Vaginal and vestibular electrical resistance as an alternative marker for optimum timing of artificial insemination with liquid-stored and frozen-thawed spermatozoa in sows
Abstract Development of a pen-side test to objectively determine the ideal time for artificial insemination (AI) in the sow would save producers time and money. Current processes rely on identification of oestrus via subjective behavioural and physiological markers that are indicative of high blood...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Nature Portfolio
2023-07-01
|
Series: | Scientific Reports |
Online Access: | https://doi.org/10.1038/s41598-023-38803-5 |
_version_ | 1797769519473623040 |
---|---|
author | Dannielle Glencorse Christopher G. Grupen Roslyn Bathgate |
author_facet | Dannielle Glencorse Christopher G. Grupen Roslyn Bathgate |
author_sort | Dannielle Glencorse |
collection | DOAJ |
description | Abstract Development of a pen-side test to objectively determine the ideal time for artificial insemination (AI) in the sow would save producers time and money. Current processes rely on identification of oestrus via subjective behavioural and physiological markers that are indicative of high blood oestrogen concentrations. This study attempted to use measurements of electrical resistance (ER) in the cervical mucus to pinpoint timing of AI accurately enough to lead to equivalent pregnancy rates as a natural mating. Thirty-six sows were divided into 3 groups and observed for signs of oestrus. Seven sows did not show any oestrus behaviour and were excluded from the study. The remaining 29 sows were inseminated via natural mating and conventional oestrus detection (n = 14), or inseminated artificially with either liquid-stored semen (n = 8) or frozen-thawed semen (n = 7) according to timing indicated from electrical resistance measurements in the vagina and vestibule. Sows that were artificially inseminated on the basis of the electrical resistance readings had a lower pregnancy rate (P = 0.034) and less piglets born alive per litter (P < 0.05) than those that were naturally mated according to a conventional oestrus detection regime. However, the pregnancy rate and total piglets born alive did not differ between the two groups that underwent artificial insemination. Change in electrical resistance in the vagina has the potential to accurately predict ovulation timing, but more work is required to refine the timing of AI in relation to the readings before the technique can be adopted by industry. |
first_indexed | 2024-03-12T21:10:16Z |
format | Article |
id | doaj.art-ad30068943e74055b11463ee330d7817 |
institution | Directory Open Access Journal |
issn | 2045-2322 |
language | English |
last_indexed | 2024-03-12T21:10:16Z |
publishDate | 2023-07-01 |
publisher | Nature Portfolio |
record_format | Article |
series | Scientific Reports |
spelling | doaj.art-ad30068943e74055b11463ee330d78172023-07-30T11:14:07ZengNature PortfolioScientific Reports2045-23222023-07-011311810.1038/s41598-023-38803-5Vaginal and vestibular electrical resistance as an alternative marker for optimum timing of artificial insemination with liquid-stored and frozen-thawed spermatozoa in sowsDannielle Glencorse0Christopher G. Grupen1Roslyn Bathgate2Sydney School of Veterinary Science, Faculty of Science, The University of SydneySydney School of Veterinary Science, Faculty of Science, The University of SydneySydney School of Veterinary Science, Faculty of Science, The University of SydneyAbstract Development of a pen-side test to objectively determine the ideal time for artificial insemination (AI) in the sow would save producers time and money. Current processes rely on identification of oestrus via subjective behavioural and physiological markers that are indicative of high blood oestrogen concentrations. This study attempted to use measurements of electrical resistance (ER) in the cervical mucus to pinpoint timing of AI accurately enough to lead to equivalent pregnancy rates as a natural mating. Thirty-six sows were divided into 3 groups and observed for signs of oestrus. Seven sows did not show any oestrus behaviour and were excluded from the study. The remaining 29 sows were inseminated via natural mating and conventional oestrus detection (n = 14), or inseminated artificially with either liquid-stored semen (n = 8) or frozen-thawed semen (n = 7) according to timing indicated from electrical resistance measurements in the vagina and vestibule. Sows that were artificially inseminated on the basis of the electrical resistance readings had a lower pregnancy rate (P = 0.034) and less piglets born alive per litter (P < 0.05) than those that were naturally mated according to a conventional oestrus detection regime. However, the pregnancy rate and total piglets born alive did not differ between the two groups that underwent artificial insemination. Change in electrical resistance in the vagina has the potential to accurately predict ovulation timing, but more work is required to refine the timing of AI in relation to the readings before the technique can be adopted by industry.https://doi.org/10.1038/s41598-023-38803-5 |
spellingShingle | Dannielle Glencorse Christopher G. Grupen Roslyn Bathgate Vaginal and vestibular electrical resistance as an alternative marker for optimum timing of artificial insemination with liquid-stored and frozen-thawed spermatozoa in sows Scientific Reports |
title | Vaginal and vestibular electrical resistance as an alternative marker for optimum timing of artificial insemination with liquid-stored and frozen-thawed spermatozoa in sows |
title_full | Vaginal and vestibular electrical resistance as an alternative marker for optimum timing of artificial insemination with liquid-stored and frozen-thawed spermatozoa in sows |
title_fullStr | Vaginal and vestibular electrical resistance as an alternative marker for optimum timing of artificial insemination with liquid-stored and frozen-thawed spermatozoa in sows |
title_full_unstemmed | Vaginal and vestibular electrical resistance as an alternative marker for optimum timing of artificial insemination with liquid-stored and frozen-thawed spermatozoa in sows |
title_short | Vaginal and vestibular electrical resistance as an alternative marker for optimum timing of artificial insemination with liquid-stored and frozen-thawed spermatozoa in sows |
title_sort | vaginal and vestibular electrical resistance as an alternative marker for optimum timing of artificial insemination with liquid stored and frozen thawed spermatozoa in sows |
url | https://doi.org/10.1038/s41598-023-38803-5 |
work_keys_str_mv | AT dannielleglencorse vaginalandvestibularelectricalresistanceasanalternativemarkerforoptimumtimingofartificialinseminationwithliquidstoredandfrozenthawedspermatozoainsows AT christopherggrupen vaginalandvestibularelectricalresistanceasanalternativemarkerforoptimumtimingofartificialinseminationwithliquidstoredandfrozenthawedspermatozoainsows AT roslynbathgate vaginalandvestibularelectricalresistanceasanalternativemarkerforoptimumtimingofartificialinseminationwithliquidstoredandfrozenthawedspermatozoainsows |