Neuromuscular electrical stimulation for mobility support of elderly

The stimulator for neuromuscular electrical stimulation for mobility support of elderly is not very complicated, but for application within "MOBIL" we have some additional demands to fulfill. First we have specific safety issues for this user group. A powerful compliance management system...

Full description

Bibliographic Details
Main Author: Winfried Mayr
Format: Article
Language:English
Published: PAGEPress Publications 2015-10-01
Series:European Journal of Translational Myology
Subjects:
Online Access:http://www.pagepressjournals.org/index.php/bam/article/view/5605
_version_ 1818063097455181824
author Winfried Mayr
author_facet Winfried Mayr
author_sort Winfried Mayr
collection DOAJ
description The stimulator for neuromuscular electrical stimulation for mobility support of elderly is not very complicated, but for application within "MOBIL" we have some additional demands to fulfill. First we have specific safety issues for this user group. A powerful compliance management system is crucial not only to guide daily application, but for creating hard data for the scientific outcome. We also need to assure easy handling of the stimulator, because the subjects are generally not able to cope with too difficult and complex motor skills. So, we developed five generations of stimulators and optimizing solutions after field tests. We are already planning the sixth generation with wireless control of the stimulation units by the central main handheld control unit. In a prototype, we have implemented a newly available high capacity memory, a breakthrough in “compliance data storage” as they offer the necessary high storage capacity and fast data handling for an affordable prize. The circuit also contains a 3D accelerometer sensor which acts as a further important safety features: if the control unit drops, this event is detected automatically by the sensor and activates an emergency switch-off that disables the stimulation to avoid associated risks. Further, we have implemented a hardware emergence shutdown and other safety measures. Finally, in the last example muscle torque measurements are referenced with compliance data. In the study normalized maximum voluntary contraction (MVC) and maximum stimulation induced contraction (MSC) were assessed in regular check-ups along the training period. With additional consideration of adjusted stimulation intensity for training out of the compliance data records we are able to estimate the induced contraction strength, which turned out to amount in average 11% of MVC. This value may seem on a first sight rather low, and ought to be considered in relation to the results at the end of the training period. Therefore the correlation between normalized MVC and normalized MSC was calculated. It is obvious that MVC can increase to strongly variable extent (3 to 65 %), but in few cases also decrease (-4 to 15 %) over the study period. The correlation suggests that an increase of roughly 1 % of normalized MSC can lead to an increase of about 10 % in MVC in the given training conditions. Overall, we can say that we have a stimulator that has turned out to work sufficiently. The most important feature is the integrated compliance recording because this is very useful for interpretation of the study outcome. The electrical stimulation training has shown that even with relatively small induced contraction intensity we still get some increase in the achievable voluntary extension torque.
first_indexed 2024-12-10T14:14:41Z
format Article
id doaj.art-ad5c2f9301ca413a85a5e98134688222
institution Directory Open Access Journal
issn 2037-7452
2037-7460
language English
last_indexed 2024-12-10T14:14:41Z
publishDate 2015-10-01
publisher PAGEPress Publications
record_format Article
series European Journal of Translational Myology
spelling doaj.art-ad5c2f9301ca413a85a5e981346882222022-12-22T01:45:23ZengPAGEPress PublicationsEuropean Journal of Translational Myology2037-74522037-74602015-10-0125426326810.4081/ejtm.2015.56054511Neuromuscular electrical stimulation for mobility support of elderlyWinfried Mayr0Center of Medical Physics and Biomedical Engineering, Medical University of ViennaThe stimulator for neuromuscular electrical stimulation for mobility support of elderly is not very complicated, but for application within "MOBIL" we have some additional demands to fulfill. First we have specific safety issues for this user group. A powerful compliance management system is crucial not only to guide daily application, but for creating hard data for the scientific outcome. We also need to assure easy handling of the stimulator, because the subjects are generally not able to cope with too difficult and complex motor skills. So, we developed five generations of stimulators and optimizing solutions after field tests. We are already planning the sixth generation with wireless control of the stimulation units by the central main handheld control unit. In a prototype, we have implemented a newly available high capacity memory, a breakthrough in “compliance data storage” as they offer the necessary high storage capacity and fast data handling for an affordable prize. The circuit also contains a 3D accelerometer sensor which acts as a further important safety features: if the control unit drops, this event is detected automatically by the sensor and activates an emergency switch-off that disables the stimulation to avoid associated risks. Further, we have implemented a hardware emergence shutdown and other safety measures. Finally, in the last example muscle torque measurements are referenced with compliance data. In the study normalized maximum voluntary contraction (MVC) and maximum stimulation induced contraction (MSC) were assessed in regular check-ups along the training period. With additional consideration of adjusted stimulation intensity for training out of the compliance data records we are able to estimate the induced contraction strength, which turned out to amount in average 11% of MVC. This value may seem on a first sight rather low, and ought to be considered in relation to the results at the end of the training period. Therefore the correlation between normalized MVC and normalized MSC was calculated. It is obvious that MVC can increase to strongly variable extent (3 to 65 %), but in few cases also decrease (-4 to 15 %) over the study period. The correlation suggests that an increase of roughly 1 % of normalized MSC can lead to an increase of about 10 % in MVC in the given training conditions. Overall, we can say that we have a stimulator that has turned out to work sufficiently. The most important feature is the integrated compliance recording because this is very useful for interpretation of the study outcome. The electrical stimulation training has shown that even with relatively small induced contraction intensity we still get some increase in the achievable voluntary extension torque.http://www.pagepressjournals.org/index.php/bam/article/view/5605AgingSkeletal muscleNeuromuscular electrical stimulation
spellingShingle Winfried Mayr
Neuromuscular electrical stimulation for mobility support of elderly
European Journal of Translational Myology
Aging
Skeletal muscle
Neuromuscular electrical stimulation
title Neuromuscular electrical stimulation for mobility support of elderly
title_full Neuromuscular electrical stimulation for mobility support of elderly
title_fullStr Neuromuscular electrical stimulation for mobility support of elderly
title_full_unstemmed Neuromuscular electrical stimulation for mobility support of elderly
title_short Neuromuscular electrical stimulation for mobility support of elderly
title_sort neuromuscular electrical stimulation for mobility support of elderly
topic Aging
Skeletal muscle
Neuromuscular electrical stimulation
url http://www.pagepressjournals.org/index.php/bam/article/view/5605
work_keys_str_mv AT winfriedmayr neuromuscularelectricalstimulationformobilitysupportofelderly