Mercury emissions from polish pulverized coalfired boiler

The current paper presents the research results carried out at one of Polish power plants at a pulverized hard coal-fired 225 MW unit. The research was carried out at full load of the boiler (100% MCR) and focused on analysis of mercury content in the input fuel and limestone sorbent for wet flue ga...

Full description

Bibliographic Details
Main Authors: Wichliński Michał, Wielgosz Grzegorz, Kobyłecki Rafał
Format: Article
Language:English
Published: EDP Sciences 2017-01-01
Series:E3S Web of Conferences
Online Access:https://doi.org/10.1051/e3sconf/20171402008
_version_ 1818578896042328064
author Wichliński Michał
Wielgosz Grzegorz
Kobyłecki Rafał
author_facet Wichliński Michał
Wielgosz Grzegorz
Kobyłecki Rafał
author_sort Wichliński Michał
collection DOAJ
description The current paper presents the research results carried out at one of Polish power plants at a pulverized hard coal-fired 225 MW unit. The research was carried out at full load of the boiler (100% MCR) and focused on analysis of mercury content in the input fuel and limestone sorbent for wet flue gas desulfurization (FGD) system, as well as investigation of mercury content in the combustion products, i.e. fly ash, slag, FGD product (gypsum) and FGD effluents (waste). Within the framework of the present study the concentration of mercury vapor in the exhaust gas was also investigated. The analysis was performed using Lumex RA-915+ spectrometer with an attachment (RP-91C). The measurements were carried out at three locations, i.e. before the electrostatic precipitator (ESP), downstream the ESP, and downstream the wet FGD plant. Design of the measurement system allowed to determine both forms of mercury in the flue gas (Hg0 and Hg2+) at all measurement locations.Based on the measurement results the balance of mercury for a pulverized coal (PC) boiler was calculated and the amount of mercury was assessed both in the input solids (fuel and sorbent), as well as the gaseous and solids products (flue gas, slag, ash, gypsum and FGD waste).
first_indexed 2024-12-16T06:53:05Z
format Article
id doaj.art-ad502e8ec6664debb2a142860c50cfce
institution Directory Open Access Journal
issn 2267-1242
language English
last_indexed 2024-12-16T06:53:05Z
publishDate 2017-01-01
publisher EDP Sciences
record_format Article
series E3S Web of Conferences
spelling doaj.art-ad502e8ec6664debb2a142860c50cfce2022-12-21T22:40:21ZengEDP SciencesE3S Web of Conferences2267-12422017-01-01140200810.1051/e3sconf/20171402008e3sconf_ef2017_02008Mercury emissions from polish pulverized coalfired boilerWichliński Michał0Wielgosz Grzegorz1Kobyłecki Rafał2Energy Engineering Department, Faculty of Infrastructure and Environment, Czestochowa University of TechnologyEnergy Engineering Department, Faculty of Infrastructure and Environment, Czestochowa University of TechnologyEnergy Engineering Department, Faculty of Infrastructure and Environment, Czestochowa University of TechnologyThe current paper presents the research results carried out at one of Polish power plants at a pulverized hard coal-fired 225 MW unit. The research was carried out at full load of the boiler (100% MCR) and focused on analysis of mercury content in the input fuel and limestone sorbent for wet flue gas desulfurization (FGD) system, as well as investigation of mercury content in the combustion products, i.e. fly ash, slag, FGD product (gypsum) and FGD effluents (waste). Within the framework of the present study the concentration of mercury vapor in the exhaust gas was also investigated. The analysis was performed using Lumex RA-915+ spectrometer with an attachment (RP-91C). The measurements were carried out at three locations, i.e. before the electrostatic precipitator (ESP), downstream the ESP, and downstream the wet FGD plant. Design of the measurement system allowed to determine both forms of mercury in the flue gas (Hg0 and Hg2+) at all measurement locations.Based on the measurement results the balance of mercury for a pulverized coal (PC) boiler was calculated and the amount of mercury was assessed both in the input solids (fuel and sorbent), as well as the gaseous and solids products (flue gas, slag, ash, gypsum and FGD waste).https://doi.org/10.1051/e3sconf/20171402008
spellingShingle Wichliński Michał
Wielgosz Grzegorz
Kobyłecki Rafał
Mercury emissions from polish pulverized coalfired boiler
E3S Web of Conferences
title Mercury emissions from polish pulverized coalfired boiler
title_full Mercury emissions from polish pulverized coalfired boiler
title_fullStr Mercury emissions from polish pulverized coalfired boiler
title_full_unstemmed Mercury emissions from polish pulverized coalfired boiler
title_short Mercury emissions from polish pulverized coalfired boiler
title_sort mercury emissions from polish pulverized coalfired boiler
url https://doi.org/10.1051/e3sconf/20171402008
work_keys_str_mv AT wichlinskimichał mercuryemissionsfrompolishpulverizedcoalfiredboiler
AT wielgoszgrzegorz mercuryemissionsfrompolishpulverizedcoalfiredboiler
AT kobyłeckirafał mercuryemissionsfrompolishpulverizedcoalfiredboiler