A Neuromuscular Electrical Stimulation (NMES) and robot hybrid system for multi-joint coordinated upper limb rehabilitation after stroke

Abstract Background It is a challenge to reduce the muscular discoordination in the paretic upper limb after stroke in the traditional rehabilitation programs. Method In this study, a neuromuscular electrical stimulation (NMES) and robot hybrid system was developed for multi-joint coordinated upper...

Full description

Bibliographic Details
Main Authors: Wei Rong, Waiming Li, Mankit Pang, Junyan Hu, Xijun Wei, Bibo Yang, Honwah Wai, Xiaoxiang Zheng, Xiaoling Hu
Format: Article
Language:English
Published: BMC 2017-04-01
Series:Journal of NeuroEngineering and Rehabilitation
Subjects:
Online Access:http://link.springer.com/article/10.1186/s12984-017-0245-y
Description
Summary:Abstract Background It is a challenge to reduce the muscular discoordination in the paretic upper limb after stroke in the traditional rehabilitation programs. Method In this study, a neuromuscular electrical stimulation (NMES) and robot hybrid system was developed for multi-joint coordinated upper limb physical training. The system could assist the elbow, wrist and fingers to conduct arm reaching out, hand opening/grasping and arm withdrawing by tracking an indicative moving cursor on the screen of a computer, with the support from the joint motors and electrical stimulations on target muscles, under the voluntary intention control by electromyography (EMG). Subjects with chronic stroke (n = 11) were recruited for the investigation on the assistive capability of the NMES-robot and the evaluation of the rehabilitation effectiveness through a 20-session device assisted upper limb training. Results In the evaluation, the movement accuracy measured by the root mean squared error (RMSE) during the tracking was significantly improved with the support from both the robot and NMES, in comparison with those without the assistance from the system (P < 0.05). The intra-joint and inter-joint muscular co-contractions measured by EMG were significantly released when the NMES was applied to the agonist muscles in the different phases of the limb motion (P < 0.05). After the physical training, significant improvements (P < 0.05) were captured by the clinical scores, i.e., Modified Ashworth Score (MAS, the elbow and the wrist), Fugl-Meyer Assessment (FMA), Action Research Arm Test (ARAT), and Wolf Motor Function Test (WMFT). Conclusions The EMG-driven NMES-robotic system could improve the muscular coordination at the elbow, wrist and fingers. Trial registration ClinicalTrials.gov. NCT02117089 ; date of registration: April 10, 2014
ISSN:1743-0003