The Reduction of Metal Artifacts using Band Pass Median Filter on Head Ct Scan
Background: One of the artifacts found on the CT scan is a metal artifact. Metal artifacts are caused by metal objects present in patients’ bodies. The file of metal artifacts can cover the organ that will be evaluated, and it can be inferred with the pixel value (CT number) assessment of the tissue...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | Indonesian |
Published: |
Universitas Airlangga
2022-07-01
|
Series: | Journal of Vocational Health Studies |
Subjects: | |
Online Access: | https://e-journal.unair.ac.id/JVHS/article/view/24182 |
_version_ | 1818172847541977088 |
---|---|
author | Nimas Rokhmatik Dayyana Pramono Khusnul Ain Amilia Kartikasari Riky Tri Yunardi |
author_facet | Nimas Rokhmatik Dayyana Pramono Khusnul Ain Amilia Kartikasari Riky Tri Yunardi |
author_sort | Nimas Rokhmatik Dayyana |
collection | DOAJ |
description | Background: One of the artifacts found on the CT scan is a metal artifact. Metal artifacts are caused by metal objects present in patients’ bodies. The file of metal artifacts can cover the organ that will be evaluated, and it can be inferred with the pixel value (CT number) assessment of the tissue around the metal. Purpose: To determine the effect of the band pass median filter and find the optimal filter to reduce metal artifacts on the head CT scan. Method: A total of 43 samples of patients’s files from head CT-scan without any contrast were reconstructed using four band pass median filters and obtained R1, R2, R5, and R10 filters. Two radiology specialists were assessed for the reduction of metal artifacts using the ImageJ application. Result: Four variations of the filter affected the reduction of metal artifacts because the band pass median filter maintained a point that was close to its neighboring points and points that were different from its neighboring points by replacing the value of the pixel with the median value of the grey level of neighboring pixels. The optimal filter recommendation is the R1 filter because it has the largest SNR value (16.9773) and the smallest RMSE value (8.57501) so that the result of the image is more informative and has a diagnostic value. Conclusion: The four filter variations were affected by reducing metal artifacts. Images with substantial SNR and fractional RMSE values produced an image that was more informative and still had diagnostic value. |
first_indexed | 2024-12-11T19:19:07Z |
format | Article |
id | doaj.art-a6ec20d04f874a6eb621cc92c8b19f07 |
institution | Directory Open Access Journal |
issn | 2580-7161 2580-717X |
language | Indonesian |
last_indexed | 2024-12-11T19:19:07Z |
publishDate | 2022-07-01 |
publisher | Universitas Airlangga |
record_format | Article |
series | Journal of Vocational Health Studies |
spelling | doaj.art-a6ec20d04f874a6eb621cc92c8b19f072022-12-22T00:53:35ZindUniversitas AirlanggaJournal of Vocational Health Studies2580-71612580-717X2022-07-0161172310.20473/jvhs.V6.I1.2022.17-23The Reduction of Metal Artifacts using Band Pass Median Filter on Head Ct ScanNimas Rokhmatik Dayyana0https://orcid.org/0000-0002-4118-2299Pramono1https://orcid.org/0000-0002-2131-2156Khusnul Ain2https://orcid.org/0000-0002-8315-7067Amilia Kartikasari3https://orcid.org/0000-0001-9908-3974Riky Tri Yunardi4https://orcid.org/0000-0002-8780-1198Department of Health, Faculty of Vocational Studies, Universitas Airlangga, IndonesiaDepartment of Radiology, Dr. Soetomo Hospital, IndonesiaDepartment of Physics, Faculty of Science and Technology, Universitas Airlangga, IndonesiaDepartment of Health, Faculty of Vocational Studies, Universitas Airlangga, IndonesiaDepartment of Engineering, Faculty of Vocational Studies, Universitas Airlangga, IndonesiaBackground: One of the artifacts found on the CT scan is a metal artifact. Metal artifacts are caused by metal objects present in patients’ bodies. The file of metal artifacts can cover the organ that will be evaluated, and it can be inferred with the pixel value (CT number) assessment of the tissue around the metal. Purpose: To determine the effect of the band pass median filter and find the optimal filter to reduce metal artifacts on the head CT scan. Method: A total of 43 samples of patients’s files from head CT-scan without any contrast were reconstructed using four band pass median filters and obtained R1, R2, R5, and R10 filters. Two radiology specialists were assessed for the reduction of metal artifacts using the ImageJ application. Result: Four variations of the filter affected the reduction of metal artifacts because the band pass median filter maintained a point that was close to its neighboring points and points that were different from its neighboring points by replacing the value of the pixel with the median value of the grey level of neighboring pixels. The optimal filter recommendation is the R1 filter because it has the largest SNR value (16.9773) and the smallest RMSE value (8.57501) so that the result of the image is more informative and has a diagnostic value. Conclusion: The four filter variations were affected by reducing metal artifacts. Images with substantial SNR and fractional RMSE values produced an image that was more informative and still had diagnostic value.https://e-journal.unair.ac.id/JVHS/article/view/24182artifact reductionband pass median filterhead ct scanmetal artifacts |
spellingShingle | Nimas Rokhmatik Dayyana Pramono Khusnul Ain Amilia Kartikasari Riky Tri Yunardi The Reduction of Metal Artifacts using Band Pass Median Filter on Head Ct Scan Journal of Vocational Health Studies artifact reduction band pass median filter head ct scan metal artifacts |
title | The Reduction of Metal Artifacts using Band Pass Median Filter on Head Ct Scan |
title_full | The Reduction of Metal Artifacts using Band Pass Median Filter on Head Ct Scan |
title_fullStr | The Reduction of Metal Artifacts using Band Pass Median Filter on Head Ct Scan |
title_full_unstemmed | The Reduction of Metal Artifacts using Band Pass Median Filter on Head Ct Scan |
title_short | The Reduction of Metal Artifacts using Band Pass Median Filter on Head Ct Scan |
title_sort | reduction of metal artifacts using band pass median filter on head ct scan |
topic | artifact reduction band pass median filter head ct scan metal artifacts |
url | https://e-journal.unair.ac.id/JVHS/article/view/24182 |
work_keys_str_mv | AT nimasrokhmatikdayyana thereductionofmetalartifactsusingbandpassmedianfilteronheadctscan AT pramono thereductionofmetalartifactsusingbandpassmedianfilteronheadctscan AT khusnulain thereductionofmetalartifactsusingbandpassmedianfilteronheadctscan AT amiliakartikasari thereductionofmetalartifactsusingbandpassmedianfilteronheadctscan AT rikytriyunardi thereductionofmetalartifactsusingbandpassmedianfilteronheadctscan AT nimasrokhmatikdayyana reductionofmetalartifactsusingbandpassmedianfilteronheadctscan AT pramono reductionofmetalartifactsusingbandpassmedianfilteronheadctscan AT khusnulain reductionofmetalartifactsusingbandpassmedianfilteronheadctscan AT amiliakartikasari reductionofmetalartifactsusingbandpassmedianfilteronheadctscan AT rikytriyunardi reductionofmetalartifactsusingbandpassmedianfilteronheadctscan |