Vector selection of a quadripolar left ventricular pacing lead affects acute hemodynamic response to cardiac resynchronization therapy: a randomized cross-over trial.

BACKGROUND: A suboptimal left ventricular (LV) pacing site may account for non-responsiveness of patients to cardiac resynchronization therapy (CRT). The vector selection of a novel quadripolar LV pacing lead, which was mainly developed to overcome technical issues with stimulation thresholds and ph...

Full description

Bibliographic Details
Main Authors: Stefan Asbach, Maximilian Hartmann, Tobias Wengenmayer, Erika Graf, Christoph Bode, Juergen Biermann
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2013-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC3691154?pdf=render
_version_ 1818180700792160256
author Stefan Asbach
Maximilian Hartmann
Tobias Wengenmayer
Erika Graf
Christoph Bode
Juergen Biermann
author_facet Stefan Asbach
Maximilian Hartmann
Tobias Wengenmayer
Erika Graf
Christoph Bode
Juergen Biermann
author_sort Stefan Asbach
collection DOAJ
description BACKGROUND: A suboptimal left ventricular (LV) pacing site may account for non-responsiveness of patients to cardiac resynchronization therapy (CRT). The vector selection of a novel quadripolar LV pacing lead, which was mainly developed to overcome technical issues with stimulation thresholds and phrenic nerve capture, may affect hemodynamic response, and was therefore assessed in this study. (German Clinical Trials Register DRKS00000573). METHODS AND RESULTS: Hemodynamic effects of a total of 145 LVPCs (9.1 per patient) of CRT devices with a quadripolar LV lead (Quartet™, St. Jude Medical) were assessed in 16/20 consecutive patients by invasive measurement of LV+dP/dtmax at an invasively optimized AV-interval in random order. Optimal (worst) LVPCs per patient were identified as those with maximal (minimal) %change in LV+dP/dtmax (%ΔLV+dP/dtmax) as compared to a preceding baseline. LV+dP/dtmax significantly increased in all 145 LVPCs (p<0.0001 compared to baseline) with significant intraindividual differences between LVPCs (p<0.0001). Overall, CRT acutely augmented %ΔLV+dP/dtmax by 31.3% (95% CI 24%-39%) in the optimal, by 21.3% (95% CI: 15%-27%) in the worst and by 28.2% (95% CI: 21%-36%) in a default distal LVPC. This resulted in an absolute additional acute increase in %ΔLV+dP/dtmax of 10.0% (95% CI: 7%-13%) of the optimal when compared to the worst (p<0.0001), and of 3.1% (95% CI: 1%-5%) of the optimal when compared to the default distal LVPC (p<0.001). Optimal LVPCs were not programmable with a standard bipolar lead in 44% (7/16) of patients. CONCLUSION: The pacing configuration of a quadripolar LV lead determinates acute hemodynamic response. Pacing in the individually optimized configuration gives rise to an additional absolute 10% increase in %ΔLV+dP/dtmax when comparing optimal and worst vectors.
first_indexed 2024-12-11T21:23:56Z
format Article
id doaj.art-ae89b285c8e0457ebdd24b1e6610cbf1
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-11T21:23:56Z
publishDate 2013-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-ae89b285c8e0457ebdd24b1e6610cbf12022-12-22T00:50:24ZengPublic Library of Science (PLoS)PLoS ONE1932-62032013-01-0186e6723510.1371/journal.pone.0067235Vector selection of a quadripolar left ventricular pacing lead affects acute hemodynamic response to cardiac resynchronization therapy: a randomized cross-over trial.Stefan AsbachMaximilian HartmannTobias WengenmayerErika GrafChristoph BodeJuergen BiermannBACKGROUND: A suboptimal left ventricular (LV) pacing site may account for non-responsiveness of patients to cardiac resynchronization therapy (CRT). The vector selection of a novel quadripolar LV pacing lead, which was mainly developed to overcome technical issues with stimulation thresholds and phrenic nerve capture, may affect hemodynamic response, and was therefore assessed in this study. (German Clinical Trials Register DRKS00000573). METHODS AND RESULTS: Hemodynamic effects of a total of 145 LVPCs (9.1 per patient) of CRT devices with a quadripolar LV lead (Quartet™, St. Jude Medical) were assessed in 16/20 consecutive patients by invasive measurement of LV+dP/dtmax at an invasively optimized AV-interval in random order. Optimal (worst) LVPCs per patient were identified as those with maximal (minimal) %change in LV+dP/dtmax (%ΔLV+dP/dtmax) as compared to a preceding baseline. LV+dP/dtmax significantly increased in all 145 LVPCs (p<0.0001 compared to baseline) with significant intraindividual differences between LVPCs (p<0.0001). Overall, CRT acutely augmented %ΔLV+dP/dtmax by 31.3% (95% CI 24%-39%) in the optimal, by 21.3% (95% CI: 15%-27%) in the worst and by 28.2% (95% CI: 21%-36%) in a default distal LVPC. This resulted in an absolute additional acute increase in %ΔLV+dP/dtmax of 10.0% (95% CI: 7%-13%) of the optimal when compared to the worst (p<0.0001), and of 3.1% (95% CI: 1%-5%) of the optimal when compared to the default distal LVPC (p<0.001). Optimal LVPCs were not programmable with a standard bipolar lead in 44% (7/16) of patients. CONCLUSION: The pacing configuration of a quadripolar LV lead determinates acute hemodynamic response. Pacing in the individually optimized configuration gives rise to an additional absolute 10% increase in %ΔLV+dP/dtmax when comparing optimal and worst vectors.http://europepmc.org/articles/PMC3691154?pdf=render
spellingShingle Stefan Asbach
Maximilian Hartmann
Tobias Wengenmayer
Erika Graf
Christoph Bode
Juergen Biermann
Vector selection of a quadripolar left ventricular pacing lead affects acute hemodynamic response to cardiac resynchronization therapy: a randomized cross-over trial.
PLoS ONE
title Vector selection of a quadripolar left ventricular pacing lead affects acute hemodynamic response to cardiac resynchronization therapy: a randomized cross-over trial.
title_full Vector selection of a quadripolar left ventricular pacing lead affects acute hemodynamic response to cardiac resynchronization therapy: a randomized cross-over trial.
title_fullStr Vector selection of a quadripolar left ventricular pacing lead affects acute hemodynamic response to cardiac resynchronization therapy: a randomized cross-over trial.
title_full_unstemmed Vector selection of a quadripolar left ventricular pacing lead affects acute hemodynamic response to cardiac resynchronization therapy: a randomized cross-over trial.
title_short Vector selection of a quadripolar left ventricular pacing lead affects acute hemodynamic response to cardiac resynchronization therapy: a randomized cross-over trial.
title_sort vector selection of a quadripolar left ventricular pacing lead affects acute hemodynamic response to cardiac resynchronization therapy a randomized cross over trial
url http://europepmc.org/articles/PMC3691154?pdf=render
work_keys_str_mv AT stefanasbach vectorselectionofaquadripolarleftventricularpacingleadaffectsacutehemodynamicresponsetocardiacresynchronizationtherapyarandomizedcrossovertrial
AT maximilianhartmann vectorselectionofaquadripolarleftventricularpacingleadaffectsacutehemodynamicresponsetocardiacresynchronizationtherapyarandomizedcrossovertrial
AT tobiaswengenmayer vectorselectionofaquadripolarleftventricularpacingleadaffectsacutehemodynamicresponsetocardiacresynchronizationtherapyarandomizedcrossovertrial
AT erikagraf vectorselectionofaquadripolarleftventricularpacingleadaffectsacutehemodynamicresponsetocardiacresynchronizationtherapyarandomizedcrossovertrial
AT christophbode vectorselectionofaquadripolarleftventricularpacingleadaffectsacutehemodynamicresponsetocardiacresynchronizationtherapyarandomizedcrossovertrial
AT juergenbiermann vectorselectionofaquadripolarleftventricularpacingleadaffectsacutehemodynamicresponsetocardiacresynchronizationtherapyarandomizedcrossovertrial