Enhanced Fault Detection and Localization Strategy for High-Speed Protection in Medium-Voltage DC Distribution Networks Using Extended Kalman Filtering Algorithm

Conventional strategies are not effective in addressing the complex protection challenges in medium-voltage DC distribution networks (MVDCDN). The main challenge in MVDCDN is the high-rising DC fault current, requiring a robust and fast protection strategy. This paper proposes the use of an Extended...

Full description

Bibliographic Details
Main Authors: Nauman Ali Larik, Meng Shi Li, Qing Hua Wu
Format: Article
Language:English
Published: IEEE 2024-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/10444101/
_version_ 1797272706685599744
author Nauman Ali Larik
Meng Shi Li
Qing Hua Wu
author_facet Nauman Ali Larik
Meng Shi Li
Qing Hua Wu
author_sort Nauman Ali Larik
collection DOAJ
description Conventional strategies are not effective in addressing the complex protection challenges in medium-voltage DC distribution networks (MVDCDN). The main challenge in MVDCDN is the high-rising DC fault current, requiring a robust and fast protection strategy. This paper proposes the use of an Extended Kalman filter (EKF) to detect various types of DC faults using only the current signal in the MVDCDN. In the first stage, current signals from the positive and negative poles corresponding bus are obtained. The EKF is then applied to the measured DC-current signals to generate two fault detection indices. The first index is the cumulative residuals (CR), calculated using the EKF iterative differencing process with updated current estimated state and noisy measurement. The second index is the modified DC version of total harmonic distortion, known as DC distortion factor (DCDF). The fault classification/zone identification (FCZI) unit is activated if changes in CR and DCDF are detected within the observation window of the relay. In the second stage, the FCZI unit calculates the Extended Kalman filter-based predicted energy (EKFBPE) for the faulty DC line section at both ends. The polarity of EKFBPE is used for fault classification and localization decisions. The proposed protection strategy requires low-band wireless communication capability in the smart grid. Extensive simulations using MATLAB Ⓡ Simulink 2022b are conducted on a ±2.5 kV MVDCDN with three feeders, considering various fault scenarios. The results demonstrate that the proposed scheme achieves 99.9% accuracy, under radial, looped, and meshed topology and is highly resilient to different types of faults with time of operation 1 msec. The scalability of proposed method and its effectiveness in handling higher voltage levels and associated fault uncertainty will investigate in future research.
first_indexed 2024-03-07T14:33:13Z
format Article
id doaj.art-ac8e14df9ce34499b2d906b6fbd93d96
institution Directory Open Access Journal
issn 2169-3536
language English
last_indexed 2024-03-07T14:33:13Z
publishDate 2024-01-01
publisher IEEE
record_format Article
series IEEE Access
spelling doaj.art-ac8e14df9ce34499b2d906b6fbd93d962024-03-06T00:01:12ZengIEEEIEEE Access2169-35362024-01-0112303293034410.1109/ACCESS.2024.336941810444101Enhanced Fault Detection and Localization Strategy for High-Speed Protection in Medium-Voltage DC Distribution Networks Using Extended Kalman Filtering AlgorithmNauman Ali Larik0Meng Shi Li1https://orcid.org/0000-0001-7044-1782Qing Hua Wu2https://orcid.org/0000-0002-0598-8367School of Electric Power Engineering, South China University of Technology, Guangzhou, ChinaSchool of Electric Power Engineering, South China University of Technology, Guangzhou, ChinaSchool of Electric Power Engineering, South China University of Technology, Guangzhou, ChinaConventional strategies are not effective in addressing the complex protection challenges in medium-voltage DC distribution networks (MVDCDN). The main challenge in MVDCDN is the high-rising DC fault current, requiring a robust and fast protection strategy. This paper proposes the use of an Extended Kalman filter (EKF) to detect various types of DC faults using only the current signal in the MVDCDN. In the first stage, current signals from the positive and negative poles corresponding bus are obtained. The EKF is then applied to the measured DC-current signals to generate two fault detection indices. The first index is the cumulative residuals (CR), calculated using the EKF iterative differencing process with updated current estimated state and noisy measurement. The second index is the modified DC version of total harmonic distortion, known as DC distortion factor (DCDF). The fault classification/zone identification (FCZI) unit is activated if changes in CR and DCDF are detected within the observation window of the relay. In the second stage, the FCZI unit calculates the Extended Kalman filter-based predicted energy (EKFBPE) for the faulty DC line section at both ends. The polarity of EKFBPE is used for fault classification and localization decisions. The proposed protection strategy requires low-band wireless communication capability in the smart grid. Extensive simulations using MATLAB Ⓡ Simulink 2022b are conducted on a ±2.5 kV MVDCDN with three feeders, considering various fault scenarios. The results demonstrate that the proposed scheme achieves 99.9% accuracy, under radial, looped, and meshed topology and is highly resilient to different types of faults with time of operation 1 msec. The scalability of proposed method and its effectiveness in handling higher voltage levels and associated fault uncertainty will investigate in future research.https://ieeexplore.ieee.org/document/10444101/Fault detectionfault zone identificationDC distribution networksDC microgridsextended Kalman filters
spellingShingle Nauman Ali Larik
Meng Shi Li
Qing Hua Wu
Enhanced Fault Detection and Localization Strategy for High-Speed Protection in Medium-Voltage DC Distribution Networks Using Extended Kalman Filtering Algorithm
IEEE Access
Fault detection
fault zone identification
DC distribution networks
DC microgrids
extended Kalman filters
title Enhanced Fault Detection and Localization Strategy for High-Speed Protection in Medium-Voltage DC Distribution Networks Using Extended Kalman Filtering Algorithm
title_full Enhanced Fault Detection and Localization Strategy for High-Speed Protection in Medium-Voltage DC Distribution Networks Using Extended Kalman Filtering Algorithm
title_fullStr Enhanced Fault Detection and Localization Strategy for High-Speed Protection in Medium-Voltage DC Distribution Networks Using Extended Kalman Filtering Algorithm
title_full_unstemmed Enhanced Fault Detection and Localization Strategy for High-Speed Protection in Medium-Voltage DC Distribution Networks Using Extended Kalman Filtering Algorithm
title_short Enhanced Fault Detection and Localization Strategy for High-Speed Protection in Medium-Voltage DC Distribution Networks Using Extended Kalman Filtering Algorithm
title_sort enhanced fault detection and localization strategy for high speed protection in medium voltage dc distribution networks using extended kalman filtering algorithm
topic Fault detection
fault zone identification
DC distribution networks
DC microgrids
extended Kalman filters
url https://ieeexplore.ieee.org/document/10444101/
work_keys_str_mv AT naumanalilarik enhancedfaultdetectionandlocalizationstrategyforhighspeedprotectioninmediumvoltagedcdistributionnetworksusingextendedkalmanfilteringalgorithm
AT mengshili enhancedfaultdetectionandlocalizationstrategyforhighspeedprotectioninmediumvoltagedcdistributionnetworksusingextendedkalmanfilteringalgorithm
AT qinghuawu enhancedfaultdetectionandlocalizationstrategyforhighspeedprotectioninmediumvoltagedcdistributionnetworksusingextendedkalmanfilteringalgorithm