Interobserver and Intraobserver Reliability of Cephalometric Measurements Performed on Smartphone-Based Application and Computer-Based Imaging Software: A Comparative Study
Objective:The aim was to compare the reliability of cephalometric analysis using a smartphone-based application with conventional computer-based imaging software.Methods:Pre-treatment cephalometric radiographs of 50 subjects (26 males, 24 females; mean age, 19.2 years; ±4.2) were traced using the On...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Galenos Yayinevi
2023-06-01
|
Series: | Turkish Journal of Orthodontics |
Subjects: | |
Online Access: |
http://www.turkjorthod.org/archives/archive-detail/article-preview/nterobserver-and-ntraobserver-reliability-of-cepha/60380
|
Summary: | Objective:The aim was to compare the reliability of cephalometric analysis using a smartphone-based application with conventional computer-based imaging software.Methods:Pre-treatment cephalometric radiographs of 50 subjects (26 males, 24 females; mean age, 19.2 years; ±4.2) were traced using the OneCeph® application and Dolphin imaging software®. Two independent observers identified seventeen landmarks and measured fourteen cephalometric measurements at an interval of. Interobserver and intraobserver reliability were evaluated using the intraclass correlation coefficient. Student’s t-test was used to compare the means of two measurement methods for observer 1 and observer 2. Additionally, the time taken to complete the cephalometric measurements was also compared between the two methods.Results:Good (ICC 0.75-0.90) to excellent (ICC 0.90-1.00) interobserver and intraobserver reliability was observed for all hard and soft tissue measurements with both methods. No significant differences were found between the two measurement methods for both observers (p<0.05). OneCeph application took significantly more time to complete the analysis than Dolphin imaging software (p<0.001).Conclusion:Cephalometric measurements made through a smartphone-based application showed good to excellent interobserver and intraobserver reliability and are comparable with the computer-based software. Therefore, it can be recommended for clinical use. The time taken to complete the cephalometric measurements was more with a smartphone-based application (OneCeph application) compared to computer-based software (Dolphin imaging software). |
---|---|
ISSN: | 2528-9659 2148-9505 |