Evaluation Scheme of Voltage Sag Immunity in Sensitive Industrial Process
In order to enhance the effectiveness of voltage sag governance and the practicability of the process immunity assessment method, an immunity assessment method for the assembly line process is proposed, fully considering the relationship between logistics line and power line, and thoroughly portrayi...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2021-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/9415635/ |
_version_ | 1811210654718099456 |
---|---|
author | Anjunguo Huang Xianyong Xiao Ying Wang |
author_facet | Anjunguo Huang Xianyong Xiao Ying Wang |
author_sort | Anjunguo Huang |
collection | DOAJ |
description | In order to enhance the effectiveness of voltage sag governance and the practicability of the process immunity assessment method, an immunity assessment method for the assembly line process is proposed, fully considering the relationship between logistics line and power line, and thoroughly portraying the relationship between equipment and its links in depth. Combined with the existing voltage tolerance curve test results, the power line immunity time is reasonably evaluated considering the response delay of each device. In addition, the fault probability is quantified considering the possibility of equipment failure and its link repairing. On this basis, the minimal cut-set method is adapted to standardize the constructed random network of logistics lines. The immunity of the whole manufacturing process is evaluated through series-parallel logical analysis. In the end, the paper mill is taken as a sample to illustrate the proposed method. The deviation between the average annual economic loss obtained from model evaluation and this typical producer’s survey loss is regarded as the basis for the measurement of the effectiveness of the method. The results show that the immunity of the process can be accurately evaluated for the deviation of the evaluation obtained by the proposed method is relatively small. |
first_indexed | 2024-04-12T04:58:28Z |
format | Article |
id | doaj.art-ad88135c9b1340dfb72787be4a124f38 |
institution | Directory Open Access Journal |
issn | 2169-3536 |
language | English |
last_indexed | 2024-04-12T04:58:28Z |
publishDate | 2021-01-01 |
publisher | IEEE |
record_format | Article |
series | IEEE Access |
spelling | doaj.art-ad88135c9b1340dfb72787be4a124f382022-12-22T03:47:03ZengIEEEIEEE Access2169-35362021-01-019663986640710.1109/ACCESS.2021.30754639415635Evaluation Scheme of Voltage Sag Immunity in Sensitive Industrial ProcessAnjunguo Huang0https://orcid.org/0000-0001-6203-4765Xianyong Xiao1Ying Wang2College of Electrical Engineering, Sichuan University, Chengdu, ChinaCollege of Electrical Engineering, Sichuan University, Chengdu, ChinaCollege of Electrical Engineering, Sichuan University, Chengdu, ChinaIn order to enhance the effectiveness of voltage sag governance and the practicability of the process immunity assessment method, an immunity assessment method for the assembly line process is proposed, fully considering the relationship between logistics line and power line, and thoroughly portraying the relationship between equipment and its links in depth. Combined with the existing voltage tolerance curve test results, the power line immunity time is reasonably evaluated considering the response delay of each device. In addition, the fault probability is quantified considering the possibility of equipment failure and its link repairing. On this basis, the minimal cut-set method is adapted to standardize the constructed random network of logistics lines. The immunity of the whole manufacturing process is evaluated through series-parallel logical analysis. In the end, the paper mill is taken as a sample to illustrate the proposed method. The deviation between the average annual economic loss obtained from model evaluation and this typical producer’s survey loss is regarded as the basis for the measurement of the effectiveness of the method. The results show that the immunity of the process can be accurately evaluated for the deviation of the evaluation obtained by the proposed method is relatively small.https://ieeexplore.ieee.org/document/9415635/Voltage sagvoltage tolerance curveprocess immunity timeminimal cut set |
spellingShingle | Anjunguo Huang Xianyong Xiao Ying Wang Evaluation Scheme of Voltage Sag Immunity in Sensitive Industrial Process IEEE Access Voltage sag voltage tolerance curve process immunity time minimal cut set |
title | Evaluation Scheme of Voltage Sag Immunity in Sensitive Industrial Process |
title_full | Evaluation Scheme of Voltage Sag Immunity in Sensitive Industrial Process |
title_fullStr | Evaluation Scheme of Voltage Sag Immunity in Sensitive Industrial Process |
title_full_unstemmed | Evaluation Scheme of Voltage Sag Immunity in Sensitive Industrial Process |
title_short | Evaluation Scheme of Voltage Sag Immunity in Sensitive Industrial Process |
title_sort | evaluation scheme of voltage sag immunity in sensitive industrial process |
topic | Voltage sag voltage tolerance curve process immunity time minimal cut set |
url | https://ieeexplore.ieee.org/document/9415635/ |
work_keys_str_mv | AT anjunguohuang evaluationschemeofvoltagesagimmunityinsensitiveindustrialprocess AT xianyongxiao evaluationschemeofvoltagesagimmunityinsensitiveindustrialprocess AT yingwang evaluationschemeofvoltagesagimmunityinsensitiveindustrialprocess |