BIOMECHANICAL ASPECTS OF IMPRESSIONS IN PARTIALLY EDENTULOUS

Aim of the study The aim of this study is to identify a crucial stage of treatment or functional fingerprint, quantify the factors underlying the choice of method of fingerprinting, according to the particularity of the prosthetic field, to ensure an optimal management of the removable prosthetic th...

Full description

Bibliographic Details
Main Authors: Cibela Caras, Doriana Agop, Norina Consuela Forna
Format: Article
Language:English
Published: Romanian Society of Oral Rehabilitation 2017-07-01
Series:Romanian Journal of Oral Rehabilitation
Subjects:
Online Access:http://www.rjor.ro/biomechanical-aspects-of-impressions-in-partially-edentulous/?lang=ro
_version_ 1819071561110388736
author Cibela Caras
Doriana Agop
Norina Consuela Forna
author_facet Cibela Caras
Doriana Agop
Norina Consuela Forna
author_sort Cibela Caras
collection DOAJ
description Aim of the study The aim of this study is to identify a crucial stage of treatment or functional fingerprint, quantify the factors underlying the choice of method of fingerprinting, according to the particularity of the prosthetic field, to ensure an optimal management of the removable prosthetic therapy. Material and methods Within the partially stretched edentulous several methods of functional fingerprinting were described, different from total edentulous, usually using certain criteria: edentulous class I, II, III, IV, Kennedy, V, VI, Kennedy Applegate, supporting prosthetic field muco-bone with high or low resilience; edentulous ridge with sharp or stationary resorption; type of prosthesis, type of occlusion – no contacts of dental decay, the presence of unstable dental decay , presence of a stabile dental impression .Results Particularities of the prosthetic field clinic-biological related to indices that characterize the odonto periodontal status and the muco-bone, are those that dictate the type of material chosen, the footprint viscosity imprint material or chosen technique. Conclusions : Functional fingerprinting is a very important clinical stage with a profound impact in producing the final prosthetic
first_indexed 2024-12-21T17:23:47Z
format Article
id doaj.art-a928ee3a5c75410e83a495277b9fe48d
institution Directory Open Access Journal
issn 2066-7000
2066-7000
language English
last_indexed 2024-12-21T17:23:47Z
publishDate 2017-07-01
publisher Romanian Society of Oral Rehabilitation
record_format Article
series Romanian Journal of Oral Rehabilitation
spelling doaj.art-a928ee3a5c75410e83a495277b9fe48d2022-12-21T18:56:06ZengRomanian Society of Oral RehabilitationRomanian Journal of Oral Rehabilitation2066-70002066-70002017-07-01928993BIOMECHANICAL ASPECTS OF IMPRESSIONS IN PARTIALLY EDENTULOUSCibela Caras0Doriana Agop1Norina Consuela Forna2Department of Implantology, Removable Dentures, Technology Faculty of Dental Medecine,”Grigore T.Popa” University of Medecine and PharmacyDepartment of Implantology, Removable Dentures, Technology Faculty of Dental Medecine,”Grigore T.Popa” University of Medecine and PharmacyDepartment of Implantology, Removable Dentures, Technology Faculty of Dental Medecine,”Grigore T.Popa” University of Medecine and PharmacyAim of the study The aim of this study is to identify a crucial stage of treatment or functional fingerprint, quantify the factors underlying the choice of method of fingerprinting, according to the particularity of the prosthetic field, to ensure an optimal management of the removable prosthetic therapy. Material and methods Within the partially stretched edentulous several methods of functional fingerprinting were described, different from total edentulous, usually using certain criteria: edentulous class I, II, III, IV, Kennedy, V, VI, Kennedy Applegate, supporting prosthetic field muco-bone with high or low resilience; edentulous ridge with sharp or stationary resorption; type of prosthesis, type of occlusion – no contacts of dental decay, the presence of unstable dental decay , presence of a stabile dental impression .Results Particularities of the prosthetic field clinic-biological related to indices that characterize the odonto periodontal status and the muco-bone, are those that dictate the type of material chosen, the footprint viscosity imprint material or chosen technique. Conclusions : Functional fingerprinting is a very important clinical stage with a profound impact in producing the final prosthetichttp://www.rjor.ro/biomechanical-aspects-of-impressions-in-partially-edentulous/?lang=robiomechanical behaviouredentulousfunctional impressions
spellingShingle Cibela Caras
Doriana Agop
Norina Consuela Forna
BIOMECHANICAL ASPECTS OF IMPRESSIONS IN PARTIALLY EDENTULOUS
Romanian Journal of Oral Rehabilitation
biomechanical behaviour
edentulous
functional impressions
title BIOMECHANICAL ASPECTS OF IMPRESSIONS IN PARTIALLY EDENTULOUS
title_full BIOMECHANICAL ASPECTS OF IMPRESSIONS IN PARTIALLY EDENTULOUS
title_fullStr BIOMECHANICAL ASPECTS OF IMPRESSIONS IN PARTIALLY EDENTULOUS
title_full_unstemmed BIOMECHANICAL ASPECTS OF IMPRESSIONS IN PARTIALLY EDENTULOUS
title_short BIOMECHANICAL ASPECTS OF IMPRESSIONS IN PARTIALLY EDENTULOUS
title_sort biomechanical aspects of impressions in partially edentulous
topic biomechanical behaviour
edentulous
functional impressions
url http://www.rjor.ro/biomechanical-aspects-of-impressions-in-partially-edentulous/?lang=ro
work_keys_str_mv AT cibelacaras biomechanicalaspectsofimpressionsinpartiallyedentulous
AT dorianaagop biomechanicalaspectsofimpressionsinpartiallyedentulous
AT norinaconsuelaforna biomechanicalaspectsofimpressionsinpartiallyedentulous