Difference in implant design affects midflexion rotational laxity in cruciate‐retaining total knee arthroplasty: a computer navigation study

Abstract Purpose This study aimed to compare midflexion rotational laxity between two different design concept models of cruciate‐retaining total knee arthroplasty: symmetrical surface design of neutral joint line obliquity and asymmetrical surface design of varus joint line obliquity. Methods Sixty...

Full description

Bibliographic Details
Main Authors: Takashi Tsuda, Kazunori Hino, Tatsuhiko Kutsuna, Kunihiko Watamori, Tomofumi Kinoshita, Masaki Takao
Format: Article
Language:English
Published: Wiley 2023-01-01
Series:Journal of Experimental Orthopaedics
Subjects:
Online Access:https://doi.org/10.1186/s40634-023-00652-6
_version_ 1827324271699951616
author Takashi Tsuda
Kazunori Hino
Tatsuhiko Kutsuna
Kunihiko Watamori
Tomofumi Kinoshita
Masaki Takao
author_facet Takashi Tsuda
Kazunori Hino
Tatsuhiko Kutsuna
Kunihiko Watamori
Tomofumi Kinoshita
Masaki Takao
author_sort Takashi Tsuda
collection DOAJ
description Abstract Purpose This study aimed to compare midflexion rotational laxity between two different design concept models of cruciate‐retaining total knee arthroplasty: symmetrical surface design of neutral joint line obliquity and asymmetrical surface design of varus joint line obliquity. Methods Sixty‐three knees that underwent cruciate‐retaining total knee arthroplasty were evaluated. Manual maximum passive rotational stress without acceleration was applied to the knees under navigation monitoring. Pre‐operative and post‐operative internal and external rotational angles were measured at 30°, 45°, 60°, and 90° knee flexion. Results The post‐operative internal rotational laxity was significantly increased compared with pre‐operative levels at 30°, 45°, 60°, and 90° flexion among all subjects (mean 9.7° vs 11.1°, 10.6° vs 11.6°, 11.2° vs 12.9°, and 13.2° vs 14.9°; p = 0.01, 0.04, 0.001, and 0.008, respectively). The post‐operative external rotational laxity was significantly decreased compared to pre‐operative levels at 30°, 45°, 60°, and 90° flexion among all subjects (mean 10.8° vs 6.8°, 12.5° vs 9.4°, 12.8° vs 10.0°, and 11.3° vs 9.5°; p < 0.0001, < 0.0001, < 0.0001, and 0.0008, respectively). The post‐operative total rotational laxity significantly decreased, compared with pre‐operative levels, at 30° and 45° flexion among all subjects (mean 20.4° vs 17.9°, and 23.1° vs 21.1°; p = 0.002 and 0.04, respectively). The post‐operative total rotational laxity was significantly smaller in asymmetrically designed total knee arthroplasty than in symmetrically designed total knee arthroplasty at 30°, 45°, and 60° flexion (mean 19.3° vs 15.8°, 22.8° vs 18.7°, and 24.4° vs 20.8°; p = 0.03, 0.03, and 0.02, respectively), whereas no significant difference was observed at 90° flexion. Conclusion Compared to symmetrical surface design, asymmetrical surface design resulted in lower rotational laxity at the midflexion range in cruciate‐retaining total knee arthroplasty. Level of evidence III.
first_indexed 2024-03-08T04:57:41Z
format Article
id doaj.art-aa4595920c1c44ab8c8d5d87626b471d
institution Directory Open Access Journal
issn 2197-1153
language English
last_indexed 2024-04-25T02:09:52Z
publishDate 2023-01-01
publisher Wiley
record_format Article
series Journal of Experimental Orthopaedics
spelling doaj.art-aa4595920c1c44ab8c8d5d87626b471d2024-03-07T12:46:42ZengWileyJournal of Experimental Orthopaedics2197-11532023-01-01101n/an/a10.1186/s40634-023-00652-6Difference in implant design affects midflexion rotational laxity in cruciate‐retaining total knee arthroplasty: a computer navigation studyTakashi Tsuda0Kazunori Hino1Tatsuhiko Kutsuna2Kunihiko Watamori3Tomofumi Kinoshita4Masaki Takao5Department of Bone and Joint SurgeryEhime UniversityGraduate School of MedicineShitsukawa791‐0295Toon CityEhimeJapanDepartment of Joint ReconstructionEhime UniversityGraduate School of MedicineShitsukawa791‐0295Toon CityEhimeJapanDepartment of Bone and Joint SurgeryEhime UniversityGraduate School of MedicineShitsukawa791‐0295Toon CityEhimeJapanDepartment of Joint ReconstructionEhime UniversityGraduate School of MedicineShitsukawa791‐0295Toon CityEhimeJapanDepartment of Bone and Joint SurgeryEhime UniversityGraduate School of MedicineShitsukawa791‐0295Toon CityEhimeJapanDepartment of Bone and Joint SurgeryEhime UniversityGraduate School of MedicineShitsukawa791‐0295Toon CityEhimeJapanAbstract Purpose This study aimed to compare midflexion rotational laxity between two different design concept models of cruciate‐retaining total knee arthroplasty: symmetrical surface design of neutral joint line obliquity and asymmetrical surface design of varus joint line obliquity. Methods Sixty‐three knees that underwent cruciate‐retaining total knee arthroplasty were evaluated. Manual maximum passive rotational stress without acceleration was applied to the knees under navigation monitoring. Pre‐operative and post‐operative internal and external rotational angles were measured at 30°, 45°, 60°, and 90° knee flexion. Results The post‐operative internal rotational laxity was significantly increased compared with pre‐operative levels at 30°, 45°, 60°, and 90° flexion among all subjects (mean 9.7° vs 11.1°, 10.6° vs 11.6°, 11.2° vs 12.9°, and 13.2° vs 14.9°; p = 0.01, 0.04, 0.001, and 0.008, respectively). The post‐operative external rotational laxity was significantly decreased compared to pre‐operative levels at 30°, 45°, 60°, and 90° flexion among all subjects (mean 10.8° vs 6.8°, 12.5° vs 9.4°, 12.8° vs 10.0°, and 11.3° vs 9.5°; p < 0.0001, < 0.0001, < 0.0001, and 0.0008, respectively). The post‐operative total rotational laxity significantly decreased, compared with pre‐operative levels, at 30° and 45° flexion among all subjects (mean 20.4° vs 17.9°, and 23.1° vs 21.1°; p = 0.002 and 0.04, respectively). The post‐operative total rotational laxity was significantly smaller in asymmetrically designed total knee arthroplasty than in symmetrically designed total knee arthroplasty at 30°, 45°, and 60° flexion (mean 19.3° vs 15.8°, 22.8° vs 18.7°, and 24.4° vs 20.8°; p = 0.03, 0.03, and 0.02, respectively), whereas no significant difference was observed at 90° flexion. Conclusion Compared to symmetrical surface design, asymmetrical surface design resulted in lower rotational laxity at the midflexion range in cruciate‐retaining total knee arthroplasty. Level of evidence III.https://doi.org/10.1186/s40634-023-00652-6Total knee arthroplastyDesign of implantsRotational laxityMidflexion laxityNavigation systemCruciate‐retaining
spellingShingle Takashi Tsuda
Kazunori Hino
Tatsuhiko Kutsuna
Kunihiko Watamori
Tomofumi Kinoshita
Masaki Takao
Difference in implant design affects midflexion rotational laxity in cruciate‐retaining total knee arthroplasty: a computer navigation study
Journal of Experimental Orthopaedics
Total knee arthroplasty
Design of implants
Rotational laxity
Midflexion laxity
Navigation system
Cruciate‐retaining
title Difference in implant design affects midflexion rotational laxity in cruciate‐retaining total knee arthroplasty: a computer navigation study
title_full Difference in implant design affects midflexion rotational laxity in cruciate‐retaining total knee arthroplasty: a computer navigation study
title_fullStr Difference in implant design affects midflexion rotational laxity in cruciate‐retaining total knee arthroplasty: a computer navigation study
title_full_unstemmed Difference in implant design affects midflexion rotational laxity in cruciate‐retaining total knee arthroplasty: a computer navigation study
title_short Difference in implant design affects midflexion rotational laxity in cruciate‐retaining total knee arthroplasty: a computer navigation study
title_sort difference in implant design affects midflexion rotational laxity in cruciate retaining total knee arthroplasty a computer navigation study
topic Total knee arthroplasty
Design of implants
Rotational laxity
Midflexion laxity
Navigation system
Cruciate‐retaining
url https://doi.org/10.1186/s40634-023-00652-6
work_keys_str_mv AT takashitsuda differenceinimplantdesignaffectsmidflexionrotationallaxityincruciateretainingtotalkneearthroplastyacomputernavigationstudy
AT kazunorihino differenceinimplantdesignaffectsmidflexionrotationallaxityincruciateretainingtotalkneearthroplastyacomputernavigationstudy
AT tatsuhikokutsuna differenceinimplantdesignaffectsmidflexionrotationallaxityincruciateretainingtotalkneearthroplastyacomputernavigationstudy
AT kunihikowatamori differenceinimplantdesignaffectsmidflexionrotationallaxityincruciateretainingtotalkneearthroplastyacomputernavigationstudy
AT tomofumikinoshita differenceinimplantdesignaffectsmidflexionrotationallaxityincruciateretainingtotalkneearthroplastyacomputernavigationstudy
AT masakitakao differenceinimplantdesignaffectsmidflexionrotationallaxityincruciateretainingtotalkneearthroplastyacomputernavigationstudy