Dokładnośc badania postawy ciała metodą optoelektroniczną Diers Formetric III 4D w porównaniu z wynikiem zdjęcia RTG = Accuracy of the optoelectronic test body posture Formetric Diers Method III 4D in comparison with the result of the x-ray pictures

Paprocki Michał, Rychter Paweł, Wilczyński Jacek. Dokładnośc badania postawy ciała metodą optoelektroniczną Diers Formetric III 4D w porównaniu z wynikiem zdjęcia RTG = Accuracy of the optoelectronic test body posture Formetric Diers Method III 4D in comparison with the result of the x-ray pictures....

Full description

Bibliographic Details
Main Authors: Michał Jerzy Paprocki, Paweł Rychter, Jacek Wilczyński
Format: Article
Language:English
Published: Kazimierz Wielki University 2016-05-01
Series:Journal of Education, Health and Sport
Subjects:
Online Access:http://www.ojs.ukw.edu.pl/index.php/johs/article/view/3489
_version_ 1818516198597328896
author Michał Jerzy Paprocki
Paweł Rychter
Jacek Wilczyński
author_facet Michał Jerzy Paprocki
Paweł Rychter
Jacek Wilczyński
author_sort Michał Jerzy Paprocki
collection DOAJ
description Paprocki Michał, Rychter Paweł, Wilczyński Jacek. Dokładnośc badania postawy ciała metodą optoelektroniczną Diers Formetric III 4D w porównaniu z wynikiem zdjęcia RTG = Accuracy of the optoelectronic test body posture Formetric Diers Method III 4D in comparison with the result of the x-ray pictures. Journal of Education, Health and Sport. 2016;6(4):385-398. eISSN 2391-8306. DOI http://dx.doi.org/10.5281/zenodo.50535 http://ojs.ukw.edu.pl/index.php/johs/article/view/3489   The journal has had 7 points in Ministry of Science and Higher Education parametric evaluation. Part B item 755 (23.12.2015). 755 Journal of Education, Health and Sport eISSN 2391-8306 7 © The Author (s) 2016; This article is published with open access at Licensee Open Journal Systems of Kazimierz Wielki University in Bydgoszcz, Poland Open Access. This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. This is an open access article licensed under the terms of the Creative Commons Attribution Non Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted, non commercial use, distribution and reproduction in any medium, provided the work is properly cited. This is an open access article licensed under the terms of the Creative Commons Attribution Non Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted, non commercial use, distribution and reproduction in any medium, provided the work is properly cited. The authors declare that there is no conflict of interests regarding the publication of this paper. Received: 05.04.2016. Revised 25.04.2016. Accepted: 27.04.2016.   DOKŁADNOŚC BADANIA POSTAWY CIAŁA METODĄ OPTOELEKTRONICZNĄ DIERS FORMETRIC III 4D W PORÓWNANIU Z WYNIKIEM ZDJĘCIA RTG   Michał Paprocki, Paweł Rychter, Jacek Wilczyński   Instytut fizjoterapii, Uniwersytet Jana Kochanowskiego w Kielcach, Polska   mgr Michał Paprocki mgr Paweł Rychter dr hab. n o k.f. prof. UJK Jacek Wilczyński   Streszczenie Wstęp: Celem przeprowadzonych badań była ocena dokładności badania postawy ciała metodą Diers Formetric III 4D w porównaniu z wynikami zdjęć RTG. Dokonano analizy zdjęcia RTG pacjenta oraz porównano go z wynikiem uzyskanym metodą Diers Formetric III 4D. Materiał i metody: Materiał badawczy stanowił jeden pacjent. Był nim chłopak w wieku lat 16 o wzroście 171cm i wadze 52,5 kg. Pacjent został poddany dwóm badaniom. Pierwsze to zdjęcie RTG całego kręgosłupa natomiast drugie badania zostało wykonane metodą Diers Formetric III 4D. Przed przystąpieniem do leczenia został zebrany wywiad pacjenta. Wyniki: Podsumowując wynik badania Diers Formetric III 4D można stwierdzić, że chłopiec ten miał skoliozę idiopatyczną trzyłukową. Metoda optoelektroniczna Diers formetric III 4D umożliwia szybki, pozbawiony szkodliwego promieniowania i wielkopowierzchniowy optyczny pomiar pleców i kręgosłupa. Porównując wyniki kątów skrzywienia oraz stopnia rotacji w obu badaniach można stwierdzić iż wyniki mieszczą się w błędzie pomiarowym.   Słowa kluczowe: zdjęcie RTG, metoda Cobba, kąt skoliozy, postawa ciał.   Abstract   Introduction: The aim of the study was to assess the accuracy of the testing body posture Formetric Diers method III 4D in comparison with the results of X-RAY images. Analyses x-ray pictures of the patient and compares it with the result obtained by Formetric Diers III 4D. Material and methods: The research Material represented one patient. He is boy at the age of 16 years for growth 171cm and weight 52.5 kg. The patient was subjected to two tests. The first is a radiograph of the entire spine while the second test was done by Formetric Diers III 4D. Before attempting to treat the patient's interview has been harvested. Search results: summing up the result of the test Diers Formetric III 4Dd, it can be concluded that the boy had this three arcs idiopathic scoliosis. Optoelectronic method Diers Formetric III 4D provides fast, devoid of harmful radiation and measuring the optical centres of the back and spine. By comparing the results of the curvature of the angles and the degree of rotation in both studies, it can be concluded that the results are in the measuring error wrong.   Keywords: x-ray, Cobb method, the angle of the scoliosis, attitude.
first_indexed 2024-12-11T00:38:54Z
format Article
id doaj.art-ae3a1f1b5f394182a402c1eea890b2f1
institution Directory Open Access Journal
issn 2391-8306
language English
last_indexed 2024-12-11T00:38:54Z
publishDate 2016-05-01
publisher Kazimierz Wielki University
record_format Article
series Journal of Education, Health and Sport
spelling doaj.art-ae3a1f1b5f394182a402c1eea890b2f12022-12-22T01:27:00ZengKazimierz Wielki UniversityJournal of Education, Health and Sport2391-83062016-05-01643853983306Dokładnośc badania postawy ciała metodą optoelektroniczną Diers Formetric III 4D w porównaniu z wynikiem zdjęcia RTG = Accuracy of the optoelectronic test body posture Formetric Diers Method III 4D in comparison with the result of the x-ray picturesMichał Jerzy Paprocki0Paweł Rychter1Jacek Wilczyński2Instytut fizjoterapii, Uniwersytet Jana Kochanowskiego w KielcachInstytut fizjoterapii, Uniwersytet Jana Kochanowskiego w KielcachInstytut fizjoterapii, Uniwersytet Jana Kochanowskiego w KielcachPaprocki Michał, Rychter Paweł, Wilczyński Jacek. Dokładnośc badania postawy ciała metodą optoelektroniczną Diers Formetric III 4D w porównaniu z wynikiem zdjęcia RTG = Accuracy of the optoelectronic test body posture Formetric Diers Method III 4D in comparison with the result of the x-ray pictures. Journal of Education, Health and Sport. 2016;6(4):385-398. eISSN 2391-8306. DOI http://dx.doi.org/10.5281/zenodo.50535 http://ojs.ukw.edu.pl/index.php/johs/article/view/3489   The journal has had 7 points in Ministry of Science and Higher Education parametric evaluation. Part B item 755 (23.12.2015). 755 Journal of Education, Health and Sport eISSN 2391-8306 7 © The Author (s) 2016; This article is published with open access at Licensee Open Journal Systems of Kazimierz Wielki University in Bydgoszcz, Poland Open Access. This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. This is an open access article licensed under the terms of the Creative Commons Attribution Non Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted, non commercial use, distribution and reproduction in any medium, provided the work is properly cited. This is an open access article licensed under the terms of the Creative Commons Attribution Non Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted, non commercial use, distribution and reproduction in any medium, provided the work is properly cited. The authors declare that there is no conflict of interests regarding the publication of this paper. Received: 05.04.2016. Revised 25.04.2016. Accepted: 27.04.2016.   DOKŁADNOŚC BADANIA POSTAWY CIAŁA METODĄ OPTOELEKTRONICZNĄ DIERS FORMETRIC III 4D W PORÓWNANIU Z WYNIKIEM ZDJĘCIA RTG   Michał Paprocki, Paweł Rychter, Jacek Wilczyński   Instytut fizjoterapii, Uniwersytet Jana Kochanowskiego w Kielcach, Polska   mgr Michał Paprocki mgr Paweł Rychter dr hab. n o k.f. prof. UJK Jacek Wilczyński   Streszczenie Wstęp: Celem przeprowadzonych badań była ocena dokładności badania postawy ciała metodą Diers Formetric III 4D w porównaniu z wynikami zdjęć RTG. Dokonano analizy zdjęcia RTG pacjenta oraz porównano go z wynikiem uzyskanym metodą Diers Formetric III 4D. Materiał i metody: Materiał badawczy stanowił jeden pacjent. Był nim chłopak w wieku lat 16 o wzroście 171cm i wadze 52,5 kg. Pacjent został poddany dwóm badaniom. Pierwsze to zdjęcie RTG całego kręgosłupa natomiast drugie badania zostało wykonane metodą Diers Formetric III 4D. Przed przystąpieniem do leczenia został zebrany wywiad pacjenta. Wyniki: Podsumowując wynik badania Diers Formetric III 4D można stwierdzić, że chłopiec ten miał skoliozę idiopatyczną trzyłukową. Metoda optoelektroniczna Diers formetric III 4D umożliwia szybki, pozbawiony szkodliwego promieniowania i wielkopowierzchniowy optyczny pomiar pleców i kręgosłupa. Porównując wyniki kątów skrzywienia oraz stopnia rotacji w obu badaniach można stwierdzić iż wyniki mieszczą się w błędzie pomiarowym.   Słowa kluczowe: zdjęcie RTG, metoda Cobba, kąt skoliozy, postawa ciał.   Abstract   Introduction: The aim of the study was to assess the accuracy of the testing body posture Formetric Diers method III 4D in comparison with the results of X-RAY images. Analyses x-ray pictures of the patient and compares it with the result obtained by Formetric Diers III 4D. Material and methods: The research Material represented one patient. He is boy at the age of 16 years for growth 171cm and weight 52.5 kg. The patient was subjected to two tests. The first is a radiograph of the entire spine while the second test was done by Formetric Diers III 4D. Before attempting to treat the patient's interview has been harvested. Search results: summing up the result of the test Diers Formetric III 4Dd, it can be concluded that the boy had this three arcs idiopathic scoliosis. Optoelectronic method Diers Formetric III 4D provides fast, devoid of harmful radiation and measuring the optical centres of the back and spine. By comparing the results of the curvature of the angles and the degree of rotation in both studies, it can be concluded that the results are in the measuring error wrong.   Keywords: x-ray, Cobb method, the angle of the scoliosis, attitude.http://www.ojs.ukw.edu.pl/index.php/johs/article/view/3489zdjęcie rtg, metoda cobba, kąt skoliozy, postawa ciał, x-ray, cobb method, the angle of the scoliosis, attitude.
spellingShingle Michał Jerzy Paprocki
Paweł Rychter
Jacek Wilczyński
Dokładnośc badania postawy ciała metodą optoelektroniczną Diers Formetric III 4D w porównaniu z wynikiem zdjęcia RTG = Accuracy of the optoelectronic test body posture Formetric Diers Method III 4D in comparison with the result of the x-ray pictures
Journal of Education, Health and Sport
zdjęcie rtg, metoda cobba, kąt skoliozy, postawa ciał, x-ray, cobb method, the angle of the scoliosis, attitude.
title Dokładnośc badania postawy ciała metodą optoelektroniczną Diers Formetric III 4D w porównaniu z wynikiem zdjęcia RTG = Accuracy of the optoelectronic test body posture Formetric Diers Method III 4D in comparison with the result of the x-ray pictures
title_full Dokładnośc badania postawy ciała metodą optoelektroniczną Diers Formetric III 4D w porównaniu z wynikiem zdjęcia RTG = Accuracy of the optoelectronic test body posture Formetric Diers Method III 4D in comparison with the result of the x-ray pictures
title_fullStr Dokładnośc badania postawy ciała metodą optoelektroniczną Diers Formetric III 4D w porównaniu z wynikiem zdjęcia RTG = Accuracy of the optoelectronic test body posture Formetric Diers Method III 4D in comparison with the result of the x-ray pictures
title_full_unstemmed Dokładnośc badania postawy ciała metodą optoelektroniczną Diers Formetric III 4D w porównaniu z wynikiem zdjęcia RTG = Accuracy of the optoelectronic test body posture Formetric Diers Method III 4D in comparison with the result of the x-ray pictures
title_short Dokładnośc badania postawy ciała metodą optoelektroniczną Diers Formetric III 4D w porównaniu z wynikiem zdjęcia RTG = Accuracy of the optoelectronic test body posture Formetric Diers Method III 4D in comparison with the result of the x-ray pictures
title_sort dokladnosc badania postawy ciala metoda optoelektroniczna diers formetric iii 4d w porownaniu z wynikiem zdjecia rtg accuracy of the optoelectronic test body posture formetric diers method iii 4d in comparison with the result of the x ray pictures
topic zdjęcie rtg, metoda cobba, kąt skoliozy, postawa ciał, x-ray, cobb method, the angle of the scoliosis, attitude.
url http://www.ojs.ukw.edu.pl/index.php/johs/article/view/3489
work_keys_str_mv AT michałjerzypaprocki dokładnoscbadaniapostawyciałametodaoptoelektronicznadiersformetriciii4dwporownaniuzwynikiemzdjeciartgaccuracyoftheoptoelectronictestbodypostureformetricdiersmethodiii4dincomparisonwiththeresultofthexraypictures
AT pawełrychter dokładnoscbadaniapostawyciałametodaoptoelektronicznadiersformetriciii4dwporownaniuzwynikiemzdjeciartgaccuracyoftheoptoelectronictestbodypostureformetricdiersmethodiii4dincomparisonwiththeresultofthexraypictures
AT jacekwilczynski dokładnoscbadaniapostawyciałametodaoptoelektronicznadiersformetriciii4dwporownaniuzwynikiemzdjeciartgaccuracyoftheoptoelectronictestbodypostureformetricdiersmethodiii4dincomparisonwiththeresultofthexraypictures