A Study on the Mortality and Complication Rates Following Percutaneously Adjustable Pulmonary Artery Banding

Introduction: Pulmonary artery (PA) banding is a procedure associated with high morbidityand mortality rates. It however can effectively palliate several forms of congenital heart lesionswith increased pulmonary flow. Occasionally, to obtain an optimal degree of banding following operation, readjust...

Full description

Bibliographic Details
Main Authors: Changizi Ali, Yaghoubi Alireza, Azarasa Mitra, Ghaffari Shamsi, Montazerghaem Hossein
Format: Article
Language:English
Published: Tabriz University of Medical Sciences 2014-12-01
Series:Journal of Cardiovascular and Thoracic Research
Subjects:
Online Access:http://journals.tbzmed.ac.ir/JCVTR/PDF/JCVTR-6-253.pdf
Description
Summary:Introduction: Pulmonary artery (PA) banding is a procedure associated with high morbidityand mortality rates. It however can effectively palliate several forms of congenital heart lesionswith increased pulmonary flow. Occasionally, to obtain an optimal degree of banding following operation, readjustment of the band is inevitable. We describe the technique of adjustable PA banding to prevent this problem.Methods: From June 2007 to 2008, 21 patients with congenital cardiac abnormalities including Single ventricle (1), transposition of great arteries (TGA) (4) and ventricular septal defect (VSD)(16) were operated via percutaneously adjustable PA banding in Madani Hospital (Tabriz, Iran).Results: The mean age and the mean weight of the patients were 12±.8 months and 61±.7 kg respectively. Seventeen (81%) patients survived the operation. Cause of death was heart failurein 2 (9.5%) patients, and arrhythmia in 2 (9.5%) patients. Later, patients were followed up for 6 months. Satisfactory band gradient was achieved between 48 and 240 hours. Mean PA gradient before and 1 and 6 months after adjusting was (55.3±7.1 mmHg), (54.7±5.1 mmHg),and (53.2±5.4 mmHg) respectively. In the follow up period, there were 2 deaths, one causedby aspiration pneumonia and one caused by poor mixing. Postoperative complications wereobserved in 28.5% of the cases including cardiac (10%), pulmonary (pneumothorax, pneumonia)(10%) and infectious complications (9%).Conclusion: The technique of percutaneously adjustable PA banding is simple and inexpensiveand allows easy band adjustments without the need for multiple reoperations. Moreover, our assessment reveals that created gradient is constant and did not decrease with time.
ISSN:2008-5117