Evaluation of contrast sensitivity in visually impaired individuals using K-CS test. A novel smartphone-based contrast sensitivity test-Design and validation.

<h4>Background</h4>To describe the development and investigate the accuracy of a novel smartphone-based Contrast Sensitivity (CS) application, the K-CS test.<h4>Methods</h4>A total of 67 visually impaired and 50 normal participants were examined monocularly using the novel di...

Full description

Bibliographic Details
Main Authors: Vasileios Karampatakis, Eleni P Papadopoulou, Stavroula Almpanidou, Leonidas Karamitopoulos, Diamantis Almaliotis
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2024-01-01
Series:PLoS ONE
Online Access:https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0288512&type=printable
_version_ 1797304777776824320
author Vasileios Karampatakis
Eleni P Papadopoulou
Stavroula Almpanidou
Leonidas Karamitopoulos
Diamantis Almaliotis
author_facet Vasileios Karampatakis
Eleni P Papadopoulou
Stavroula Almpanidou
Leonidas Karamitopoulos
Diamantis Almaliotis
author_sort Vasileios Karampatakis
collection DOAJ
description <h4>Background</h4>To describe the development and investigate the accuracy of a novel smartphone-based Contrast Sensitivity (CS) application, the K-CS test.<h4>Methods</h4>A total of 67 visually impaired and 50 normal participants were examined monocularly using the novel digital K-CS test and the Pelli-Robson (PR) chart. The K-CS test examines letter contrast sensitivity in logarithmic units, using eight levels of contrast from logCS = ~0,1 to logCS = ~2,1 at two spatial frequencies of 1.5 and 3 cycles per degree (cpd). The K-CS test was compared to the gold standard, PR test and intra-session test repeatability was also examined.<h4>Results</h4>The K-CS test in normally sighted was found to agree well with the PR, providing comparable mean scores in logCS (±SD) (K-CS = 1.908 ± 0.06 versus PR = 1.93 ± 0.05) at 1.5 cpd and mean (± SD) logCS at 3 cpd (K-CS = 1.83 ± 0.13 versus PR = 1.86 ± 0.07). The mean best corrected visual acuity of visually impaired participants was 0.67 LogMAR (SD = 0.21) and the K-CS was also found to agree well with the Pelli-Robson in this group, with an equivalent mean (±SD) logCS at 1.5 cpd: (K-CS = 1.19 ± 0.27, PR = 1.15 ± 0.31), 3 cpd: K-CS = 1.01 ± 0.33, PR = 0.94 ± 0.34. Regarding the intra-session test repeatability, both the K-CS test and the PR test showed good repeatability in terms of the 95% limits of agreement (LoA): K-CS = ±0.112 at 1.5 cpd and ±0.133 at 3 cpd, PR = ±0.143 at 1.5 cpd and ±0.183 in 3 cpd in visually impaired individuals.<h4>Conclusion</h4>The K-CS test provides a quick assessment of the CS both in normally sighted and visually impaired individuals. The K-CS could serve as an alternative tool to assess contrast sensitivity function using a smartphone and provides results that agree well with the commonly used PR test.
first_indexed 2024-03-08T00:15:23Z
format Article
id doaj.art-a9e7a701f2404b29967be72544d99c31
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-03-08T00:15:23Z
publishDate 2024-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-a9e7a701f2404b29967be72544d99c312024-02-17T05:32:54ZengPublic Library of Science (PLoS)PLoS ONE1932-62032024-01-01192e028851210.1371/journal.pone.0288512Evaluation of contrast sensitivity in visually impaired individuals using K-CS test. A novel smartphone-based contrast sensitivity test-Design and validation.Vasileios KarampatakisEleni P PapadopoulouStavroula AlmpanidouLeonidas KaramitopoulosDiamantis Almaliotis<h4>Background</h4>To describe the development and investigate the accuracy of a novel smartphone-based Contrast Sensitivity (CS) application, the K-CS test.<h4>Methods</h4>A total of 67 visually impaired and 50 normal participants were examined monocularly using the novel digital K-CS test and the Pelli-Robson (PR) chart. The K-CS test examines letter contrast sensitivity in logarithmic units, using eight levels of contrast from logCS = ~0,1 to logCS = ~2,1 at two spatial frequencies of 1.5 and 3 cycles per degree (cpd). The K-CS test was compared to the gold standard, PR test and intra-session test repeatability was also examined.<h4>Results</h4>The K-CS test in normally sighted was found to agree well with the PR, providing comparable mean scores in logCS (±SD) (K-CS = 1.908 ± 0.06 versus PR = 1.93 ± 0.05) at 1.5 cpd and mean (± SD) logCS at 3 cpd (K-CS = 1.83 ± 0.13 versus PR = 1.86 ± 0.07). The mean best corrected visual acuity of visually impaired participants was 0.67 LogMAR (SD = 0.21) and the K-CS was also found to agree well with the Pelli-Robson in this group, with an equivalent mean (±SD) logCS at 1.5 cpd: (K-CS = 1.19 ± 0.27, PR = 1.15 ± 0.31), 3 cpd: K-CS = 1.01 ± 0.33, PR = 0.94 ± 0.34. Regarding the intra-session test repeatability, both the K-CS test and the PR test showed good repeatability in terms of the 95% limits of agreement (LoA): K-CS = ±0.112 at 1.5 cpd and ±0.133 at 3 cpd, PR = ±0.143 at 1.5 cpd and ±0.183 in 3 cpd in visually impaired individuals.<h4>Conclusion</h4>The K-CS test provides a quick assessment of the CS both in normally sighted and visually impaired individuals. The K-CS could serve as an alternative tool to assess contrast sensitivity function using a smartphone and provides results that agree well with the commonly used PR test.https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0288512&type=printable
spellingShingle Vasileios Karampatakis
Eleni P Papadopoulou
Stavroula Almpanidou
Leonidas Karamitopoulos
Diamantis Almaliotis
Evaluation of contrast sensitivity in visually impaired individuals using K-CS test. A novel smartphone-based contrast sensitivity test-Design and validation.
PLoS ONE
title Evaluation of contrast sensitivity in visually impaired individuals using K-CS test. A novel smartphone-based contrast sensitivity test-Design and validation.
title_full Evaluation of contrast sensitivity in visually impaired individuals using K-CS test. A novel smartphone-based contrast sensitivity test-Design and validation.
title_fullStr Evaluation of contrast sensitivity in visually impaired individuals using K-CS test. A novel smartphone-based contrast sensitivity test-Design and validation.
title_full_unstemmed Evaluation of contrast sensitivity in visually impaired individuals using K-CS test. A novel smartphone-based contrast sensitivity test-Design and validation.
title_short Evaluation of contrast sensitivity in visually impaired individuals using K-CS test. A novel smartphone-based contrast sensitivity test-Design and validation.
title_sort evaluation of contrast sensitivity in visually impaired individuals using k cs test a novel smartphone based contrast sensitivity test design and validation
url https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0288512&type=printable
work_keys_str_mv AT vasileioskarampatakis evaluationofcontrastsensitivityinvisuallyimpairedindividualsusingkcstestanovelsmartphonebasedcontrastsensitivitytestdesignandvalidation
AT elenippapadopoulou evaluationofcontrastsensitivityinvisuallyimpairedindividualsusingkcstestanovelsmartphonebasedcontrastsensitivitytestdesignandvalidation
AT stavroulaalmpanidou evaluationofcontrastsensitivityinvisuallyimpairedindividualsusingkcstestanovelsmartphonebasedcontrastsensitivitytestdesignandvalidation
AT leonidaskaramitopoulos evaluationofcontrastsensitivityinvisuallyimpairedindividualsusingkcstestanovelsmartphonebasedcontrastsensitivitytestdesignandvalidation
AT diamantisalmaliotis evaluationofcontrastsensitivityinvisuallyimpairedindividualsusingkcstestanovelsmartphonebasedcontrastsensitivitytestdesignandvalidation