Retinal and Choroidal Changes Following Implantable Collamer Lens V4c Implantation in High Myopia Patients—A 1-Year Follow-Up Study

This prospective study aimed to evaluate the impact of Visian Implantable Collamer Lens (ICL) V4c implantation on retinal and choroidal morphology in patients with high myopia. A total of 97 eyes from 52 high myopic patients who underwent ICL V4c implantation were followed up for 12 months. Preopera...

Full description

Bibliographic Details
Main Authors: Qiaoling Wei, Xianjin Zhou, Weiteng Chang, Rui Jiang, Xingtao Zhou, Zhiqiang Yu
Format: Article
Language:English
Published: MDPI AG 2023-09-01
Series:Diagnostics
Subjects:
Online Access:https://www.mdpi.com/2075-4418/13/19/3097
_version_ 1827722715928199168
author Qiaoling Wei
Xianjin Zhou
Weiteng Chang
Rui Jiang
Xingtao Zhou
Zhiqiang Yu
author_facet Qiaoling Wei
Xianjin Zhou
Weiteng Chang
Rui Jiang
Xingtao Zhou
Zhiqiang Yu
author_sort Qiaoling Wei
collection DOAJ
description This prospective study aimed to evaluate the impact of Visian Implantable Collamer Lens (ICL) V4c implantation on retinal and choroidal morphology in patients with high myopia. A total of 97 eyes from 52 high myopic patients who underwent ICL V4c implantation were followed up for 12 months. Preoperative and postoperative evaluations included comprehensive ophthalmic assessments and enhanced depth imaging optical coherence tomography (EDI-OCT) to analyze changes in central retinal thickness (CRT), retinal volume (CRV), choroidal thickness (ChT), total choroidal area (TCA), luminal area (LA), and choroidal vascular index (CVI). Repeated measures mixed-effects models were used for comparing pre- and postoperative measurement variables and exploring relationships among age, axial length (AL), spherical equivalent refraction (SER), and postoperative retinal and choroidal changes, with statistical significance set at <i>p</i> < 0.05. Follow-up assessments were conducted at various time points, with participation rates ranging from 21% to 98%. Baseline characteristics showed a median age of 26.7 years, −10.14 diopters of SER, and an AL of 27.44 mm. Throughout the 12-month follow-up, CRT and 3.0 mm CRV consistently increased compared to the baseline, with statistically significant rises observed at postoperative day 1, week 1, and month 12. Most ChT measurements, including subfoveal ChT, declined over the 12 months, except at postoperative 6 months. Horizontal and vertical TCA and LA values significantly increased throughout the follow-up, except for month 6. After surgery, both horizontal and vertical CVI parameters exhibited an increase compared to the baseline, with some changes reaching statistical significance. Correlation analysis performed by repeated measures mixed-effects models showed that no relationship was found between age, AL, and SER and changes in postoperative retinal parameters and CVI parameters. However, postoperative changes in ChT and choroidal area parameters showed a negative correlation with AL and a positive correlation with SER. Our research demonstrated that ICL V4c implantation resulted in noteworthy alterations in retinal and choroidal morphology over a 1-year follow-up period. Moreover, in patients with high myopia, individuals with longer AL and higher degrees of myopia exhibited more pronounced postoperative changes in the choroid and retina. Further studies with extended follow-up durations are necessary to comprehensively understand the long-term effects of ICL implantation on retinal and choroidal morphology and function.
first_indexed 2024-03-10T21:46:55Z
format Article
id doaj.art-ad3d3b057a154dadaad384fdd5c38183
institution Directory Open Access Journal
issn 2075-4418
language English
last_indexed 2024-03-10T21:46:55Z
publishDate 2023-09-01
publisher MDPI AG
record_format Article
series Diagnostics
spelling doaj.art-ad3d3b057a154dadaad384fdd5c381832023-11-19T14:14:43ZengMDPI AGDiagnostics2075-44182023-09-011319309710.3390/diagnostics13193097Retinal and Choroidal Changes Following Implantable Collamer Lens V4c Implantation in High Myopia Patients—A 1-Year Follow-Up StudyQiaoling Wei0Xianjin Zhou1Weiteng Chang2Rui Jiang3Xingtao Zhou4Zhiqiang Yu5Department of Ophthalmology, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai 200031, ChinaDepartment of Ophthalmology, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai 200031, ChinaDepartment of Ophthalmology, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai 200031, ChinaDepartment of Ophthalmology, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai 200031, ChinaDepartment of Ophthalmology, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai 200031, ChinaDepartment of Ophthalmology, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai 200031, ChinaThis prospective study aimed to evaluate the impact of Visian Implantable Collamer Lens (ICL) V4c implantation on retinal and choroidal morphology in patients with high myopia. A total of 97 eyes from 52 high myopic patients who underwent ICL V4c implantation were followed up for 12 months. Preoperative and postoperative evaluations included comprehensive ophthalmic assessments and enhanced depth imaging optical coherence tomography (EDI-OCT) to analyze changes in central retinal thickness (CRT), retinal volume (CRV), choroidal thickness (ChT), total choroidal area (TCA), luminal area (LA), and choroidal vascular index (CVI). Repeated measures mixed-effects models were used for comparing pre- and postoperative measurement variables and exploring relationships among age, axial length (AL), spherical equivalent refraction (SER), and postoperative retinal and choroidal changes, with statistical significance set at <i>p</i> < 0.05. Follow-up assessments were conducted at various time points, with participation rates ranging from 21% to 98%. Baseline characteristics showed a median age of 26.7 years, −10.14 diopters of SER, and an AL of 27.44 mm. Throughout the 12-month follow-up, CRT and 3.0 mm CRV consistently increased compared to the baseline, with statistically significant rises observed at postoperative day 1, week 1, and month 12. Most ChT measurements, including subfoveal ChT, declined over the 12 months, except at postoperative 6 months. Horizontal and vertical TCA and LA values significantly increased throughout the follow-up, except for month 6. After surgery, both horizontal and vertical CVI parameters exhibited an increase compared to the baseline, with some changes reaching statistical significance. Correlation analysis performed by repeated measures mixed-effects models showed that no relationship was found between age, AL, and SER and changes in postoperative retinal parameters and CVI parameters. However, postoperative changes in ChT and choroidal area parameters showed a negative correlation with AL and a positive correlation with SER. Our research demonstrated that ICL V4c implantation resulted in noteworthy alterations in retinal and choroidal morphology over a 1-year follow-up period. Moreover, in patients with high myopia, individuals with longer AL and higher degrees of myopia exhibited more pronounced postoperative changes in the choroid and retina. Further studies with extended follow-up durations are necessary to comprehensively understand the long-term effects of ICL implantation on retinal and choroidal morphology and function.https://www.mdpi.com/2075-4418/13/19/3097implantable collamer lensICLretinal thicknesschoroidal thicknesschoroidal vascular indexenhanced depth imaging optical coherence tomography
spellingShingle Qiaoling Wei
Xianjin Zhou
Weiteng Chang
Rui Jiang
Xingtao Zhou
Zhiqiang Yu
Retinal and Choroidal Changes Following Implantable Collamer Lens V4c Implantation in High Myopia Patients—A 1-Year Follow-Up Study
Diagnostics
implantable collamer lens
ICL
retinal thickness
choroidal thickness
choroidal vascular index
enhanced depth imaging optical coherence tomography
title Retinal and Choroidal Changes Following Implantable Collamer Lens V4c Implantation in High Myopia Patients—A 1-Year Follow-Up Study
title_full Retinal and Choroidal Changes Following Implantable Collamer Lens V4c Implantation in High Myopia Patients—A 1-Year Follow-Up Study
title_fullStr Retinal and Choroidal Changes Following Implantable Collamer Lens V4c Implantation in High Myopia Patients—A 1-Year Follow-Up Study
title_full_unstemmed Retinal and Choroidal Changes Following Implantable Collamer Lens V4c Implantation in High Myopia Patients—A 1-Year Follow-Up Study
title_short Retinal and Choroidal Changes Following Implantable Collamer Lens V4c Implantation in High Myopia Patients—A 1-Year Follow-Up Study
title_sort retinal and choroidal changes following implantable collamer lens v4c implantation in high myopia patients a 1 year follow up study
topic implantable collamer lens
ICL
retinal thickness
choroidal thickness
choroidal vascular index
enhanced depth imaging optical coherence tomography
url https://www.mdpi.com/2075-4418/13/19/3097
work_keys_str_mv AT qiaolingwei retinalandchoroidalchangesfollowingimplantablecollamerlensv4cimplantationinhighmyopiapatientsa1yearfollowupstudy
AT xianjinzhou retinalandchoroidalchangesfollowingimplantablecollamerlensv4cimplantationinhighmyopiapatientsa1yearfollowupstudy
AT weitengchang retinalandchoroidalchangesfollowingimplantablecollamerlensv4cimplantationinhighmyopiapatientsa1yearfollowupstudy
AT ruijiang retinalandchoroidalchangesfollowingimplantablecollamerlensv4cimplantationinhighmyopiapatientsa1yearfollowupstudy
AT xingtaozhou retinalandchoroidalchangesfollowingimplantablecollamerlensv4cimplantationinhighmyopiapatientsa1yearfollowupstudy
AT zhiqiangyu retinalandchoroidalchangesfollowingimplantablecollamerlensv4cimplantationinhighmyopiapatientsa1yearfollowupstudy