Bedside intravascular ultrasound-guided fibrin sheath balloon maceration and inferior vena cava filter placement during extracorporeal membranous oxygenation decannulation
Inferior vena cava filter placement during extracorporeal membranous oxygenation decannulation has been described as a technique to prevent potentially lethal pulmonary embolism in this critically ill population. With long-standing extracorporeal membranous oxygenation cannulae, venous fibrin sheath...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2020-03-01
|
Series: | Journal of Vascular Surgery Cases and Innovative Techniques |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2468428719301418 |
_version_ | 1818542547008487424 |
---|---|
author | William M. Sherk, MD Minhaj S. Khaja, MD, MBA Alexandria Jo, MD Xhorlina Marko, MD David M. Williams, MD |
author_facet | William M. Sherk, MD Minhaj S. Khaja, MD, MBA Alexandria Jo, MD Xhorlina Marko, MD David M. Williams, MD |
author_sort | William M. Sherk, MD |
collection | DOAJ |
description | Inferior vena cava filter placement during extracorporeal membranous oxygenation decannulation has been described as a technique to prevent potentially lethal pulmonary embolism in this critically ill population. With long-standing extracorporeal membranous oxygenation cannulae, venous fibrin sheaths may develop, which may predispose to filter maldeployment or inadequate embolus filtration. This report describes the use of a balloon catheter to disrupt a fibrin sheath at patient bedside using intravascular ultrasound guidance to facilitate inferior vena cava filter placement. Keywords: ECMO, IVC filter, Fibrin sheath, IVUS |
first_indexed | 2024-12-11T22:23:30Z |
format | Article |
id | doaj.art-a8ce65d63da34835978d093bb9aca08e |
institution | Directory Open Access Journal |
issn | 2468-4287 |
language | English |
last_indexed | 2024-12-11T22:23:30Z |
publishDate | 2020-03-01 |
publisher | Elsevier |
record_format | Article |
series | Journal of Vascular Surgery Cases and Innovative Techniques |
spelling | doaj.art-a8ce65d63da34835978d093bb9aca08e2022-12-22T00:48:22ZengElsevierJournal of Vascular Surgery Cases and Innovative Techniques2468-42872020-03-01615658Bedside intravascular ultrasound-guided fibrin sheath balloon maceration and inferior vena cava filter placement during extracorporeal membranous oxygenation decannulationWilliam M. Sherk, MD0Minhaj S. Khaja, MD, MBA1Alexandria Jo, MD2Xhorlina Marko, MD3David M. Williams, MD4Division of Vascular and Interventional Radiology, Department of Radiology, University of Michigan Health Systems, Ann Arbor, MichCorrespondence: Minhaj S. Khaja, MD, MBA, Division of Vascular and Interventional Radiology, University of Michigan Health System, 1500 East Medical Center Dr, Ann Arbor, MI 48109; Division of Vascular and Interventional Radiology, Department of Radiology, University of Michigan Health Systems, Ann Arbor, MichDivision of Vascular and Interventional Radiology, Department of Radiology, University of Michigan Health Systems, Ann Arbor, MichDivision of Vascular and Interventional Radiology, Department of Radiology, University of Michigan Health Systems, Ann Arbor, MichDivision of Vascular and Interventional Radiology, Department of Radiology, University of Michigan Health Systems, Ann Arbor, MichInferior vena cava filter placement during extracorporeal membranous oxygenation decannulation has been described as a technique to prevent potentially lethal pulmonary embolism in this critically ill population. With long-standing extracorporeal membranous oxygenation cannulae, venous fibrin sheaths may develop, which may predispose to filter maldeployment or inadequate embolus filtration. This report describes the use of a balloon catheter to disrupt a fibrin sheath at patient bedside using intravascular ultrasound guidance to facilitate inferior vena cava filter placement. Keywords: ECMO, IVC filter, Fibrin sheath, IVUShttp://www.sciencedirect.com/science/article/pii/S2468428719301418 |
spellingShingle | William M. Sherk, MD Minhaj S. Khaja, MD, MBA Alexandria Jo, MD Xhorlina Marko, MD David M. Williams, MD Bedside intravascular ultrasound-guided fibrin sheath balloon maceration and inferior vena cava filter placement during extracorporeal membranous oxygenation decannulation Journal of Vascular Surgery Cases and Innovative Techniques |
title | Bedside intravascular ultrasound-guided fibrin sheath balloon maceration and inferior vena cava filter placement during extracorporeal membranous oxygenation decannulation |
title_full | Bedside intravascular ultrasound-guided fibrin sheath balloon maceration and inferior vena cava filter placement during extracorporeal membranous oxygenation decannulation |
title_fullStr | Bedside intravascular ultrasound-guided fibrin sheath balloon maceration and inferior vena cava filter placement during extracorporeal membranous oxygenation decannulation |
title_full_unstemmed | Bedside intravascular ultrasound-guided fibrin sheath balloon maceration and inferior vena cava filter placement during extracorporeal membranous oxygenation decannulation |
title_short | Bedside intravascular ultrasound-guided fibrin sheath balloon maceration and inferior vena cava filter placement during extracorporeal membranous oxygenation decannulation |
title_sort | bedside intravascular ultrasound guided fibrin sheath balloon maceration and inferior vena cava filter placement during extracorporeal membranous oxygenation decannulation |
url | http://www.sciencedirect.com/science/article/pii/S2468428719301418 |
work_keys_str_mv | AT williammsherkmd bedsideintravascularultrasoundguidedfibrinsheathballoonmacerationandinferiorvenacavafilterplacementduringextracorporealmembranousoxygenationdecannulation AT minhajskhajamdmba bedsideintravascularultrasoundguidedfibrinsheathballoonmacerationandinferiorvenacavafilterplacementduringextracorporealmembranousoxygenationdecannulation AT alexandriajomd bedsideintravascularultrasoundguidedfibrinsheathballoonmacerationandinferiorvenacavafilterplacementduringextracorporealmembranousoxygenationdecannulation AT xhorlinamarkomd bedsideintravascularultrasoundguidedfibrinsheathballoonmacerationandinferiorvenacavafilterplacementduringextracorporealmembranousoxygenationdecannulation AT davidmwilliamsmd bedsideintravascularultrasoundguidedfibrinsheathballoonmacerationandinferiorvenacavafilterplacementduringextracorporealmembranousoxygenationdecannulation |