Theoretical estimate of relative depth-doses for the asymmetric and spherical 106Ru/106Rh COC-type plaque used in radiotherapy
In this work we present results of relative dose rate along central and lateral axis of the 106Ru/106Rh COC model plaque used for the treatment of tumors close to the optical nerve. The calculations were based on the beta-point dose function and are compared with an available data obtained by means...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)
2020-03-01
|
Series: | Brazilian Journal of Radiation Sciences |
Subjects: | |
Online Access: | https://bjrs.org.br/revista/index.php/REVISTA/article/view/1125 |
_version_ | 1811234597686476800 |
---|---|
author | Eduardo De Paiva |
author_facet | Eduardo De Paiva |
author_sort | Eduardo De Paiva |
collection | DOAJ |
description | In this work we present results of relative dose rate along central and lateral axis of the 106Ru/106Rh COC model plaque used for the treatment of tumors close to the optical nerve. The calculations were based on the beta-point dose function and are compared with an available data obtained by means of Monte Carlo simulations. Even with the limitations of the method, it was capable to reproduce the general trend of the dose rates around this kind of plaque and a maximum difference of -18% with MC was obtained. Despite the limitations of the method, the results may be used as a guide to future experimental and theoretical studies on this applicator, since there is a lack of available data in literature. |
first_indexed | 2024-04-12T11:38:53Z |
format | Article |
id | doaj.art-aa7348ebc64d44448dc12624fbeceb7e |
institution | Directory Open Access Journal |
issn | 2319-0612 |
language | English |
last_indexed | 2024-04-12T11:38:53Z |
publishDate | 2020-03-01 |
publisher | Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR) |
record_format | Article |
series | Brazilian Journal of Radiation Sciences |
spelling | doaj.art-aa7348ebc64d44448dc12624fbeceb7e2022-12-22T03:34:44ZengBrazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)Brazilian Journal of Radiation Sciences2319-06122020-03-018110.15392/bjrs.v8i1.1125Theoretical estimate of relative depth-doses for the asymmetric and spherical 106Ru/106Rh COC-type plaque used in radiotherapyEduardo De Paiva0Divisão de Física Médica, Instituto de Radioproteção e Dosimetria - IRD/CNENIn this work we present results of relative dose rate along central and lateral axis of the 106Ru/106Rh COC model plaque used for the treatment of tumors close to the optical nerve. The calculations were based on the beta-point dose function and are compared with an available data obtained by means of Monte Carlo simulations. Even with the limitations of the method, it was capable to reproduce the general trend of the dose rates around this kind of plaque and a maximum difference of -18% with MC was obtained. Despite the limitations of the method, the results may be used as a guide to future experimental and theoretical studies on this applicator, since there is a lack of available data in literature.https://bjrs.org.br/revista/index.php/REVISTA/article/view/1125beta particlesasymmetric beta ophthalmic applicatorsrelative depth-dose106Ru/106Rh |
spellingShingle | Eduardo De Paiva Theoretical estimate of relative depth-doses for the asymmetric and spherical 106Ru/106Rh COC-type plaque used in radiotherapy Brazilian Journal of Radiation Sciences beta particles asymmetric beta ophthalmic applicators relative depth-dose 106Ru/106Rh |
title | Theoretical estimate of relative depth-doses for the asymmetric and spherical 106Ru/106Rh COC-type plaque used in radiotherapy |
title_full | Theoretical estimate of relative depth-doses for the asymmetric and spherical 106Ru/106Rh COC-type plaque used in radiotherapy |
title_fullStr | Theoretical estimate of relative depth-doses for the asymmetric and spherical 106Ru/106Rh COC-type plaque used in radiotherapy |
title_full_unstemmed | Theoretical estimate of relative depth-doses for the asymmetric and spherical 106Ru/106Rh COC-type plaque used in radiotherapy |
title_short | Theoretical estimate of relative depth-doses for the asymmetric and spherical 106Ru/106Rh COC-type plaque used in radiotherapy |
title_sort | theoretical estimate of relative depth doses for the asymmetric and spherical 106ru 106rh coc type plaque used in radiotherapy |
topic | beta particles asymmetric beta ophthalmic applicators relative depth-dose 106Ru/106Rh |
url | https://bjrs.org.br/revista/index.php/REVISTA/article/view/1125 |
work_keys_str_mv | AT eduardodepaiva theoreticalestimateofrelativedepthdosesfortheasymmetricandspherical106ru106rhcoctypeplaqueusedinradiotherapy |