Research on the GIC Governance Scheme of the Xinjiang 750-kV Power Grid Based on an Equal Allocation Method
The damage caused to power grid by geomagnetic storm increases with an increase in the grid voltage level and an increase in the grid coverage area. Xinjiang is a vast, high-latitude area in China, where geomagnetically induced currents (GIC) have an enormous effect on geomagnetic storm. The voltage...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2020-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/9075223/ |
_version_ | 1818379603398361088 |
---|---|
author | Shu-Ming Zhang Lian-Guang Liu |
author_facet | Shu-Ming Zhang Lian-Guang Liu |
author_sort | Shu-Ming Zhang |
collection | DOAJ |
description | The damage caused to power grid by geomagnetic storm increases with an increase in the grid voltage level and an increase in the grid coverage area. Xinjiang is a vast, high-latitude area in China, where geomagnetically induced currents (GIC) have an enormous effect on geomagnetic storm. The voltage level of the Xinjiang power grid (750 kV) and the DC resistance of the grid are small, which aggravates the impact of GICs on the power grid. During geomagnetic storm, the safety and stability of the Xinjiang power grid is crucial. But Xinjiang power grid supplies power for a large range of area, and the grid structure is mostly connected by single transmission line. Therefore, the power grid is relatively weak in resisting accidents and has high operational risk. In this paper, Xinjiang's 750-kV power grid was chosen as a research object, and a GIC governance method (a shared governance method) is proposed. The Xinjiang power grid's control over GIC effects was analyzed, and the effectiveness of the method was verified using simulations. |
first_indexed | 2024-12-14T02:05:25Z |
format | Article |
id | doaj.art-a7ec00ee52864704931e4925cef9b3fd |
institution | Directory Open Access Journal |
issn | 2169-3536 |
language | English |
last_indexed | 2024-12-14T02:05:25Z |
publishDate | 2020-01-01 |
publisher | IEEE |
record_format | Article |
series | IEEE Access |
spelling | doaj.art-a7ec00ee52864704931e4925cef9b3fd2022-12-21T23:20:54ZengIEEEIEEE Access2169-35362020-01-018754197542710.1109/ACCESS.2020.29891679075223Research on the GIC Governance Scheme of the Xinjiang 750-kV Power Grid Based on an Equal Allocation MethodShu-Ming Zhang0https://orcid.org/0000-0001-9794-6465Lian-Guang Liu1State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, ChinaThe damage caused to power grid by geomagnetic storm increases with an increase in the grid voltage level and an increase in the grid coverage area. Xinjiang is a vast, high-latitude area in China, where geomagnetically induced currents (GIC) have an enormous effect on geomagnetic storm. The voltage level of the Xinjiang power grid (750 kV) and the DC resistance of the grid are small, which aggravates the impact of GICs on the power grid. During geomagnetic storm, the safety and stability of the Xinjiang power grid is crucial. But Xinjiang power grid supplies power for a large range of area, and the grid structure is mostly connected by single transmission line. Therefore, the power grid is relatively weak in resisting accidents and has high operational risk. In this paper, Xinjiang's 750-kV power grid was chosen as a research object, and a GIC governance method (a shared governance method) is proposed. The Xinjiang power grid's control over GIC effects was analyzed, and the effectiveness of the method was verified using simulations.https://ieeexplore.ieee.org/document/9075223/Xinjiang power grid750-kVGIC governancesharing method |
spellingShingle | Shu-Ming Zhang Lian-Guang Liu Research on the GIC Governance Scheme of the Xinjiang 750-kV Power Grid Based on an Equal Allocation Method IEEE Access Xinjiang power grid 750-kV GIC governance sharing method |
title | Research on the GIC Governance Scheme of the Xinjiang 750-kV Power Grid Based on an Equal Allocation Method |
title_full | Research on the GIC Governance Scheme of the Xinjiang 750-kV Power Grid Based on an Equal Allocation Method |
title_fullStr | Research on the GIC Governance Scheme of the Xinjiang 750-kV Power Grid Based on an Equal Allocation Method |
title_full_unstemmed | Research on the GIC Governance Scheme of the Xinjiang 750-kV Power Grid Based on an Equal Allocation Method |
title_short | Research on the GIC Governance Scheme of the Xinjiang 750-kV Power Grid Based on an Equal Allocation Method |
title_sort | research on the gic governance scheme of the xinjiang 750 kv power grid based on an equal allocation method |
topic | Xinjiang power grid 750-kV GIC governance sharing method |
url | https://ieeexplore.ieee.org/document/9075223/ |
work_keys_str_mv | AT shumingzhang researchonthegicgovernanceschemeofthexinjiang750kvpowergridbasedonanequalallocationmethod AT lianguangliu researchonthegicgovernanceschemeofthexinjiang750kvpowergridbasedonanequalallocationmethod |