The Effect of Increasing Sub-Cooling on Air-Cooled A/C System's Capacity

The present research covers the effect of adding an extra water-cooled condenser in series with the main vapor compression refrigeration system as a heat sink source for system sub-cooling. An experimental laboratory study has been done on a split unit air conditioner with a (24000 Btu/hr) nominal...

Full description

Bibliographic Details
Main Authors: Ghanim K. Abdul Sada, M. N. Hamid, Arkan F. Said
Format: Article
Language:Arabic
Published: Mustansiriyah University/College of Engineering 2009-03-01
Series:Journal of Engineering and Sustainable Development
Subjects:
.
Online Access:https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1529
_version_ 1797984981938601984
author Ghanim K. Abdul Sada
M. N. Hamid
Arkan F. Said
author_facet Ghanim K. Abdul Sada
M. N. Hamid
Arkan F. Said
author_sort Ghanim K. Abdul Sada
collection DOAJ
description The present research covers the effect of adding an extra water-cooled condenser in series with the main vapor compression refrigeration system as a heat sink source for system sub-cooling. An experimental laboratory study has been done on a split unit air conditioner with a (24000 Btu/hr) nominal capacity, taking into consideration the effect of outdoor ambient temperature and cooling load. A high accuracy fully instrumented experimental rig interfaced with a computer has been constructed, specially designed for refrigerant R22, using a capillary tube with a size chosen according to ASHRAE to control the refrigerant mass flow rate. The extra refrigerant sub-cooling temperature difference was between TSC= 5 oC and 10oC, this value was chosen in order to not exceed the limits of the original system sub-cooling. The experimental results show that there is an increase in the system capacity by +1.37% to +7.065% when TSC= 5 oC, for ambient temperature between Tamb=30 oC and 46oC, and +4.1% to +14.13% when TSC= 10oC for the same previous Tamb. The power consumed per ton of refrigeration shows a decrease by -0.948% to -3.417% for TSC= 5oC, and -2.84% to -7.745% for TSC= 10 oC for the same ambient temperature previously mentioned......
first_indexed 2024-04-11T07:11:31Z
format Article
id doaj.art-ad2c7f89005e42b2b91c3b7a46e08231
institution Directory Open Access Journal
issn 2520-0917
2520-0925
language Arabic
last_indexed 2024-04-11T07:11:31Z
publishDate 2009-03-01
publisher Mustansiriyah University/College of Engineering
record_format Article
series Journal of Engineering and Sustainable Development
spelling doaj.art-ad2c7f89005e42b2b91c3b7a46e082312022-12-22T04:38:12ZaraMustansiriyah University/College of EngineeringJournal of Engineering and Sustainable Development2520-09172520-09252009-03-01131The Effect of Increasing Sub-Cooling on Air-Cooled A/C System's CapacityGhanim K. Abdul Sada0M. N. Hamid1Arkan F. Said2Mechanical Engineering Department, Al-Mustansiriyah University , Baghdad, IraqMechanical Engineering Department, Al-Mustansiriyah University , Baghdad, IraqPower Production Office, Ministry of Electricity, Baghdad, Iraq The present research covers the effect of adding an extra water-cooled condenser in series with the main vapor compression refrigeration system as a heat sink source for system sub-cooling. An experimental laboratory study has been done on a split unit air conditioner with a (24000 Btu/hr) nominal capacity, taking into consideration the effect of outdoor ambient temperature and cooling load. A high accuracy fully instrumented experimental rig interfaced with a computer has been constructed, specially designed for refrigerant R22, using a capillary tube with a size chosen according to ASHRAE to control the refrigerant mass flow rate. The extra refrigerant sub-cooling temperature difference was between TSC= 5 oC and 10oC, this value was chosen in order to not exceed the limits of the original system sub-cooling. The experimental results show that there is an increase in the system capacity by +1.37% to +7.065% when TSC= 5 oC, for ambient temperature between Tamb=30 oC and 46oC, and +4.1% to +14.13% when TSC= 10oC for the same previous Tamb. The power consumed per ton of refrigeration shows a decrease by -0.948% to -3.417% for TSC= 5oC, and -2.84% to -7.745% for TSC= 10 oC for the same ambient temperature previously mentioned...... https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1529.
spellingShingle Ghanim K. Abdul Sada
M. N. Hamid
Arkan F. Said
The Effect of Increasing Sub-Cooling on Air-Cooled A/C System's Capacity
Journal of Engineering and Sustainable Development
.
title The Effect of Increasing Sub-Cooling on Air-Cooled A/C System's Capacity
title_full The Effect of Increasing Sub-Cooling on Air-Cooled A/C System's Capacity
title_fullStr The Effect of Increasing Sub-Cooling on Air-Cooled A/C System's Capacity
title_full_unstemmed The Effect of Increasing Sub-Cooling on Air-Cooled A/C System's Capacity
title_short The Effect of Increasing Sub-Cooling on Air-Cooled A/C System's Capacity
title_sort effect of increasing sub cooling on air cooled a c system s capacity
topic .
url https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1529
work_keys_str_mv AT ghanimkabdulsada theeffectofincreasingsubcoolingonaircooledacsystemscapacity
AT mnhamid theeffectofincreasingsubcoolingonaircooledacsystemscapacity
AT arkanfsaid theeffectofincreasingsubcoolingonaircooledacsystemscapacity
AT ghanimkabdulsada effectofincreasingsubcoolingonaircooledacsystemscapacity
AT mnhamid effectofincreasingsubcoolingonaircooledacsystemscapacity
AT arkanfsaid effectofincreasingsubcoolingonaircooledacsystemscapacity