-valued diffusion encoding have gained popularity within the MRI research community. Unlike conventional diffusion encoding-applied along a single direction in each shot-tensor-valued encoding employs diffusion encoding along multiple directions within a single preparation of the signal. The benefit is that such encoding may probe tissue features that are not accessible by conventional encoding. For example, diffusional variance decomposition (DIVIDE) takes advantage of tensor-valued encoding to probe microscopic diffusion anisotropy independent of orientation coherence. The drawback is that tensor-valued encoding generally requires gradient waveforms that are more demanding on hardware; it has therefore been used primarily in MRI systems with relatively high performance. The purpose of this work was to explore tensor-valued diffusion encoding on clinical MRI systems with varying performance to test its technical feasibility within the context of DIVIDE. We performed whole-brain imaging with linear and spherical b-tensor encoding at field strengths between 1.5 and 7 T, and at maximal gradient amplitudes between 45 and 80 mT/m. Asymmetric gradient waveforms were optimized numerically to yield b-values up to 2 ms/μm2. Technical feasibility was assessed in terms of the repeatability, SNR, and quality of DIVIDE parameter maps. Variable system performance resulted in echo times between 83 to 115 ms and total acquisition times of 6 to 9 minutes when using 80 signal samples and resolution 2×2×4 mm3. As expected, the repeatability, signal-to-noise ratio and parameter map quality depended on hardware performance. We conclude that tensor-valued encoding is feasible for a wide range of MRI systems-even at 1.5 T with maximal gradient waveform amplitudes of 33 mT/m-and baseline experimental design and quality parameters for all included configurations. This demonstrates that tissue features, beyond those accessible by conventional diffusion encoding, can be explored on a wide range of MRI systems.
first_indexed 2024-12-20T02:33:36Z
format Article
id doaj.art-a694ec26baad4bebbef0a199f46adaf5
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2025-03-14T13:37:26Z
publishDate 2019-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-a694ec26baad4bebbef0a199f46adaf52025-02-28T05:31:48ZengPublic Library of Science (PLoS)PLoS ONE1932-62032019-01-01143e021423810.1371/journal.pone.0214238Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems.Filip SzczepankiewiczJens SjölundFreddy StåhlbergJimmy LättMarkus NilssonMicrostructure imaging techniques based on tensor-valued diffusion encoding have gained popularity within the MRI research community. Unlike conventional diffusion encoding-applied along a single direction in each shot-tensor-valued encoding employs diffusion encoding along multiple directions within a single preparation of the signal. The benefit is that such encoding may probe tissue features that are not accessible by conventional encoding. For example, diffusional variance decomposition (DIVIDE) takes advantage of tensor-valued encoding to probe microscopic diffusion anisotropy independent of orientation coherence. The drawback is that tensor-valued encoding generally requires gradient waveforms that are more demanding on hardware; it has therefore been used primarily in MRI systems with relatively high performance. The purpose of this work was to explore tensor-valued diffusion encoding on clinical MRI systems with varying performance to test its technical feasibility within the context of DIVIDE. We performed whole-brain imaging with linear and spherical b-tensor encoding at field strengths between 1.5 and 7 T, and at maximal gradient amplitudes between 45 and 80 mT/m. Asymmetric gradient waveforms were optimized numerically to yield b-values up to 2 ms/μm2. Technical feasibility was assessed in terms of the repeatability, SNR, and quality of DIVIDE parameter maps. Variable system performance resulted in echo times between 83 to 115 ms and total acquisition times of 6 to 9 minutes when using 80 signal samples and resolution 2×2×4 mm3. As expected, the repeatability, signal-to-noise ratio and parameter map quality depended on hardware performance. We conclude that tensor-valued encoding is feasible for a wide range of MRI systems-even at 1.5 T with maximal gradient waveform amplitudes of 33 mT/m-and baseline experimental design and quality parameters for all included configurations. This demonstrates that tissue features, beyond those accessible by conventional diffusion encoding, can be explored on a wide range of MRI systems.https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0214238&type=printable
spellingShingle Filip Szczepankiewicz
Jens Sjölund
Freddy Ståhlberg
Jimmy Lätt
Markus Nilsson
Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems.
PLoS ONE
title Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems.
title_full Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems.
title_fullStr Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems.
title_full_unstemmed Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems.
title_short Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems.
title_sort tensor valued diffusion encoding for diffusional variance decomposition divide technical feasibility in clinical mri systems
url https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0214238&type=printable
work_keys_str_mv AT filipszczepankiewicz tensorvalueddiffusionencodingfordiffusionalvariancedecompositiondividetechnicalfeasibilityinclinicalmrisystems
AT jenssjolund tensorvalueddiffusionencodingfordiffusionalvariancedecompositiondividetechnicalfeasibilityinclinicalmrisystems
AT freddystahlberg tensorvalueddiffusionencodingfordiffusionalvariancedecompositiondividetechnicalfeasibilityinclinicalmrisystems
AT jimmylatt tensorvalueddiffusionencodingfordiffusionalvariancedecompositiondividetechnicalfeasibilityinclinicalmrisystems
AT markusnilsson tensorvalueddiffusionencodingfordiffusionalvariancedecompositiondividetechnicalfeasibilityinclinicalmrisystems