EFFECT OF ELECTRIC CONDUCTING ELEMENT ON INDICATORS OF LINEAR PULSE ELECTROMECHANICAL CONVERTER INDUCTION TYPE

The purpose of the article is to study the influence of geometric parameters and the location of a coaxially located electrically conductive element (ECE), made in the form of a thin-walled disk, ring or hollow cylinder, on the characteristics and performance of an induction-type linear pulse electr...

Full description

Bibliographic Details
Main Author: В.Ф. Болюх
Format: Article
Language:English
Published: NAS of Ukraine, Institute of elecrodynamics 2020-05-01
Series:Технічна електродинаміка
Subjects:
Online Access:https://techned.org.ua/index.php/techned/article/view/63
_version_ 1818737491219316736
author В.Ф. Болюх
author_facet В.Ф. Болюх
author_sort В.Ф. Болюх
collection DOAJ
description The purpose of the article is to study the influence of geometric parameters and the location of a coaxially located electrically conductive element (ECE), made in the form of a thin-walled disk, ring or hollow cylinder, on the characteristics and performance of an induction-type linear pulse electromechanical converter (LPEC). A mathematical model has been developed that describes the electromechanical and thermal processes in an induction-type LPEC using the concentrated parameters of active elements. It is shown that the ECE, coaxially mounted near the inductor winding, has a negative effect on the performance of the LPEC. The smallest value of the converter efficiency of 6.1% occurs when ECE is used in the form of a thin copper disk 0.5 mm high, in which the radial dimensions are similar to the sizes of the windings of the inductor and the armature installed at a minimum distance from the inductor. Moreover, the temperature rise of the electrically conductive element is maximum and equal to 51°С. With an increase in the thickness of the ECE and with its removal from the inductor, the efficiency of the LPEC increases, and the excess of the temperature of the ECE decreases. When removing a disk ECE with a height of 1.0 mm at a distance of 10 mm from the inductor, the efficiency of the LPEC is 12.6%, and the excess of the ECE temperature is 6 °C. References 14, figures 6.
first_indexed 2024-12-18T00:53:53Z
format Article
id doaj.art-ad694a44bfa44a638cfa438c2616995d
institution Directory Open Access Journal
issn 1607-7970
2218-1903
language English
last_indexed 2024-12-18T00:53:53Z
publishDate 2020-05-01
publisher NAS of Ukraine, Institute of elecrodynamics
record_format Article
series Технічна електродинаміка
spelling doaj.art-ad694a44bfa44a638cfa438c2616995d2022-12-21T21:26:35ZengNAS of Ukraine, Institute of elecrodynamicsТехнічна електродинаміка1607-79702218-19032020-05-01302202210.15407/techned2020.03.02263EFFECT OF ELECTRIC CONDUCTING ELEMENT ON INDICATORS OF LINEAR PULSE ELECTROMECHANICAL CONVERTER INDUCTION TYPEВ.Ф. Болюх0https://orcid.org/0000-0001-9115-7828National Technical University "Kharkiv Polytechnic Institute", st. Kirpicheva, 2, Kharkov, 61002, UkraineThe purpose of the article is to study the influence of geometric parameters and the location of a coaxially located electrically conductive element (ECE), made in the form of a thin-walled disk, ring or hollow cylinder, on the characteristics and performance of an induction-type linear pulse electromechanical converter (LPEC). A mathematical model has been developed that describes the electromechanical and thermal processes in an induction-type LPEC using the concentrated parameters of active elements. It is shown that the ECE, coaxially mounted near the inductor winding, has a negative effect on the performance of the LPEC. The smallest value of the converter efficiency of 6.1% occurs when ECE is used in the form of a thin copper disk 0.5 mm high, in which the radial dimensions are similar to the sizes of the windings of the inductor and the armature installed at a minimum distance from the inductor. Moreover, the temperature rise of the electrically conductive element is maximum and equal to 51°С. With an increase in the thickness of the ECE and with its removal from the inductor, the efficiency of the LPEC increases, and the excess of the temperature of the ECE decreases. When removing a disk ECE with a height of 1.0 mm at a distance of 10 mm from the inductor, the efficiency of the LPEC is 12.6%, and the excess of the ECE temperature is 6 °C. References 14, figures 6.https://techned.org.ua/index.php/techned/article/view/63linear pulse electromechanical converter of induction typeelectrically conductive elementmathematical modelelectromechanical and thermal processes and indicators
spellingShingle В.Ф. Болюх
EFFECT OF ELECTRIC CONDUCTING ELEMENT ON INDICATORS OF LINEAR PULSE ELECTROMECHANICAL CONVERTER INDUCTION TYPE
Технічна електродинаміка
linear pulse electromechanical converter of induction type
electrically conductive element
mathematical model
electromechanical and thermal processes and indicators
title EFFECT OF ELECTRIC CONDUCTING ELEMENT ON INDICATORS OF LINEAR PULSE ELECTROMECHANICAL CONVERTER INDUCTION TYPE
title_full EFFECT OF ELECTRIC CONDUCTING ELEMENT ON INDICATORS OF LINEAR PULSE ELECTROMECHANICAL CONVERTER INDUCTION TYPE
title_fullStr EFFECT OF ELECTRIC CONDUCTING ELEMENT ON INDICATORS OF LINEAR PULSE ELECTROMECHANICAL CONVERTER INDUCTION TYPE
title_full_unstemmed EFFECT OF ELECTRIC CONDUCTING ELEMENT ON INDICATORS OF LINEAR PULSE ELECTROMECHANICAL CONVERTER INDUCTION TYPE
title_short EFFECT OF ELECTRIC CONDUCTING ELEMENT ON INDICATORS OF LINEAR PULSE ELECTROMECHANICAL CONVERTER INDUCTION TYPE
title_sort effect of electric conducting element on indicators of linear pulse electromechanical converter induction type
topic linear pulse electromechanical converter of induction type
electrically conductive element
mathematical model
electromechanical and thermal processes and indicators
url https://techned.org.ua/index.php/techned/article/view/63
work_keys_str_mv AT vfbolûh effectofelectricconductingelementonindicatorsoflinearpulseelectromechanicalconverterinductiontype