Inspection for non-planar shaped welded joints of pipes using FMC ultrasonic technique
In applying ultrasonic testing (UT) to pipes with welded joints, one of the challenges is about the access limitation of UT probes caused by non-planar weld reinforcement profiles. One way to avoid this problem is to remove weld reinforcement for ensuring the contactability of a probe on welded par...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | deu |
Published: |
NDT.net
2023-08-01
|
Series: | e-Journal of Nondestructive Testing |
Online Access: | https://www.ndt.net/search/docs.php3?id=28212 |