Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT
Abstract Aim of this study was to assess the impact of virtual monoenergetic images (VMI) in combination and comparison with iterative metal artifact reduction (IMAR) on hip prosthesis-associated artifacts in photon-counting detector CT (PCD-CT). Retrospectively, 33 scans with hip prosthesis-associa...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Nature Portfolio
2023-06-01
|
Series: | Scientific Reports |
Online Access: | https://doi.org/10.1038/s41598-023-35989-6 |
_version_ | 1827933422343946240 |
---|---|
author | Yannik C. Layer Narine Mesropyan Patrick A. Kupczyk Julian A. Luetkens Alexander Isaak Tatjana Dell Ulrike I. Attenberger Daniel Kuetting |
author_facet | Yannik C. Layer Narine Mesropyan Patrick A. Kupczyk Julian A. Luetkens Alexander Isaak Tatjana Dell Ulrike I. Attenberger Daniel Kuetting |
author_sort | Yannik C. Layer |
collection | DOAJ |
description | Abstract Aim of this study was to assess the impact of virtual monoenergetic images (VMI) in combination and comparison with iterative metal artifact reduction (IMAR) on hip prosthesis-associated artifacts in photon-counting detector CT (PCD-CT). Retrospectively, 33 scans with hip prosthesis-associated artifacts acquired during clinical routine on a PCD-CT between 08/2022 and 09/2022 were analyzed. VMI were reconstructed for 100–190 keV with and without IMAR, and compared to polychromatic images. Qualitatively, artifact extent and assessment of adjacent soft tissue were rated by two radiologists using 5-point Likert items. Quantitative assessment was performed measuring attenuation and standard deviation in most pronounced hypodense and hyperdense artifacts, artifact-impaired bone, muscle, vessels, bladder and artifact-free corresponding tissue. To quantify artifacts, an adjusted attenuation was calculated as the difference between artifact-impaired tissue and corresponding tissue without artifacts. Qualitative assessment improved for all investigated image reconstructions compared to polychromatic images (PI). VMI100keV in combination with IMAR achieved best results (e.g. diagnostic quality of the bladder: median PI: 1.5 (range 1–4); VMI100keV+IMAR: 5 (3–5); p < 0.0001). In quantitative assessment VMI100keV with IMAR provided best artifact reduction with an adjusted attenuation closest to 0 (e.g. bone: PI: 302.78; VMI100keV+IMAR: 51.18; p < 0.0001). The combination of VMI and IMAR significantly reduces hip prosthesis-associated artifacts in PCD-CT and improves the diagnostic quality of surrounding tissue. |
first_indexed | 2024-03-13T07:24:34Z |
format | Article |
id | doaj.art-a6fc0f206b2c4519889a7805e13ae05c |
institution | Directory Open Access Journal |
issn | 2045-2322 |
language | English |
last_indexed | 2024-03-13T07:24:34Z |
publishDate | 2023-06-01 |
publisher | Nature Portfolio |
record_format | Article |
series | Scientific Reports |
spelling | doaj.art-a6fc0f206b2c4519889a7805e13ae05c2023-06-04T11:27:42ZengNature PortfolioScientific Reports2045-23222023-06-0113111110.1038/s41598-023-35989-6Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CTYannik C. Layer0Narine Mesropyan1Patrick A. Kupczyk2Julian A. Luetkens3Alexander Isaak4Tatjana Dell5Ulrike I. Attenberger6Daniel Kuetting7Department of Diagnostic and Interventional Radiology, University Hospital BonnDepartment of Diagnostic and Interventional Radiology, University Hospital BonnDepartment of Diagnostic and Interventional Radiology, University Hospital BonnDepartment of Diagnostic and Interventional Radiology, University Hospital BonnDepartment of Diagnostic and Interventional Radiology, University Hospital BonnDepartment of Diagnostic and Interventional Radiology, University Hospital BonnDepartment of Diagnostic and Interventional Radiology, University Hospital BonnDepartment of Diagnostic and Interventional Radiology, University Hospital BonnAbstract Aim of this study was to assess the impact of virtual monoenergetic images (VMI) in combination and comparison with iterative metal artifact reduction (IMAR) on hip prosthesis-associated artifacts in photon-counting detector CT (PCD-CT). Retrospectively, 33 scans with hip prosthesis-associated artifacts acquired during clinical routine on a PCD-CT between 08/2022 and 09/2022 were analyzed. VMI were reconstructed for 100–190 keV with and without IMAR, and compared to polychromatic images. Qualitatively, artifact extent and assessment of adjacent soft tissue were rated by two radiologists using 5-point Likert items. Quantitative assessment was performed measuring attenuation and standard deviation in most pronounced hypodense and hyperdense artifacts, artifact-impaired bone, muscle, vessels, bladder and artifact-free corresponding tissue. To quantify artifacts, an adjusted attenuation was calculated as the difference between artifact-impaired tissue and corresponding tissue without artifacts. Qualitative assessment improved for all investigated image reconstructions compared to polychromatic images (PI). VMI100keV in combination with IMAR achieved best results (e.g. diagnostic quality of the bladder: median PI: 1.5 (range 1–4); VMI100keV+IMAR: 5 (3–5); p < 0.0001). In quantitative assessment VMI100keV with IMAR provided best artifact reduction with an adjusted attenuation closest to 0 (e.g. bone: PI: 302.78; VMI100keV+IMAR: 51.18; p < 0.0001). The combination of VMI and IMAR significantly reduces hip prosthesis-associated artifacts in PCD-CT and improves the diagnostic quality of surrounding tissue.https://doi.org/10.1038/s41598-023-35989-6 |
spellingShingle | Yannik C. Layer Narine Mesropyan Patrick A. Kupczyk Julian A. Luetkens Alexander Isaak Tatjana Dell Ulrike I. Attenberger Daniel Kuetting Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT Scientific Reports |
title | Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT |
title_full | Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT |
title_fullStr | Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT |
title_full_unstemmed | Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT |
title_short | Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT |
title_sort | combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis associated artifacts in photon counting detector ct |
url | https://doi.org/10.1038/s41598-023-35989-6 |
work_keys_str_mv | AT yannikclayer combiningiterativemetalartifactreductionandvirtualmonoenergeticimagesseverelyreduceshipprosthesisassociatedartifactsinphotoncountingdetectorct AT narinemesropyan combiningiterativemetalartifactreductionandvirtualmonoenergeticimagesseverelyreduceshipprosthesisassociatedartifactsinphotoncountingdetectorct AT patrickakupczyk combiningiterativemetalartifactreductionandvirtualmonoenergeticimagesseverelyreduceshipprosthesisassociatedartifactsinphotoncountingdetectorct AT julianaluetkens combiningiterativemetalartifactreductionandvirtualmonoenergeticimagesseverelyreduceshipprosthesisassociatedartifactsinphotoncountingdetectorct AT alexanderisaak combiningiterativemetalartifactreductionandvirtualmonoenergeticimagesseverelyreduceshipprosthesisassociatedartifactsinphotoncountingdetectorct AT tatjanadell combiningiterativemetalartifactreductionandvirtualmonoenergeticimagesseverelyreduceshipprosthesisassociatedartifactsinphotoncountingdetectorct AT ulrikeiattenberger combiningiterativemetalartifactreductionandvirtualmonoenergeticimagesseverelyreduceshipprosthesisassociatedartifactsinphotoncountingdetectorct AT danielkuetting combiningiterativemetalartifactreductionandvirtualmonoenergeticimagesseverelyreduceshipprosthesisassociatedartifactsinphotoncountingdetectorct |