Dosimetric Evaluation of Multislice CT Using AnthropomorphicHead Phantom

Purpose: The most general form to report dose in Multislice CT is the CTDI and DLP which are computed for several slices. The goal of the current study was to estimate actual doses and dose distribution during CT examinations in a head and neck anthropomorphic phantom. Methods: After construction of...

Full description

Bibliographic Details
Main Authors: Seyedeh Fatemeh Seyedatashi, Mitra Athari, Ahmad Bitarafan-Rajabi, Hadi Hasanzadeh, Mehravar Rafati, Hamid Reza Pouraliakbar, Ali Mohammadzadeh
Format: Article
Language:English
Published: Tehran University of Medical Sciences 2015-03-01
Series:Frontiers in Biomedical Technologies
Subjects:
Online Access:https://fbt.tums.ac.ir/index.php/fbt/article/view/40
_version_ 1811265822165827584
author Seyedeh Fatemeh Seyedatashi
Mitra Athari
Ahmad Bitarafan-Rajabi
Hadi Hasanzadeh
Mehravar Rafati
Hamid Reza Pouraliakbar
Ali Mohammadzadeh
author_facet Seyedeh Fatemeh Seyedatashi
Mitra Athari
Ahmad Bitarafan-Rajabi
Hadi Hasanzadeh
Mehravar Rafati
Hamid Reza Pouraliakbar
Ali Mohammadzadeh
author_sort Seyedeh Fatemeh Seyedatashi
collection DOAJ
description Purpose: The most general form to report dose in Multislice CT is the CTDI and DLP which are computed for several slices. The goal of the current study was to estimate actual doses and dose distribution during CT examinations in a head and neck anthropomorphic phantom. Methods: After construction of the head and neck phantom using natural bone and paraffin wax with NaCl as impurity, several places were considered in different sites to fill with badges of Gafchromic film. These places include brain, Parotid, Thyroid and Lens of eye. Phantom was scanned at CT Angio and Spiral protocols with 10 and 256 slice scanners. Results: Our findings showed that in 10 slice scanner, selected organ doses were in the range of 0.09-23.1 mSv while in the 256 slice scanner, it was in the range of 0.14-18.01 mSv. The CT Angio protocol has a higher organ dose at all. Conclusion: In CT Angio protocol, organ dose (except for the lens of eye) is lower in 10 slice compared to 256 slice CT; the brain dose in both protocols has no difference statistically. In the spiral protocol, the dose in 256 slice scanner is lower than the 10 slice scanner which might be due to higher number of detector arrays in 256 slice scanner.Thyroid dose is mainly due to scattered radiation and because of strict beam collimation; it has a small value in all protocols.
first_indexed 2024-04-12T20:30:51Z
format Article
id doaj.art-ad5051eb07f34d52904848d107afd0d8
institution Directory Open Access Journal
issn 2345-5837
language English
last_indexed 2024-04-12T20:30:51Z
publishDate 2015-03-01
publisher Tehran University of Medical Sciences
record_format Article
series Frontiers in Biomedical Technologies
spelling doaj.art-ad5051eb07f34d52904848d107afd0d82022-12-22T03:17:45ZengTehran University of Medical SciencesFrontiers in Biomedical Technologies2345-58372015-03-0121Dosimetric Evaluation of Multislice CT Using AnthropomorphicHead PhantomSeyedeh Fatemeh Seyedatashi0Mitra Athari1Ahmad Bitarafan-Rajabi2Hadi Hasanzadeh3Mehravar Rafati4Hamid Reza Pouraliakbar5Ali Mohammadzadeh6Islamic Azad University, Science and Research Branch, Tehran, Iran.Islamic Azad University, Science and Research Branch, Tehran, Iran.Cardiovascular interventional research center, Department of nuclear medicine, Rajaei Cardiovascular, Medical & Research Center, Iran University of medical sciences, Tehran, Iran.Cancer Research Center and Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, IranDepartment of Medical Physics, Faculty of Paramedical Sciences, Kashan University of Medical Science, Kashan, Iran.Rajaei Cardiovascular, Medical & Research Center, Radiology Department, Iran University of Medical sciences, Tehran, Iran.Rajaei Cardiovascular, Medical & Research Center, Radiology Department, Iran University of Medical sciences, Tehran, Iran.Purpose: The most general form to report dose in Multislice CT is the CTDI and DLP which are computed for several slices. The goal of the current study was to estimate actual doses and dose distribution during CT examinations in a head and neck anthropomorphic phantom. Methods: After construction of the head and neck phantom using natural bone and paraffin wax with NaCl as impurity, several places were considered in different sites to fill with badges of Gafchromic film. These places include brain, Parotid, Thyroid and Lens of eye. Phantom was scanned at CT Angio and Spiral protocols with 10 and 256 slice scanners. Results: Our findings showed that in 10 slice scanner, selected organ doses were in the range of 0.09-23.1 mSv while in the 256 slice scanner, it was in the range of 0.14-18.01 mSv. The CT Angio protocol has a higher organ dose at all. Conclusion: In CT Angio protocol, organ dose (except for the lens of eye) is lower in 10 slice compared to 256 slice CT; the brain dose in both protocols has no difference statistically. In the spiral protocol, the dose in 256 slice scanner is lower than the 10 slice scanner which might be due to higher number of detector arrays in 256 slice scanner.Thyroid dose is mainly due to scattered radiation and because of strict beam collimation; it has a small value in all protocols.https://fbt.tums.ac.ir/index.php/fbt/article/view/40Multidetector computed tomographyFilm dosimetryPhantomsImaging
spellingShingle Seyedeh Fatemeh Seyedatashi
Mitra Athari
Ahmad Bitarafan-Rajabi
Hadi Hasanzadeh
Mehravar Rafati
Hamid Reza Pouraliakbar
Ali Mohammadzadeh
Dosimetric Evaluation of Multislice CT Using AnthropomorphicHead Phantom
Frontiers in Biomedical Technologies
Multidetector computed tomography
Film dosimetry
Phantoms
Imaging
title Dosimetric Evaluation of Multislice CT Using AnthropomorphicHead Phantom
title_full Dosimetric Evaluation of Multislice CT Using AnthropomorphicHead Phantom
title_fullStr Dosimetric Evaluation of Multislice CT Using AnthropomorphicHead Phantom
title_full_unstemmed Dosimetric Evaluation of Multislice CT Using AnthropomorphicHead Phantom
title_short Dosimetric Evaluation of Multislice CT Using AnthropomorphicHead Phantom
title_sort dosimetric evaluation of multislice ct using anthropomorphichead phantom
topic Multidetector computed tomography
Film dosimetry
Phantoms
Imaging
url https://fbt.tums.ac.ir/index.php/fbt/article/view/40
work_keys_str_mv AT seyedehfatemehseyedatashi dosimetricevaluationofmultislicectusinganthropomorphicheadphantom
AT mitraathari dosimetricevaluationofmultislicectusinganthropomorphicheadphantom
AT ahmadbitarafanrajabi dosimetricevaluationofmultislicectusinganthropomorphicheadphantom
AT hadihasanzadeh dosimetricevaluationofmultislicectusinganthropomorphicheadphantom
AT mehravarrafati dosimetricevaluationofmultislicectusinganthropomorphicheadphantom
AT hamidrezapouraliakbar dosimetricevaluationofmultislicectusinganthropomorphicheadphantom
AT alimohammadzadeh dosimetricevaluationofmultislicectusinganthropomorphicheadphantom