Comparative Experimental Research on Radiated Noise Characteristics of Straddle Monorail Trains and Metro Trains Passing through Elevated Tracks

[Objective] Radiated noise from urban rail transit has a significant environmental impact. Current research on the radiated noise of metro trains cannot directly guide the external noise control for straddle monorail trains. Therefore, it is necessary to further study the radiated noise characterist...

Full description

Bibliographic Details
Main Authors: Zixue DU, Jian WANG
Format: Article
Language:zho
Published: Urban Mass Transit Magazine Press 2024-02-01
Series:Chengshi guidao jiaotong yanjiu
Subjects:
Online Access:https://umt1998.tongji.edu.cn/journal/paper/doi/10.16037/j.1007-869x.2024.02.035.html
_version_ 1797324494657814528
author Zixue DU
Jian WANG
author_facet Zixue DU
Jian WANG
author_sort Zixue DU
collection DOAJ
description [Objective] Radiated noise from urban rail transit has a significant environmental impact. Current research on the radiated noise of metro trains cannot directly guide the external noise control for straddle monorail trains. Therefore, it is necessary to further study the radiated noise characteristics of straddle monorail trains. [Method] Chongqing Rail Transit Line 1 is taken as the experimental subject for metro train radiated noise, while Chongqing Rail Transit Line 3 is selected for straddle monorail train radiated noise. The study adopts experimental methods to investigate the SPL (sound pressure level) of radiated noise during the operation of staddle monorail trains and metro trains. Measurement points are selected at distances of 7.5 m, 10 m, and 20 m from the center of the track beam, and a comparative analysis is conducted on the SPL at these points under different operating conditions. [Result & Conclusion] The average maximum radiated noise SPL of straddle monorail trains on straight track sections is overall higher than that on curved track sections. It gradually decreases as the distance between measurement points and the center of the track beam increases. Under both straight and curved track conditions, the average maximum radiated noise SPL of straddle monorail trains is 4 to 10 dB(A), lower than that of metro trains.
first_indexed 2024-03-08T05:56:55Z
format Article
id doaj.art-ae11bd92b34a43aba433ac0ce06f0b1a
institution Directory Open Access Journal
issn 1007-869X
language zho
last_indexed 2024-03-08T05:56:55Z
publishDate 2024-02-01
publisher Urban Mass Transit Magazine Press
record_format Article
series Chengshi guidao jiaotong yanjiu
spelling doaj.art-ae11bd92b34a43aba433ac0ce06f0b1a2024-02-05T01:30:07ZzhoUrban Mass Transit Magazine PressChengshi guidao jiaotong yanjiu1007-869X2024-02-0127219119410.16037/j.1007-869x.2024.02.035Comparative Experimental Research on Radiated Noise Characteristics of Straddle Monorail Trains and Metro Trains Passing through Elevated TracksZixue DU0Jian WANG1School of Mechanotronics and Vehicle Engineering, Chongqing Jiaotong University, 400074, Chongqing, ChinaSchool of Mechanotronics and Vehicle Engineering, Chongqing Jiaotong University, 400074, Chongqing, China[Objective] Radiated noise from urban rail transit has a significant environmental impact. Current research on the radiated noise of metro trains cannot directly guide the external noise control for straddle monorail trains. Therefore, it is necessary to further study the radiated noise characteristics of straddle monorail trains. [Method] Chongqing Rail Transit Line 1 is taken as the experimental subject for metro train radiated noise, while Chongqing Rail Transit Line 3 is selected for straddle monorail train radiated noise. The study adopts experimental methods to investigate the SPL (sound pressure level) of radiated noise during the operation of staddle monorail trains and metro trains. Measurement points are selected at distances of 7.5 m, 10 m, and 20 m from the center of the track beam, and a comparative analysis is conducted on the SPL at these points under different operating conditions. [Result & Conclusion] The average maximum radiated noise SPL of straddle monorail trains on straight track sections is overall higher than that on curved track sections. It gradually decreases as the distance between measurement points and the center of the track beam increases. Under both straight and curved track conditions, the average maximum radiated noise SPL of straddle monorail trains is 4 to 10 dB(A), lower than that of metro trains.https://umt1998.tongji.edu.cn/journal/paper/doi/10.16037/j.1007-869x.2024.02.035.htmlstraddle monorailmetroradiated noise
spellingShingle Zixue DU
Jian WANG
Comparative Experimental Research on Radiated Noise Characteristics of Straddle Monorail Trains and Metro Trains Passing through Elevated Tracks
Chengshi guidao jiaotong yanjiu
straddle monorail
metro
radiated noise
title Comparative Experimental Research on Radiated Noise Characteristics of Straddle Monorail Trains and Metro Trains Passing through Elevated Tracks
title_full Comparative Experimental Research on Radiated Noise Characteristics of Straddle Monorail Trains and Metro Trains Passing through Elevated Tracks
title_fullStr Comparative Experimental Research on Radiated Noise Characteristics of Straddle Monorail Trains and Metro Trains Passing through Elevated Tracks
title_full_unstemmed Comparative Experimental Research on Radiated Noise Characteristics of Straddle Monorail Trains and Metro Trains Passing through Elevated Tracks
title_short Comparative Experimental Research on Radiated Noise Characteristics of Straddle Monorail Trains and Metro Trains Passing through Elevated Tracks
title_sort comparative experimental research on radiated noise characteristics of straddle monorail trains and metro trains passing through elevated tracks
topic straddle monorail
metro
radiated noise
url https://umt1998.tongji.edu.cn/journal/paper/doi/10.16037/j.1007-869x.2024.02.035.html
work_keys_str_mv AT zixuedu comparativeexperimentalresearchonradiatednoisecharacteristicsofstraddlemonorailtrainsandmetrotrainspassingthroughelevatedtracks
AT jianwang comparativeexperimentalresearchonradiatednoisecharacteristicsofstraddlemonorailtrainsandmetrotrainspassingthroughelevatedtracks