Improved Methodology for Power Transformer Loss Evaluation: Algorithm Refinement and Resonance Risk Analysis

The decline in power quality within electrical networks is adversely impacting the energy efficiency and safety of transmission elements. The growing prevalence of power electronics has elevated harmonic levels in the grid to an extent where their significance cannot be overlooked. Additionally, the...

Full description

Bibliographic Details
Main Authors: Mantas Plienis, Tomas Deveikis, Audrius Jonaitis, Saulius Gudžius, Inga Konstantinavičiūtė, Donata Putnaitė
Format: Article
Language:English
Published: MDPI AG 2023-11-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/16/23/7837
_version_ 1797400199158562816
author Mantas Plienis
Tomas Deveikis
Audrius Jonaitis
Saulius Gudžius
Inga Konstantinavičiūtė
Donata Putnaitė
author_facet Mantas Plienis
Tomas Deveikis
Audrius Jonaitis
Saulius Gudžius
Inga Konstantinavičiūtė
Donata Putnaitė
author_sort Mantas Plienis
collection DOAJ
description The decline in power quality within electrical networks is adversely impacting the energy efficiency and safety of transmission elements. The growing prevalence of power electronics has elevated harmonic levels in the grid to an extent where their significance cannot be overlooked. Additionally, the increasing integration of renewable energy sources introduces heightened fluctuations, rendering the prediction and simulation of working modes more challenging. This paper presents an improved algorithm for calculating power transformer losses attributed to harmonics, with a comprehensive validation against simulation results obtained from the Power Factory application and real-world measurements. The advantages of the algorithm are that all evaluations are performed in real-time based on single-point measurements, and the algorithm was easy to implement in a Programmable Logic Controller (PLC). This allows us to receive the exchange of information to energy monitoring systems (EMSs) or with Power factor Correction Units (PFCUs) and control it. To facilitate a more intuitive understanding and visualization of potential hazardous scenarios related to resonance, an extra Dijkstra algorithm was implemented. This augmentation enables the identification of conditions, wherein certain branches exhibit lower resistance than the grid connection point, indicating a heightened risk of resonance and the presence of highly distorted currents. Recognizing that monitoring alone does not inherently contribute to increased energy efficiency, the algorithm was further expanded to assess transformer losses across a spectrum of Power Factory Correction Units power levels. Additionally, a command from a PLC to a PFCU can now be initiated to change the capacitance level and near-resonance working mode. These advancements collectively contribute to a more robust and versatile methodology for evaluating power transformer losses, offering enhanced accuracy and the ability to visualize potentially critical resonance scenarios.
first_indexed 2024-03-09T01:52:07Z
format Article
id doaj.art-aa566f90563142ebb4b2c3e8786a8fef
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-09T01:52:07Z
publishDate 2023-11-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-aa566f90563142ebb4b2c3e8786a8fef2023-12-08T15:14:59ZengMDPI AGEnergies1996-10732023-11-011623783710.3390/en16237837Improved Methodology for Power Transformer Loss Evaluation: Algorithm Refinement and Resonance Risk AnalysisMantas Plienis0Tomas Deveikis1Audrius Jonaitis2Saulius Gudžius3Inga Konstantinavičiūtė4Donata Putnaitė5Department of Electric Power Systems, Kaunas University of Technology, Studentu Str. 48, LT-51367 Kaunas, LithuaniaDepartment of Electric Power Systems, Kaunas University of Technology, Studentu Str. 48, LT-51367 Kaunas, LithuaniaDepartment of Electric Power Systems, Kaunas University of Technology, Studentu Str. 48, LT-51367 Kaunas, LithuaniaDepartment of Electric Power Systems, Kaunas University of Technology, Studentu Str. 48, LT-51367 Kaunas, LithuaniaDepartment of Electric Power Systems, Kaunas University of Technology, Studentu Str. 48, LT-51367 Kaunas, LithuaniaDepartment of Electric Power Systems, Kaunas University of Technology, Studentu Str. 48, LT-51367 Kaunas, LithuaniaThe decline in power quality within electrical networks is adversely impacting the energy efficiency and safety of transmission elements. The growing prevalence of power electronics has elevated harmonic levels in the grid to an extent where their significance cannot be overlooked. Additionally, the increasing integration of renewable energy sources introduces heightened fluctuations, rendering the prediction and simulation of working modes more challenging. This paper presents an improved algorithm for calculating power transformer losses attributed to harmonics, with a comprehensive validation against simulation results obtained from the Power Factory application and real-world measurements. The advantages of the algorithm are that all evaluations are performed in real-time based on single-point measurements, and the algorithm was easy to implement in a Programmable Logic Controller (PLC). This allows us to receive the exchange of information to energy monitoring systems (EMSs) or with Power factor Correction Units (PFCUs) and control it. To facilitate a more intuitive understanding and visualization of potential hazardous scenarios related to resonance, an extra Dijkstra algorithm was implemented. This augmentation enables the identification of conditions, wherein certain branches exhibit lower resistance than the grid connection point, indicating a heightened risk of resonance and the presence of highly distorted currents. Recognizing that monitoring alone does not inherently contribute to increased energy efficiency, the algorithm was further expanded to assess transformer losses across a spectrum of Power Factory Correction Units power levels. Additionally, a command from a PLC to a PFCU can now be initiated to change the capacitance level and near-resonance working mode. These advancements collectively contribute to a more robust and versatile methodology for evaluating power transformer losses, offering enhanced accuracy and the ability to visualize potentially critical resonance scenarios.https://www.mdpi.com/1996-1073/16/23/7837power transformer lossesenergy efficiencyresonance hazardharmonics
spellingShingle Mantas Plienis
Tomas Deveikis
Audrius Jonaitis
Saulius Gudžius
Inga Konstantinavičiūtė
Donata Putnaitė
Improved Methodology for Power Transformer Loss Evaluation: Algorithm Refinement and Resonance Risk Analysis
Energies
power transformer losses
energy efficiency
resonance hazard
harmonics
title Improved Methodology for Power Transformer Loss Evaluation: Algorithm Refinement and Resonance Risk Analysis
title_full Improved Methodology for Power Transformer Loss Evaluation: Algorithm Refinement and Resonance Risk Analysis
title_fullStr Improved Methodology for Power Transformer Loss Evaluation: Algorithm Refinement and Resonance Risk Analysis
title_full_unstemmed Improved Methodology for Power Transformer Loss Evaluation: Algorithm Refinement and Resonance Risk Analysis
title_short Improved Methodology for Power Transformer Loss Evaluation: Algorithm Refinement and Resonance Risk Analysis
title_sort improved methodology for power transformer loss evaluation algorithm refinement and resonance risk analysis
topic power transformer losses
energy efficiency
resonance hazard
harmonics
url https://www.mdpi.com/1996-1073/16/23/7837
work_keys_str_mv AT mantasplienis improvedmethodologyforpowertransformerlossevaluationalgorithmrefinementandresonanceriskanalysis
AT tomasdeveikis improvedmethodologyforpowertransformerlossevaluationalgorithmrefinementandresonanceriskanalysis
AT audriusjonaitis improvedmethodologyforpowertransformerlossevaluationalgorithmrefinementandresonanceriskanalysis
AT sauliusgudzius improvedmethodologyforpowertransformerlossevaluationalgorithmrefinementandresonanceriskanalysis
AT ingakonstantinaviciute improvedmethodologyforpowertransformerlossevaluationalgorithmrefinementandresonanceriskanalysis
AT donataputnaite improvedmethodologyforpowertransformerlossevaluationalgorithmrefinementandresonanceriskanalysis