THE REASONS THAT LEAD TO THE REDUCTION OF THE USE OF NON-REMOVABLE PROSTHESIS DESIGNS

Introduction. Treatment of patients in the clinic of orthopedic dentistry is designed not only to restore function and prevention of complications resulting from dental system damage, as well as the return of the patient to the appropriate aesthetic and cosmetic appearance. Share in the total amount...

Full description

Bibliographic Details
Main Authors: M.J. Nidzelskyy, N.V. Tsvetkova, S.S. Yasnogorskaya
Format: Article
Language:English
Published: Ukrainian Medical Stomatological Academy 2015-03-01
Series:Український стоматологічний альманах
Subjects:
Online Access:https://dental-almanac.org/index.php/journal/article/view/11
_version_ 1818391437381730304
author M.J. Nidzelskyy
N.V. Tsvetkova
S.S. Yasnogorskaya
author_facet M.J. Nidzelskyy
N.V. Tsvetkova
S.S. Yasnogorskaya
author_sort M.J. Nidzelskyy
collection DOAJ
description Introduction. Treatment of patients in the clinic of orthopedic dentistry is designed not only to restore function and prevention of complications resulting from dental system damage, as well as the return of the patient to the appropriate aesthetic and cosmetic appearance. Share in the total amount of all non-removable denture designs, according to different authors, from 70 to 93%. Different figure needs of the population in nonremovable dentures is a relative through nevidtvorennya pictures re prosthetics and clinic visits. In the United States, according to Welton SN, Gardner PM, the average term to use fixed structures is 8.3 years, and the maximum - 14.3 years. The analysis in this country, according to the average data, gives the period of use of fixed structures 5.8 years, one crowns - 6.3 years. The aim of the study was to establish the causes leading to a decrease in frequency of use of orthopedic constructions. Materials and methods. For qualitative research prosthetics and the term of use removable dentures which are made in prosthetic dentistry clinic Poltava regional dental clinic we analyzed indicators restore chewing efficiency in 130 patients (38 men and 92 women), who addressed the orthopedic department for 2012-2014 and who for medical reasons have been removed fixed constructions. It fixed prosthesis 141 removed, 101 of them (79%) of the metal 23 (20.7%) and only a combined 7 (3%) plastics. With single-sided support (cantilever) prostheses 29 (20.7%), two - 101 (72%) with constituents - 9 (6.5%) and a quadrilateral - 2 (0.4%). In addition to bridges, was also removed 44 rare crowns. The main reasons that lead to a decrease in the frequency of use dentures, according to the literature are: dental caries and its complications, breaking bridges, periodontal inflammation, regional periodontal roztsementuvannya and others. The analysis shows that the largest number of patients (43 -30.49%) used prostheses 6-10 years. During inspection and assessment of quality indicators of fixed structures should be noted about their poor quality as the fault of dental laboratories (Table 3) and for non-compliance dentist - orthopedist (Table 4), which, in our opinion, and led to their withdrawal. By prosthetics with 310 teeth were treated with 54 (17.5%), after removing the prosthesis 70 (22.7%) teeth were destroyed, what prompted roztsementuvannya and retraction of the gingival margin. After removing the prosthesis, we studied the prepared teeth and note that 205 (66.4%) cases were properly prepared and the prepared, and 104 (33.6%) admitted physicians various errors. To determine the reduction of marginal periodontal abutments used sample Pisarev - Schiller, as a result of which found that 226 (78.8%) cases it was positive, and in 84 (27.2%) negative. These tests were performed only in patients without clinical signs of periodontitis and phenomena parodontopatii. Conclusions. These data indicate a phenomenon sources chronic infection caused by the prosthesis. Therefore, failure to comply with the rules and requirements to prostheses, as well as the negativity of the same design used in different people may have different manifestations, depending on the individual structure and condition of the oral cavity. The indications and contraindications as well as to prosthetic teeth are pathological conditions as in the first case (as reading), found dentures and in the second case, as contraindications.
first_indexed 2024-12-14T05:13:30Z
format Article
id doaj.art-ab70d16678134f77b0347972efd2a42d
institution Directory Open Access Journal
issn 2409-0255
2410-1427
language English
last_indexed 2024-12-14T05:13:30Z
publishDate 2015-03-01
publisher Ukrainian Medical Stomatological Academy
record_format Article
series Український стоматологічний альманах
spelling doaj.art-ab70d16678134f77b0347972efd2a42d2022-12-21T23:15:53ZengUkrainian Medical Stomatological AcademyУкраїнський стоматологічний альманах2409-02552410-14272015-03-011535611THE REASONS THAT LEAD TO THE REDUCTION OF THE USE OF NON-REMOVABLE PROSTHESIS DESIGNSM.J. Nidzelskyy0N.V. Tsvetkova1S.S. Yasnogorskaya2State Higher Educational Institution Ukraine "Ukrainian Medical Stomatological Academy" Department of postgraduate education of dentists, orthopedists, t. PoltavaState Higher Educational Institution Ukraine "Ukrainian Medical Stomatological Academy" Department of postgraduate education of dentists, orthopedists, t. PoltavaState Higher Educational Institution Ukraine "Ukrainian Medical Stomatological Academy" Department of postgraduate education of dentists, orthopedists, t. PoltavaIntroduction. Treatment of patients in the clinic of orthopedic dentistry is designed not only to restore function and prevention of complications resulting from dental system damage, as well as the return of the patient to the appropriate aesthetic and cosmetic appearance. Share in the total amount of all non-removable denture designs, according to different authors, from 70 to 93%. Different figure needs of the population in nonremovable dentures is a relative through nevidtvorennya pictures re prosthetics and clinic visits. In the United States, according to Welton SN, Gardner PM, the average term to use fixed structures is 8.3 years, and the maximum - 14.3 years. The analysis in this country, according to the average data, gives the period of use of fixed structures 5.8 years, one crowns - 6.3 years. The aim of the study was to establish the causes leading to a decrease in frequency of use of orthopedic constructions. Materials and methods. For qualitative research prosthetics and the term of use removable dentures which are made in prosthetic dentistry clinic Poltava regional dental clinic we analyzed indicators restore chewing efficiency in 130 patients (38 men and 92 women), who addressed the orthopedic department for 2012-2014 and who for medical reasons have been removed fixed constructions. It fixed prosthesis 141 removed, 101 of them (79%) of the metal 23 (20.7%) and only a combined 7 (3%) plastics. With single-sided support (cantilever) prostheses 29 (20.7%), two - 101 (72%) with constituents - 9 (6.5%) and a quadrilateral - 2 (0.4%). In addition to bridges, was also removed 44 rare crowns. The main reasons that lead to a decrease in the frequency of use dentures, according to the literature are: dental caries and its complications, breaking bridges, periodontal inflammation, regional periodontal roztsementuvannya and others. The analysis shows that the largest number of patients (43 -30.49%) used prostheses 6-10 years. During inspection and assessment of quality indicators of fixed structures should be noted about their poor quality as the fault of dental laboratories (Table 3) and for non-compliance dentist - orthopedist (Table 4), which, in our opinion, and led to their withdrawal. By prosthetics with 310 teeth were treated with 54 (17.5%), after removing the prosthesis 70 (22.7%) teeth were destroyed, what prompted roztsementuvannya and retraction of the gingival margin. After removing the prosthesis, we studied the prepared teeth and note that 205 (66.4%) cases were properly prepared and the prepared, and 104 (33.6%) admitted physicians various errors. To determine the reduction of marginal periodontal abutments used sample Pisarev - Schiller, as a result of which found that 226 (78.8%) cases it was positive, and in 84 (27.2%) negative. These tests were performed only in patients without clinical signs of periodontitis and phenomena parodontopatii. Conclusions. These data indicate a phenomenon sources chronic infection caused by the prosthesis. Therefore, failure to comply with the rules and requirements to prostheses, as well as the negativity of the same design used in different people may have different manifestations, depending on the individual structure and condition of the oral cavity. The indications and contraindications as well as to prosthetic teeth are pathological conditions as in the first case (as reading), found dentures and in the second case, as contraindications.https://dental-almanac.org/index.php/journal/article/view/11orthopedic design, fixed dentures term use.
spellingShingle M.J. Nidzelskyy
N.V. Tsvetkova
S.S. Yasnogorskaya
THE REASONS THAT LEAD TO THE REDUCTION OF THE USE OF NON-REMOVABLE PROSTHESIS DESIGNS
Український стоматологічний альманах
orthopedic design, fixed dentures term use.
title THE REASONS THAT LEAD TO THE REDUCTION OF THE USE OF NON-REMOVABLE PROSTHESIS DESIGNS
title_full THE REASONS THAT LEAD TO THE REDUCTION OF THE USE OF NON-REMOVABLE PROSTHESIS DESIGNS
title_fullStr THE REASONS THAT LEAD TO THE REDUCTION OF THE USE OF NON-REMOVABLE PROSTHESIS DESIGNS
title_full_unstemmed THE REASONS THAT LEAD TO THE REDUCTION OF THE USE OF NON-REMOVABLE PROSTHESIS DESIGNS
title_short THE REASONS THAT LEAD TO THE REDUCTION OF THE USE OF NON-REMOVABLE PROSTHESIS DESIGNS
title_sort reasons that lead to the reduction of the use of non removable prosthesis designs
topic orthopedic design, fixed dentures term use.
url https://dental-almanac.org/index.php/journal/article/view/11
work_keys_str_mv AT mjnidzelskyy thereasonsthatleadtothereductionoftheuseofnonremovableprosthesisdesigns
AT nvtsvetkova thereasonsthatleadtothereductionoftheuseofnonremovableprosthesisdesigns
AT ssyasnogorskaya thereasonsthatleadtothereductionoftheuseofnonremovableprosthesisdesigns
AT mjnidzelskyy reasonsthatleadtothereductionoftheuseofnonremovableprosthesisdesigns
AT nvtsvetkova reasonsthatleadtothereductionoftheuseofnonremovableprosthesisdesigns
AT ssyasnogorskaya reasonsthatleadtothereductionoftheuseofnonremovableprosthesisdesigns