Numerical Analysis of Thermal Impact between the Cooling Facility and the Ground
The article presents the results of research on the range of the impact of a cooling facility on the surrounding ground. An analysis of the heat exchange with the ground and through the building partitions was carried out. The analysis was carried out on the basis of the results of actual field test...
Main Authors: | Paweł Sokołowski, Grzegorz Nawalany, Tomasz Jakubowski, Ernest Popardowski, Vasyl Lopushniak, Atilgan Atilgan |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2022-12-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/15/24/9338 |
Similar Items
-
Numerical Analysis of the Effect of Floor Depression on the Extent of Thermal Interaction with the Ground and Energy Management Using a Vegetable Cold Store as an Example
by: Paweł Sokołowski, et al.
Published: (2023-12-01) -
Analysis of Greenhouse Gas Emissions and Energy Consumption Depending on the Material and Construction Solutions and the Energy Carrier Used—A Case Study
by: Grzegorz Nawalany, et al.
Published: (2024-12-01) -
Interaction between a Cyclically Heated Building and the Ground, for Selected Locations in Europe
by: Grzegorz Nawalany, et al.
Published: (2022-10-01) -
Analysis of Energy Exchange with the Ground in a Two-Chamber Vegetable Cold Store, Assuming Different Lengths of Technological Break, with the Use of a Numerical Calculation Method—A Case Study
by: Paweł Sokołowski, et al.
Published: (2020-09-01) -
Analysis of the Operation of an Unheated Wooden Church to the Shaping of Thermal and Humidity Conditions Using the Numerical Method
by: Grzegorz Nawalany, et al.
Published: (2021-08-01)