Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid Codes

A new single-phase transformerless grid-connected PV inverter is presented in this paper. Investigations in transformerless grid-connected PV inverters indicate the existence of the leakage current is directly related to the variable common-mode voltage (CMV), which is presented in detail. On the ot...

Full description

Bibliographic Details
Main Authors: F. Mohammadi, J. Milimonfared, H. Rastegar, M. Farhadi-Kangarlu
Format: Article
Language:English
Published: University of Mohaghegh Ardabili 2021-04-01
Series:Journal of Operation and Automation in Power Engineering
Subjects:
Online Access:http://joape.uma.ac.ir/article_913_ed10c7ba48cb84cee9b9cd6faa330229.pdf
_version_ 1818594851730489344
author F. Mohammadi
J. Milimonfared
H. Rastegar
M. Farhadi-Kangarlu
author_facet F. Mohammadi
J. Milimonfared
H. Rastegar
M. Farhadi-Kangarlu
author_sort F. Mohammadi
collection DOAJ
description A new single-phase transformerless grid-connected PV inverter is presented in this paper. Investigations in transformerless grid-connected PV inverters indicate the existence of the leakage current is directly related to the variable common-mode voltage (CMV), which is presented in detail. On the other hand, in recent years it has become mandatory for the transformerless grid-connected PV inverters to satisfy new grid-codes such as low-voltage ride-through (LVRT) capability via injecting reactive power during grid faults. Therefore, in this paper, the design of the proposed topology is based on retaining the constant CMV to suppress the leakage current and also to provide reactive power injection capability during grid faults. The control strategies for injecting reactive power in the LVRT condition are also examined. To validate the presented theoretical concepts, the performance and dynamic response of the proposed transformerless PV inverter are investigated by MATLAB/Simulink and the simulation results are presented and discussed.
first_indexed 2024-12-16T11:06:42Z
format Article
id doaj.art-ab6b13fd8f5e44d59584b42bd6c81a68
institution Directory Open Access Journal
issn 2322-4576
language English
last_indexed 2024-12-16T11:06:42Z
publishDate 2021-04-01
publisher University of Mohaghegh Ardabili
record_format Article
series Journal of Operation and Automation in Power Engineering
spelling doaj.art-ab6b13fd8f5e44d59584b42bd6c81a682022-12-21T22:33:51ZengUniversity of Mohaghegh ArdabiliJournal of Operation and Automation in Power Engineering2322-45762021-04-0191495910.22098/joape.2021.6660.1494913Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid CodesF. Mohammadi0J. Milimonfared1H. Rastegar2M. Farhadi-Kangarlu3Department of Electrical Engineering, Amirkabir University of Technology, Tehran, Iran‎Department of Electrical Engineering, Amirkabir University of Technology, Tehran, Iran‎Department of Electrical Engineering, Amirkabir University of Technology, Tehran, Iran‎Faculty of Electrical and Computer Engineering, Urmia University, Urmia, Iran‎‏.‏A new single-phase transformerless grid-connected PV inverter is presented in this paper. Investigations in transformerless grid-connected PV inverters indicate the existence of the leakage current is directly related to the variable common-mode voltage (CMV), which is presented in detail. On the other hand, in recent years it has become mandatory for the transformerless grid-connected PV inverters to satisfy new grid-codes such as low-voltage ride-through (LVRT) capability via injecting reactive power during grid faults. Therefore, in this paper, the design of the proposed topology is based on retaining the constant CMV to suppress the leakage current and also to provide reactive power injection capability during grid faults. The control strategies for injecting reactive power in the LVRT condition are also examined. To validate the presented theoretical concepts, the performance and dynamic response of the proposed transformerless PV inverter are investigated by MATLAB/Simulink and the simulation results are presented and discussed.http://joape.uma.ac.ir/article_913_ed10c7ba48cb84cee9b9cd6faa330229.pdftransformerless grid-connected pv inverterleakage currentcommon-mode voltagelvrt
spellingShingle F. Mohammadi
J. Milimonfared
H. Rastegar
M. Farhadi-Kangarlu
Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid Codes
Journal of Operation and Automation in Power Engineering
transformerless grid-connected pv inverter
leakage current
common-mode voltage
lvrt
title Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid Codes
title_full Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid Codes
title_fullStr Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid Codes
title_full_unstemmed Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid Codes
title_short Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid Codes
title_sort design of a single phase transformerless grid connected pv inverter ‎considering reduced leakage current and lvrt grid codes
topic transformerless grid-connected pv inverter
leakage current
common-mode voltage
lvrt
url http://joape.uma.ac.ir/article_913_ed10c7ba48cb84cee9b9cd6faa330229.pdf
work_keys_str_mv AT fmohammadi designofasinglephasetransformerlessgridconnectedpvinverterconsideringreducedleakagecurrentandlvrtgridcodes
AT jmilimonfared designofasinglephasetransformerlessgridconnectedpvinverterconsideringreducedleakagecurrentandlvrtgridcodes
AT hrastegar designofasinglephasetransformerlessgridconnectedpvinverterconsideringreducedleakagecurrentandlvrtgridcodes
AT mfarhadikangarlu designofasinglephasetransformerlessgridconnectedpvinverterconsideringreducedleakagecurrentandlvrtgridcodes