CLINICAL STUDIES OF MATERIALS FOR TEMPORARY REMOVABLE PROSTHESIS

One of the important parts of the temporary prosthesis is to develop new polymeric materials dental appointment with a given combination of required properties: antibacterial activity, reduced shrinkage, high strength and adhesive properties. To make an effective choice of material should we must...

Full description

Bibliographic Details
Main Author: O.S. Kyrmanov
Format: Article
Language:English
Published: Ukrainian Medical Stomatological Academy 2015-03-01
Series:Український стоматологічний альманах
Subjects:
Online Access:https://dental-almanac.org/index.php/journal/article/view/48
_version_ 1818752852631224320
author O.S. Kyrmanov
author_facet O.S. Kyrmanov
author_sort O.S. Kyrmanov
collection DOAJ
description One of the important parts of the temporary prosthesis is to develop new polymeric materials dental appointment with a given combination of required properties: antibacterial activity, reduced shrinkage, high strength and adhesive properties. To make an effective choice of material should we must have complete information not only about their mechanical and chemical, but also about their clinical characteristics too. Clinical studies consider aspects such as process manufacturing, fitting, setting temporary cement, the development of dental plaque, gingivitis, color resistance and subjective perception provisionally material as doctor and patient. Declared in dental literature light curing mechanical properties of composite materials and dual-curing is not always supported by the inconvenience for manual processing. Due to the polymerization shrinkage inherent in these materials, it is difficult to achieve accuracy between occlusal relationships. For this reason, all materials look better than subjective evaluation of the work performed dentist than according to their mechanical properties or opinions patient. In writings [14] investigated the marginal fit and color fastness structures of the two self-curing materials "Protemp Garant" and "Integrity", a dual-curing composite "Luxatemp Solar", using material of polymethylmethacrylate "SNAP" as a control. Provisional material dual cure "Luxatemp Solar" showed more rejection edges fit than bisacryl materials or "SNAP". In "Protemp Garant" hue change observed after 1 week stay in solution of tea, although other materials did not show clinically significant changes. Extra embryonic materials have antibacterial properties. We investigated the antibacterial properties "Revotek", "Tempit", "Systemp" and "IRM" immediately after curing at 1, 7, 14 and 30 days of aging in artificial saliva solution in phosphate buffer [15]. Structures "Tempit", "Systemp" and "IRM" showed antibacterial properties in contact with S. mutans at least 7 days, and "Tempit" and "IRM" supported this resolution 14 days. In contact with E. faecalis "Tempit" and "IRM" have antibacterial properties immediately after hardening. "IRM" to save this property just 1 day. Thus revealed different material properties that can affect what microorganisms are able to penetrate into the root canal system. Bacterial adhesion and formation of dental plaque manifests itself during gingival inflammation and the development of secondary caries. Researchers compared the state of surface hydrophobicity and 10 temporary fixation materials of different composition, as well as their ability to perceive Streptococcus mutans [16]. Number of different bacterial adhesion to all materials applied provisionally. High fluorescence intensity (> 10,000) was found for "Snap", "UniFastLC" and "CronMix K plus", the average values (5000-10,000) for the "Trim", "Temphase", "Structur Premium" and "PreVISION CB" and the lowest fluorescence intensity (<5000) were found for "Cronsin", "Protemp" and "Luxatemp". Streptococci monolayers corresponding initial bacterial adhesion were found in all studied surfaces. To reduce the negative impact of high polymerization temperature better use previous silicone impression because impression materials takes too much heat. This aspect is particularly important if there is a large middle part of the design and replaced a large amount of hard substance of the tooth (crown thick walls).
first_indexed 2024-12-18T04:58:03Z
format Article
id doaj.art-a6eaf051bace40cc807dd7b7f57fb027
institution Directory Open Access Journal
issn 2409-0255
2410-1427
language English
last_indexed 2024-12-18T04:58:03Z
publishDate 2015-03-01
publisher Ukrainian Medical Stomatological Academy
record_format Article
series Український стоматологічний альманах
spelling doaj.art-a6eaf051bace40cc807dd7b7f57fb0272022-12-21T21:20:14ZengUkrainian Medical Stomatological AcademyУкраїнський стоматологічний альманах2409-02552410-14272015-03-013667048CLINICAL STUDIES OF MATERIALS FOR TEMPORARY REMOVABLE PROSTHESISO.S. Kyrmanov0Department of Prosthetic Dentistry, Danylo Halytskyi Lviv National Medical UniversityOne of the important parts of the temporary prosthesis is to develop new polymeric materials dental appointment with a given combination of required properties: antibacterial activity, reduced shrinkage, high strength and adhesive properties. To make an effective choice of material should we must have complete information not only about their mechanical and chemical, but also about their clinical characteristics too. Clinical studies consider aspects such as process manufacturing, fitting, setting temporary cement, the development of dental plaque, gingivitis, color resistance and subjective perception provisionally material as doctor and patient. Declared in dental literature light curing mechanical properties of composite materials and dual-curing is not always supported by the inconvenience for manual processing. Due to the polymerization shrinkage inherent in these materials, it is difficult to achieve accuracy between occlusal relationships. For this reason, all materials look better than subjective evaluation of the work performed dentist than according to their mechanical properties or opinions patient. In writings [14] investigated the marginal fit and color fastness structures of the two self-curing materials "Protemp Garant" and "Integrity", a dual-curing composite "Luxatemp Solar", using material of polymethylmethacrylate "SNAP" as a control. Provisional material dual cure "Luxatemp Solar" showed more rejection edges fit than bisacryl materials or "SNAP". In "Protemp Garant" hue change observed after 1 week stay in solution of tea, although other materials did not show clinically significant changes. Extra embryonic materials have antibacterial properties. We investigated the antibacterial properties "Revotek", "Tempit", "Systemp" and "IRM" immediately after curing at 1, 7, 14 and 30 days of aging in artificial saliva solution in phosphate buffer [15]. Structures "Tempit", "Systemp" and "IRM" showed antibacterial properties in contact with S. mutans at least 7 days, and "Tempit" and "IRM" supported this resolution 14 days. In contact with E. faecalis "Tempit" and "IRM" have antibacterial properties immediately after hardening. "IRM" to save this property just 1 day. Thus revealed different material properties that can affect what microorganisms are able to penetrate into the root canal system. Bacterial adhesion and formation of dental plaque manifests itself during gingival inflammation and the development of secondary caries. Researchers compared the state of surface hydrophobicity and 10 temporary fixation materials of different composition, as well as their ability to perceive Streptococcus mutans [16]. Number of different bacterial adhesion to all materials applied provisionally. High fluorescence intensity (> 10,000) was found for "Snap", "UniFastLC" and "CronMix K plus", the average values (5000-10,000) for the "Trim", "Temphase", "Structur Premium" and "PreVISION CB" and the lowest fluorescence intensity (<5000) were found for "Cronsin", "Protemp" and "Luxatemp". Streptococci monolayers corresponding initial bacterial adhesion were found in all studied surfaces. To reduce the negative impact of high polymerization temperature better use previous silicone impression because impression materials takes too much heat. This aspect is particularly important if there is a large middle part of the design and replaced a large amount of hard substance of the tooth (crown thick walls).https://dental-almanac.org/index.php/journal/article/view/48рlastics for temporary prosthesis
spellingShingle O.S. Kyrmanov
CLINICAL STUDIES OF MATERIALS FOR TEMPORARY REMOVABLE PROSTHESIS
Український стоматологічний альманах
рlastics for temporary prosthesis
title CLINICAL STUDIES OF MATERIALS FOR TEMPORARY REMOVABLE PROSTHESIS
title_full CLINICAL STUDIES OF MATERIALS FOR TEMPORARY REMOVABLE PROSTHESIS
title_fullStr CLINICAL STUDIES OF MATERIALS FOR TEMPORARY REMOVABLE PROSTHESIS
title_full_unstemmed CLINICAL STUDIES OF MATERIALS FOR TEMPORARY REMOVABLE PROSTHESIS
title_short CLINICAL STUDIES OF MATERIALS FOR TEMPORARY REMOVABLE PROSTHESIS
title_sort clinical studies of materials for temporary removable prosthesis
topic рlastics for temporary prosthesis
url https://dental-almanac.org/index.php/journal/article/view/48
work_keys_str_mv AT oskyrmanov clinicalstudiesofmaterialsfortemporaryremovableprosthesis