Dynamics of harmful factors in inclined road tunnels according to the results of numerical modeling of up to 50 MW fires in terms of natural ventilation

The present paper explores the change of the harmful factors by means of full-scale numerical models. In the numerical models, the tunnel length is 400 m; the slope gradient varies within 0-9%, with a 2% step; and the heat release rate is within 5-50 MW. The outdoor air temperature on the models was...

Full description

Bibliographic Details
Main Authors: Lanchava Omar, Ilias Nicolae, Radu Sorin Mihai, Nozadze Giorgi, Javakhishvili Giorgi
Format: Article
Language:English
Published: EDP Sciences 2024-01-01
Series:MATEC Web of Conferences
Online Access:https://www.matec-conferences.org/articles/matecconf/pdf/2024/01/matecconf_sesam2023_00056.pdf