Research on Loading Scheme for Large-Scale Model Tests of Super-Long-Span Arch Bridge
A reasonable and efficient loading scheme is needed to guarantee the success of large-scale bridge tests. In this study, an array-type, self-balancing pulley-group loading system was designed based on the world’s largest spanning arch bridge using a 1:10 scale model test. Automatic statistics of the...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2023-06-01
|
Series: | Buildings |
Subjects: | |
Online Access: | https://www.mdpi.com/2075-5309/13/7/1639 |
_version_ | 1797590048334413824 |
---|---|
author | Yonghui Fan Jianting Zhou Chao Luo Jun Yang Jingzhou Xin Shaorui Wang |
author_facet | Yonghui Fan Jianting Zhou Chao Luo Jun Yang Jingzhou Xin Shaorui Wang |
author_sort | Yonghui Fan |
collection | DOAJ |
description | A reasonable and efficient loading scheme is needed to guarantee the success of large-scale bridge tests. In this study, an array-type, self-balancing pulley-group loading system was designed based on the world’s largest spanning arch bridge using a 1:10 scale model test. Automatic statistics of the required load at each loading point were realized using ANSYS, and a load optimization algorithm for loading points at different construction stages was proposed. Tests were carried out separately for the loading system using a single set of pulley groups and an array-type pulley group. Finite element models of the model bridge and the original bridge were established separately using ANSYS, and the stress results of different components during different construction stages of the main arch ring were compared. The research results show the following: (1) The load magnification factor of the single-pulley-group loading device is approximately 6.6 times, with a mechanical efficiency of 94.26%. (2) In the array-type loading system, the actual load at each loading point can reach the design value. The self-balancing characteristic of this system can eliminate the impact of vertical deformation of the structure on loading accuracy, verifying the reliability of the system. (3) The simulation results of the original bridge and the model bridge coincide well, and the stress of each component during the construction process has the same trend. At key construction stages, the maximum relative errors of the stress results of the rigid steel frame and the concrete inside the pipe of the two bridges are 8.33% and 9.34%, respectively, and the maximum absolute error of the bottom plate concrete is 0.66 MPa, verifying the correctness of the counterweight-optimization method. The loading scheme proposed in this paper can provide a reference for the design of loading systems with the same type of scale model test. |
first_indexed | 2024-03-11T01:14:51Z |
format | Article |
id | doaj.art-a8e19387977c4af9839dd7b143eef4e1 |
institution | Directory Open Access Journal |
issn | 2075-5309 |
language | English |
last_indexed | 2024-03-11T01:14:51Z |
publishDate | 2023-06-01 |
publisher | MDPI AG |
record_format | Article |
series | Buildings |
spelling | doaj.art-a8e19387977c4af9839dd7b143eef4e12023-11-18T18:36:39ZengMDPI AGBuildings2075-53092023-06-01137163910.3390/buildings13071639Research on Loading Scheme for Large-Scale Model Tests of Super-Long-Span Arch BridgeYonghui Fan0Jianting Zhou1Chao Luo2Jun Yang3Jingzhou Xin4Shaorui Wang5State Key Laboratory of Mountain Bridge and Tunnel Engineering, Chongqing Jiaotong University, Chongqing 400074, ChinaState Key Laboratory of Mountain Bridge and Tunnel Engineering, Chongqing Jiaotong University, Chongqing 400074, ChinaState Key Laboratory of Mountain Bridge and Tunnel Engineering, Chongqing Jiaotong University, Chongqing 400074, ChinaState Key Laboratory of Mountain Bridge and Tunnel Engineering, Chongqing Jiaotong University, Chongqing 400074, ChinaState Key Laboratory of Mountain Bridge and Tunnel Engineering, Chongqing Jiaotong University, Chongqing 400074, ChinaState Key Laboratory of Mountain Bridge and Tunnel Engineering, Chongqing Jiaotong University, Chongqing 400074, ChinaA reasonable and efficient loading scheme is needed to guarantee the success of large-scale bridge tests. In this study, an array-type, self-balancing pulley-group loading system was designed based on the world’s largest spanning arch bridge using a 1:10 scale model test. Automatic statistics of the required load at each loading point were realized using ANSYS, and a load optimization algorithm for loading points at different construction stages was proposed. Tests were carried out separately for the loading system using a single set of pulley groups and an array-type pulley group. Finite element models of the model bridge and the original bridge were established separately using ANSYS, and the stress results of different components during different construction stages of the main arch ring were compared. The research results show the following: (1) The load magnification factor of the single-pulley-group loading device is approximately 6.6 times, with a mechanical efficiency of 94.26%. (2) In the array-type loading system, the actual load at each loading point can reach the design value. The self-balancing characteristic of this system can eliminate the impact of vertical deformation of the structure on loading accuracy, verifying the reliability of the system. (3) The simulation results of the original bridge and the model bridge coincide well, and the stress of each component during the construction process has the same trend. At key construction stages, the maximum relative errors of the stress results of the rigid steel frame and the concrete inside the pipe of the two bridges are 8.33% and 9.34%, respectively, and the maximum absolute error of the bottom plate concrete is 0.66 MPa, verifying the correctness of the counterweight-optimization method. The loading scheme proposed in this paper can provide a reference for the design of loading systems with the same type of scale model test.https://www.mdpi.com/2075-5309/13/7/1639rigid-frame arch bridgescale model testtest designloading systemweight calculation method |
spellingShingle | Yonghui Fan Jianting Zhou Chao Luo Jun Yang Jingzhou Xin Shaorui Wang Research on Loading Scheme for Large-Scale Model Tests of Super-Long-Span Arch Bridge Buildings rigid-frame arch bridge scale model test test design loading system weight calculation method |
title | Research on Loading Scheme for Large-Scale Model Tests of Super-Long-Span Arch Bridge |
title_full | Research on Loading Scheme for Large-Scale Model Tests of Super-Long-Span Arch Bridge |
title_fullStr | Research on Loading Scheme for Large-Scale Model Tests of Super-Long-Span Arch Bridge |
title_full_unstemmed | Research on Loading Scheme for Large-Scale Model Tests of Super-Long-Span Arch Bridge |
title_short | Research on Loading Scheme for Large-Scale Model Tests of Super-Long-Span Arch Bridge |
title_sort | research on loading scheme for large scale model tests of super long span arch bridge |
topic | rigid-frame arch bridge scale model test test design loading system weight calculation method |
url | https://www.mdpi.com/2075-5309/13/7/1639 |
work_keys_str_mv | AT yonghuifan researchonloadingschemeforlargescalemodeltestsofsuperlongspanarchbridge AT jiantingzhou researchonloadingschemeforlargescalemodeltestsofsuperlongspanarchbridge AT chaoluo researchonloadingschemeforlargescalemodeltestsofsuperlongspanarchbridge AT junyang researchonloadingschemeforlargescalemodeltestsofsuperlongspanarchbridge AT jingzhouxin researchonloadingschemeforlargescalemodeltestsofsuperlongspanarchbridge AT shaoruiwang researchonloadingschemeforlargescalemodeltestsofsuperlongspanarchbridge |