Cyclic Behavior of High-Strength Lightweight Concrete Exterior Beam-Column Connections Reinforced with GFRP

Using lightweight reinforced concrete beams with glass fiber bars (GFRP) is one approach for achieving the requirement seismic design idea of “strong-columns weak-beams”. Twelve full-scale normal-strength concrete (NC with <i>f<sub>c</sub>`</i> = 32 MPa) and high-strength lig...

Full description

Bibliographic Details
Main Authors: Mahmoud A. El-Mandouh, Mostafa. S. Omar, Mohamed A. Elnaggar, Ahmed S. Abd El-Maula
Format: Article
Language:English
Published: MDPI AG 2022-02-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/12/2/179
_version_ 1797482158497988608
author Mahmoud A. El-Mandouh
Mostafa. S. Omar
Mohamed A. Elnaggar
Ahmed S. Abd El-Maula
author_facet Mahmoud A. El-Mandouh
Mostafa. S. Omar
Mohamed A. Elnaggar
Ahmed S. Abd El-Maula
author_sort Mahmoud A. El-Mandouh
collection DOAJ
description Using lightweight reinforced concrete beams with glass fiber bars (GFRP) is one approach for achieving the requirement seismic design idea of “strong-columns weak-beams”. Twelve full-scale normal-strength concrete (NC with <i>f<sub>c</sub>`</i> = 32 MPa) and high-strength lightweight concrete (HSLWC with <i>f<sub>c</sub>`</i> = 42, 49 and 52 MPa) exterior beam-column joints have been tested under cyclic loadings. The beams were reinforced with conventional steel bars (CS) and GFRP using steel fibers (SF). The experimental joint shear force was compared with that estimated by some international codes such as the American Concrete Institute (ACI-19), the Egyptian code (ECP-07), and the New Zealand Code (NZS-06). Nonlinear finite element analysis (ABAQUS) was carried out. In the present study, three main parameters were explored (1) HSLWC, (2) GFRP ratios equal to 0.70%, 1.03% and 1.37%, (3) SF ratios equal to 0.0%, 0.75% and 1.50%. The findings of the experiment revealed that increasing the concrete strength from NC with conventional steel bars to high-strength lightweight concrete HSLWC (<i>f<sub>c</sub>`</i> = 42 MPa) with the same ratio of GFRP bars enhanced the first cracking load by about 25%. Increasing the SF ratio to 1.50% enhanced the failure load by 18–24% when compared with non-fiber specimens. The predicted joint shear strength estimated using the equations of the ACI 318-19 and ECP-07 are conservative for HSLWC exterior beam-column connection reinforced with GFRP bars but the predicted joint shear strength by using the equations of the NZS-07 is on the borderline for some cases. The finite element program ABAQUS can be used successfully to forecast the behavior of HSLWC beam-column connections reinforced with GFRP under seismic loadings.
first_indexed 2024-03-09T22:26:17Z
format Article
id doaj.art-a696f4ecad314c16b288ae7d485336e4
institution Directory Open Access Journal
issn 2075-5309
language English
last_indexed 2024-03-09T22:26:17Z
publishDate 2022-02-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj.art-a696f4ecad314c16b288ae7d485336e42023-11-23T19:06:11ZengMDPI AGBuildings2075-53092022-02-0112217910.3390/buildings12020179Cyclic Behavior of High-Strength Lightweight Concrete Exterior Beam-Column Connections Reinforced with GFRPMahmoud A. El-Mandouh0Mostafa. S. Omar1Mohamed A. Elnaggar2Ahmed S. Abd El-Maula3Civil Construction Department, Beni-Suef University, Beni-Suef 62511, EgyptHigher Institute for Engineering and Technology, Department of Structural Engineering, Behira 22511, EgyptStructural Engineering Department, Faculty of Engineering, Alexandria University, Alexandria 21519, EgyptFaculty of Engineering, Delta University for Science and Technology, Gamasa 35712, EgyptUsing lightweight reinforced concrete beams with glass fiber bars (GFRP) is one approach for achieving the requirement seismic design idea of “strong-columns weak-beams”. Twelve full-scale normal-strength concrete (NC with <i>f<sub>c</sub>`</i> = 32 MPa) and high-strength lightweight concrete (HSLWC with <i>f<sub>c</sub>`</i> = 42, 49 and 52 MPa) exterior beam-column joints have been tested under cyclic loadings. The beams were reinforced with conventional steel bars (CS) and GFRP using steel fibers (SF). The experimental joint shear force was compared with that estimated by some international codes such as the American Concrete Institute (ACI-19), the Egyptian code (ECP-07), and the New Zealand Code (NZS-06). Nonlinear finite element analysis (ABAQUS) was carried out. In the present study, three main parameters were explored (1) HSLWC, (2) GFRP ratios equal to 0.70%, 1.03% and 1.37%, (3) SF ratios equal to 0.0%, 0.75% and 1.50%. The findings of the experiment revealed that increasing the concrete strength from NC with conventional steel bars to high-strength lightweight concrete HSLWC (<i>f<sub>c</sub>`</i> = 42 MPa) with the same ratio of GFRP bars enhanced the first cracking load by about 25%. Increasing the SF ratio to 1.50% enhanced the failure load by 18–24% when compared with non-fiber specimens. The predicted joint shear strength estimated using the equations of the ACI 318-19 and ECP-07 are conservative for HSLWC exterior beam-column connection reinforced with GFRP bars but the predicted joint shear strength by using the equations of the NZS-07 is on the borderline for some cases. The finite element program ABAQUS can be used successfully to forecast the behavior of HSLWC beam-column connections reinforced with GFRP under seismic loadings.https://www.mdpi.com/2075-5309/12/2/179beam-columnlightweight concreteglass fiber reinforcementjoint shear
spellingShingle Mahmoud A. El-Mandouh
Mostafa. S. Omar
Mohamed A. Elnaggar
Ahmed S. Abd El-Maula
Cyclic Behavior of High-Strength Lightweight Concrete Exterior Beam-Column Connections Reinforced with GFRP
Buildings
beam-column
lightweight concrete
glass fiber reinforcement
joint shear
title Cyclic Behavior of High-Strength Lightweight Concrete Exterior Beam-Column Connections Reinforced with GFRP
title_full Cyclic Behavior of High-Strength Lightweight Concrete Exterior Beam-Column Connections Reinforced with GFRP
title_fullStr Cyclic Behavior of High-Strength Lightweight Concrete Exterior Beam-Column Connections Reinforced with GFRP
title_full_unstemmed Cyclic Behavior of High-Strength Lightweight Concrete Exterior Beam-Column Connections Reinforced with GFRP
title_short Cyclic Behavior of High-Strength Lightweight Concrete Exterior Beam-Column Connections Reinforced with GFRP
title_sort cyclic behavior of high strength lightweight concrete exterior beam column connections reinforced with gfrp
topic beam-column
lightweight concrete
glass fiber reinforcement
joint shear
url https://www.mdpi.com/2075-5309/12/2/179
work_keys_str_mv AT mahmoudaelmandouh cyclicbehaviorofhighstrengthlightweightconcreteexteriorbeamcolumnconnectionsreinforcedwithgfrp
AT mostafasomar cyclicbehaviorofhighstrengthlightweightconcreteexteriorbeamcolumnconnectionsreinforcedwithgfrp
AT mohamedaelnaggar cyclicbehaviorofhighstrengthlightweightconcreteexteriorbeamcolumnconnectionsreinforcedwithgfrp
AT ahmedsabdelmaula cyclicbehaviorofhighstrengthlightweightconcreteexteriorbeamcolumnconnectionsreinforcedwithgfrp