DECT Numbers in Upper Abdominal Organs for Differential Diagnosis: A Feasibility Study

Evaluating the similarity between two entities such as primary and suspected metastatic lesions using quantitative dual-energy computed tomography (DECT) numbers may be useful. However, the criteria for the similarity between two entities based on DECT numbers remain unclear. We therefore considered...

Full description

Bibliographic Details
Main Authors: Fumihito Toshima, Norihide Yoneda, Kanako Terada, Dai Inoue, Toshifumi Gabata
Format: Article
Language:English
Published: MDPI AG 2022-11-01
Series:Tomography
Subjects:
Online Access:https://www.mdpi.com/2379-139X/8/6/225
_version_ 1827636818653216768
author Fumihito Toshima
Norihide Yoneda
Kanako Terada
Dai Inoue
Toshifumi Gabata
author_facet Fumihito Toshima
Norihide Yoneda
Kanako Terada
Dai Inoue
Toshifumi Gabata
author_sort Fumihito Toshima
collection DOAJ
description Evaluating the similarity between two entities such as primary and suspected metastatic lesions using quantitative dual-energy computed tomography (DECT) numbers may be useful. However, the criteria for the similarity between two entities based on DECT numbers remain unclear. We therefore considered the possibility that a similarity in DECT numbers within the same organ could provide suitable standards. Thus, we assumed that the variation in DECT numbers within a single organ is sufficiently minimal to be considered clinically equivalent. Therefore, the purpose of this preliminary study is to investigate the differences in DECT numbers within upper abdominal organs. This retrospective study included 30 patients with data from hepatic protocol DECT scans. DECT numbers of the following parameters were collected: (a, b) 70 and 40 keV CT values, (c) slope, (d) effective Z, and (e, f) iodine and water concentration. The agreement of DECT numbers obtained from two regions of interest in the same organ (liver, spleen, and kidney) were assessed using Bland–Altman analysis. The diagnostic ability of each DECT parameter to distinguish between the same or different organs was also assessed using receiver operating characteristic analysis. The 95% limits of agreement within the same organ exhibited the narrowest value range on delayed phase (DP) CT [(c) −11.2–8.3%, (d) −2.0–1.5%, (e) −11.3–8.4%, and (f) −0.59–0.62%]. The diagnostic ability was notably high when using differences in DECT numbers on portal venous (PVP) and DP images (the area under the curve of DP: 0.987–0.999 in (c)–(f)). Using the variability in DECT numbers in the same organ as a criterion for defining similarity may be helpful in making a differential diagnosis by comparing the DECT numbers of two entities.
first_indexed 2024-03-09T15:47:55Z
format Article
id doaj.art-a8d021ca696e49909ab644ddd4e87655
institution Directory Open Access Journal
issn 2379-1381
2379-139X
language English
last_indexed 2024-03-09T15:47:55Z
publishDate 2022-11-01
publisher MDPI AG
record_format Article
series Tomography
spelling doaj.art-a8d021ca696e49909ab644ddd4e876552023-11-24T18:23:55ZengMDPI AGTomography2379-13812379-139X2022-11-01862698270810.3390/tomography8060225DECT Numbers in Upper Abdominal Organs for Differential Diagnosis: A Feasibility StudyFumihito Toshima0Norihide Yoneda1Kanako Terada2Dai Inoue3Toshifumi Gabata4Department of Radiology, Kanazawa University Graduate School of Medical Sciences, 13-1, Takara-Machi, Kanazawa 920-8641, Ishikawa, JapanDepartment of Radiology, Kanazawa University Graduate School of Medical Sciences, 13-1, Takara-Machi, Kanazawa 920-8641, Ishikawa, JapanDepartment of Radiology, Kanazawa University Graduate School of Medical Sciences, 13-1, Takara-Machi, Kanazawa 920-8641, Ishikawa, JapanDepartment of Radiology, Kanazawa University Graduate School of Medical Sciences, 13-1, Takara-Machi, Kanazawa 920-8641, Ishikawa, JapanDepartment of Radiology, Kanazawa University Graduate School of Medical Sciences, 13-1, Takara-Machi, Kanazawa 920-8641, Ishikawa, JapanEvaluating the similarity between two entities such as primary and suspected metastatic lesions using quantitative dual-energy computed tomography (DECT) numbers may be useful. However, the criteria for the similarity between two entities based on DECT numbers remain unclear. We therefore considered the possibility that a similarity in DECT numbers within the same organ could provide suitable standards. Thus, we assumed that the variation in DECT numbers within a single organ is sufficiently minimal to be considered clinically equivalent. Therefore, the purpose of this preliminary study is to investigate the differences in DECT numbers within upper abdominal organs. This retrospective study included 30 patients with data from hepatic protocol DECT scans. DECT numbers of the following parameters were collected: (a, b) 70 and 40 keV CT values, (c) slope, (d) effective Z, and (e, f) iodine and water concentration. The agreement of DECT numbers obtained from two regions of interest in the same organ (liver, spleen, and kidney) were assessed using Bland–Altman analysis. The diagnostic ability of each DECT parameter to distinguish between the same or different organs was also assessed using receiver operating characteristic analysis. The 95% limits of agreement within the same organ exhibited the narrowest value range on delayed phase (DP) CT [(c) −11.2–8.3%, (d) −2.0–1.5%, (e) −11.3–8.4%, and (f) −0.59–0.62%]. The diagnostic ability was notably high when using differences in DECT numbers on portal venous (PVP) and DP images (the area under the curve of DP: 0.987–0.999 in (c)–(f)). Using the variability in DECT numbers in the same organ as a criterion for defining similarity may be helpful in making a differential diagnosis by comparing the DECT numbers of two entities.https://www.mdpi.com/2379-139X/8/6/225dual-energy computed tomographycomputed tomography attenuation curveeffective Ziodine concentrationwater concentrationDECT numbers
spellingShingle Fumihito Toshima
Norihide Yoneda
Kanako Terada
Dai Inoue
Toshifumi Gabata
DECT Numbers in Upper Abdominal Organs for Differential Diagnosis: A Feasibility Study
Tomography
dual-energy computed tomography
computed tomography attenuation curve
effective Z
iodine concentration
water concentration
DECT numbers
title DECT Numbers in Upper Abdominal Organs for Differential Diagnosis: A Feasibility Study
title_full DECT Numbers in Upper Abdominal Organs for Differential Diagnosis: A Feasibility Study
title_fullStr DECT Numbers in Upper Abdominal Organs for Differential Diagnosis: A Feasibility Study
title_full_unstemmed DECT Numbers in Upper Abdominal Organs for Differential Diagnosis: A Feasibility Study
title_short DECT Numbers in Upper Abdominal Organs for Differential Diagnosis: A Feasibility Study
title_sort dect numbers in upper abdominal organs for differential diagnosis a feasibility study
topic dual-energy computed tomography
computed tomography attenuation curve
effective Z
iodine concentration
water concentration
DECT numbers
url https://www.mdpi.com/2379-139X/8/6/225
work_keys_str_mv AT fumihitotoshima dectnumbersinupperabdominalorgansfordifferentialdiagnosisafeasibilitystudy
AT norihideyoneda dectnumbersinupperabdominalorgansfordifferentialdiagnosisafeasibilitystudy
AT kanakoterada dectnumbersinupperabdominalorgansfordifferentialdiagnosisafeasibilitystudy
AT daiinoue dectnumbersinupperabdominalorgansfordifferentialdiagnosisafeasibilitystudy
AT toshifumigabata dectnumbersinupperabdominalorgansfordifferentialdiagnosisafeasibilitystudy